diff options
author | Vadim Yanitskiy <vyanitskiy@sysmocom.de> | 2021-01-06 01:32:17 +0100 |
---|---|---|
committer | fixeria <vyanitskiy@sysmocom.de> | 2021-01-07 00:38:55 +0000 |
commit | 22646cb122c06e12c2487184619d89047c9681aa (patch) | |
tree | 4e4c863c55fc831cfdac111e5347af600827d672 | |
parent | major README uppdate (diff) | |
download | OsmoBTS-22646cb122c06e12c2487184619d89047c9681aa.tar.xz OsmoBTS-22646cb122c06e12c2487184619d89047c9681aa.zip |
osmo-bts-trx: vty: clarify and improve some deprecation messages
Change-Id: I22b69eccfa50d178bd36bf770f7158ec441c9923
Related: SYS#4918
-rw-r--r-- | src/osmo-bts-trx/trx_vty.c | 12 |
1 files changed, 8 insertions, 4 deletions
diff --git a/src/osmo-bts-trx/trx_vty.c b/src/osmo-bts-trx/trx_vty.c index 55a7ee7c..49403d4e 100644 --- a/src/osmo-bts-trx/trx_vty.c +++ b/src/osmo-bts-trx/trx_vty.c @@ -196,7 +196,8 @@ DEFUN_DEPRECATED(cfg_phy_ms_power_loop, cfg_phy_ms_power_loop_cmd, "Enable MS power control loop\nTarget RSSI value (transceiver specific, " "should be 6dB or more above noise floor)\n") { - vty_out (vty, "'osmotrx ms-power-loop' is deprecated, use 'uplink-power-target' instead%s", VTY_NEWLINE); + vty_out(vty, "'%s' is deprecated, MS Power Control is now managed by BSC%s", + self->string, VTY_NEWLINE); g_bts->ul_power_ctrl.target_dbm = atoi(argv[0]); @@ -207,7 +208,8 @@ DEFUN_DEPRECATED(cfg_phy_no_ms_power_loop, cfg_phy_no_ms_power_loop_cmd, "no osmotrx ms-power-loop", NO_STR OSMOTRX_STR "Disable MS power control loop\n") { - vty_out (vty, "'no osmotrx ms-power-loop' is deprecated, use of BTS control loop is managed by BSC%s", VTY_NEWLINE); + vty_out(vty, "'%s' is deprecated, MS Power Control is now managed by BSC%s", + self->string, VTY_NEWLINE); return CMD_SUCCESS; } @@ -216,7 +218,8 @@ DEFUN_DEPRECATED(cfg_phy_timing_advance_loop, cfg_phy_timing_advance_loop_cmd, "osmotrx timing-advance-loop", OSMOTRX_STR "Enable timing advance control loop\n") { - vty_out (vty, "'osmotrx timing-advance-loop' is deprecated, ta control is now active by default%s", VTY_NEWLINE); + vty_out(vty, "'%s' is deprecated, Timing Advance loop is now active by default%s", + self->string, VTY_NEWLINE); return CMD_SUCCESS; } @@ -224,7 +227,8 @@ DEFUN_DEPRECATED(cfg_phy_no_timing_advance_loop, cfg_phy_no_timing_advance_loop_ "no osmotrx timing-advance-loop", NO_STR OSMOTRX_STR "Disable timing advance control loop\n") { - vty_out (vty, "'no osmotrx timing-advance-loop' is deprecated, ta control is now active by default%s", VTY_NEWLINE); + vty_out(vty, "'%s' is deprecated, Timing Advance loop is now active by default%s", + self->string, VTY_NEWLINE); return CMD_SUCCESS; } |