aboutsummaryrefslogtreecommitdiffstats
path: root/tests/power/bs_power_loop_test.err
blob: c3fb8167fce3b7b2ef351b06a267909d7b76a6ab (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 0 -> 2 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 2 -> 4 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 4 -> 6 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 6 -> 8 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 8 -> 10 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 10 -> 12 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 12 -> 14 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 14 -> 16 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 16 -> 18 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 18 -> 20 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 20 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 20 dB (maximum 20 dB, delta 2 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 20 -> 16 dB (maximum 20 dB, delta -4 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 16 -> 12 dB (maximum 20 dB, delta -4 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 12 -> 8 dB (maximum 20 dB, delta -4 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 8 -> 4 dB (maximum 20 dB, delta -4 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 4 -> 0 dB (maximum 20 dB, delta -4 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta -4 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta -4 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 0 -> 4 dB (maximum 20 dB, delta 4 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 4 -> 8 dB (maximum 20 dB, delta 4 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 8 -> 12 dB (maximum 20 dB, delta 4 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 12 -> 16 dB (maximum 20 dB, delta 4 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 16 -> 20 dB (maximum 20 dB, delta 4 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(60), RXQUAL-FULL(0), RXLEV-SUB(60), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 20 dB (maximum 20 dB, delta 4 dB, RxLev current 60 (-50 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 20 -> 14 dB (maximum 20 dB, delta -6 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 14 -> 8 dB (maximum 20 dB, delta -6 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 8 -> 2 dB (maximum 20 dB, delta -6 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 2 -> 0 dB (maximum 20 dB, delta -6 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(10), RXQUAL-FULL(0), RXLEV-SUB(10), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta -6 dB, RxLev current 10 (-100 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(31), RXQUAL-FULL(0), RXLEV-SUB(31), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 10 -> 11 dB (maximum 20 dB, delta 1 dB, RxLev current 31 (-79 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 11 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(32), RXQUAL-FULL(0), RXLEV-SUB(32), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 11 -> 13 dB (maximum 20 dB, delta 2 dB, RxLev current 32 (-78 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 13 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(33), RXQUAL-FULL(0), RXLEV-SUB(33), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 13 -> 16 dB (maximum 20 dB, delta 3 dB, RxLev current 33 (-77 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(29), RXQUAL-FULL(0), RXLEV-SUB(29), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 10 -> 9 dB (maximum 20 dB, delta -1 dB, RxLev current 29 (-81 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 9 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(27), RXQUAL-FULL(0), RXLEV-SUB(27), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 9 -> 6 dB (maximum 20 dB, delta -3 dB, RxLev current 27 (-83 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 6 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(25), RXQUAL-FULL(0), RXLEV-SUB(25), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 6 -> 1 dB (maximum 20 dB, delta -5 dB, RxLev current 25 (-85 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 1 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(00), RXQUAL-FULL(7), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is enabled => using SUB
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(3), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is enabled => using SUB
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(63), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is enabled => using SUB
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 0 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(1), RXLEV-SUB(30), RXQUAL-SUB(1), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(2), RXLEV-SUB(30), RXQUAL-SUB(2), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(3), RXLEV-SUB(30), RXQUAL-SUB(3), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(4), RXLEV-SUB(30), RXQUAL-SUB(4), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Reducing Downlink attenuation: 16 -> 12 dB due to RxQual 4 worse than L_RXQUAL_XX_P 3
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(34), RXQUAL-FULL(5), RXLEV-SUB(34), RXQUAL-SUB(5), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Reducing Downlink attenuation: 12 -> 8 dB due to RxQual 5 worse than L_RXQUAL_XX_P 3
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(38), RXQUAL-FULL(6), RXLEV-SUB(38), RXQUAL-SUB(6), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Reducing Downlink attenuation: 8 -> 4 dB due to RxQual 6 worse than L_RXQUAL_XX_P 3
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(42), RXQUAL-FULL(7), RXLEV-SUB(42), RXQUAL-SUB(7), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Reducing Downlink attenuation: 4 -> 0 dB due to RxQual 7 worse than L_RXQUAL_XX_P 3
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(46), RXQUAL-FULL(7), RXLEV-SUB(46), RXQUAL-SUB(7), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(46), RXQUAL-FULL(0), RXLEV-SUB(46), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 0 -> 2 dB (maximum 20 dB, delta 2 dB, RxLev current 46 (-64 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(44), RXQUAL-FULL(0), RXLEV-SUB(44), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 2 -> 4 dB (maximum 20 dB, delta 2 dB, RxLev current 44 (-66 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(42), RXQUAL-FULL(0), RXLEV-SUB(42), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 4 -> 6 dB (maximum 20 dB, delta 2 dB, RxLev current 42 (-68 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(7), RXLEV-SUB(30), RXQUAL-SUB(7), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(7), RXLEV-SUB(30), RXQUAL-SUB(7), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) The measurement results are not valid
(bts=0,trx=0,ts=0,ss=0) The measurement results are not valid
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 20 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(31), RXQUAL-FULL(0), RXLEV-SUB(31), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 12 -> 13 dB (maximum 16 dB, delta 1 dB, RxLev current 31 (-79 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(28), RXQUAL-FULL(0), RXLEV-SUB(28), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 13 -> 11 dB (maximum 16 dB, delta -2 dB, RxLev current 28 (-82 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(33), RXQUAL-FULL(0), RXLEV-SUB(33), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 11 -> 13 dB (maximum 16 dB, delta 2 dB, RxLev current 33 (-77 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(28), RXQUAL-FULL(0), RXLEV-SUB(28), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 13 -> 11 dB (maximum 16 dB, delta -2 dB, RxLev current 28 (-82 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(31), RXQUAL-FULL(0), RXLEV-SUB(31), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 11 dB (maximum 16 dB, delta 0 dB, RxLev current 31 (-79 dBm), thresholds 27 .. 33)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(28), RXQUAL-FULL(0), RXLEV-SUB(28), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 11 dB (maximum 16 dB, delta 0 dB, RxLev current 28 (-82 dBm), thresholds 27 .. 33)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(33), RXQUAL-FULL(0), RXLEV-SUB(33), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 11 dB (maximum 16 dB, delta 0 dB, RxLev current 33 (-77 dBm), thresholds 27 .. 33)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(28), RXQUAL-FULL(0), RXLEV-SUB(28), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 11 dB (maximum 16 dB, delta 0 dB, RxLev current 28 (-82 dBm), thresholds 27 .. 33)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 30 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(30), RXQUAL-FULL(0), RXLEV-SUB(30), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Keeping Downlink attenuation at 16 dB (maximum 30 dB, delta 0 dB, RxLev current 30 (-80 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(26), RXQUAL-FULL(0), RXLEV-SUB(26), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 16 -> 14 dB (maximum 30 dB, delta -2 dB, RxLev current 26 (-84 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(26), RXQUAL-FULL(0), RXLEV-SUB(26), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 14 -> 11 dB (maximum 30 dB, delta -3 dB, RxLev current 26 (-84 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(35), RXQUAL-FULL(0), RXLEV-SUB(35), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 11 -> 12 dB (maximum 30 dB, delta 1 dB, RxLev current 35 (-75 dBm), thresholds 30 .. 30)
(bts=0,trx=0,ts=0,ss=0) Rx DL Measurement Report: RXLEV-FULL(35), RXQUAL-FULL(0), RXLEV-SUB(35), RXQUAL-SUB(0), DTx is disabled => using FULL
(bts=0,trx=0,ts=0,ss=0) Changing Downlink attenuation: 12 -> 14 dB (maximum 30 dB, delta 2 dB, RxLev current 35 (-75 dBm), thresholds 30 .. 30)