aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
diff options
context:
space:
mode:
authorBarak Witkowski <barak@broadcom.com>2012-12-05 23:04:03 +0000
committerDavid S. Miller <davem@davemloft.net>2012-12-07 12:53:49 -0500
commitc63da990cd63153ce5203f96822638a7ef0f9bf7 (patch)
treeff99d59bf8d08e978acc6aef42c0d684613689bc /drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
parentnet: phy: smsc: force all capable mode if the phy is started in powerdown mode (diff)
downloadlinux-dev-c63da990cd63153ce5203f96822638a7ef0f9bf7.tar.xz
linux-dev-c63da990cd63153ce5203f96822638a7ef0f9bf7.zip
bnx2x: Prevent link flaps when booting from SAN.
It is possible that the driver is configured to operate with a certain link configuration which differs from the link's configuration during boot from SAN - this would cause the driver to flap the link. Said flap may be missed by specific switches, causing dcbx convergence to be too long and boot sequence to fail. Convergence is longer because switch ignores new dcbx packets due to counters mismatch, as only host side reset the counters due to the link flap. This patch causes the driver to ignore user's initial configuration during boot from SAN, and continues with the existing link configuration. Signed-off-by: Barak Witkowski <barak@broadcom.com> Signed-off-by: Yuval Mintz <yuvalmin@broadcom.com> Signed-off-by: Eilon Greenstein <eilong@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to '')
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c28
1 files changed, 25 insertions, 3 deletions
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
index f34ff59a8095..2f6a19bfad5a 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
@@ -9515,6 +9515,20 @@ static int bnx2x_prev_mcp_done(struct bnx2x *bp)
return 0;
}
+static struct bnx2x_prev_path_list *
+ bnx2x_prev_path_get_entry(struct bnx2x *bp)
+{
+ struct bnx2x_prev_path_list *tmp_list;
+
+ list_for_each_entry(tmp_list, &bnx2x_prev_list, list)
+ if (PCI_SLOT(bp->pdev->devfn) == tmp_list->slot &&
+ bp->pdev->bus->number == tmp_list->bus &&
+ BP_PATH(bp) == tmp_list->path)
+ return tmp_list;
+
+ return NULL;
+}
+
static bool bnx2x_prev_is_path_marked(struct bnx2x *bp)
{
struct bnx2x_prev_path_list *tmp_list;
@@ -9539,7 +9553,7 @@ static bool bnx2x_prev_is_path_marked(struct bnx2x *bp)
return rc;
}
-static int bnx2x_prev_mark_path(struct bnx2x *bp)
+static int bnx2x_prev_mark_path(struct bnx2x *bp, bool after_undi)
{
struct bnx2x_prev_path_list *tmp_list;
int rc;
@@ -9553,6 +9567,7 @@ static int bnx2x_prev_mark_path(struct bnx2x *bp)
tmp_list->bus = bp->pdev->bus->number;
tmp_list->slot = PCI_SLOT(bp->pdev->devfn);
tmp_list->path = BP_PATH(bp);
+ tmp_list->undi = after_undi ? (1 << BP_PORT(bp)) : 0;
rc = down_interruptible(&bnx2x_prev_sem);
if (rc) {
@@ -9649,6 +9664,7 @@ static int bnx2x_prev_unload_uncommon(struct bnx2x *bp)
static int bnx2x_prev_unload_common(struct bnx2x *bp)
{
u32 reset_reg, tmp_reg = 0, rc;
+ bool prev_undi = false;
/* It is possible a previous function received 'common' answer,
* but hasn't loaded yet, therefore creating a scenario of
* multiple functions receiving 'common' on the same path.
@@ -9663,7 +9679,6 @@ static int bnx2x_prev_unload_common(struct bnx2x *bp)
/* Reset should be performed after BRB is emptied */
if (reset_reg & MISC_REGISTERS_RESET_REG_1_RST_BRB1) {
u32 timer_count = 1000;
- bool prev_undi = false;
/* Close the MAC Rx to prevent BRB from filling up */
bnx2x_prev_unload_close_mac(bp);
@@ -9713,7 +9728,7 @@ static int bnx2x_prev_unload_common(struct bnx2x *bp)
/* No packets are in the pipeline, path is ready for reset */
bnx2x_reset_common(bp);
- rc = bnx2x_prev_mark_path(bp);
+ rc = bnx2x_prev_mark_path(bp, prev_undi);
if (rc) {
bnx2x_prev_mcp_done(bp);
return rc;
@@ -9745,6 +9760,7 @@ static int bnx2x_prev_unload(struct bnx2x *bp)
{
int time_counter = 10;
u32 rc, fw, hw_lock_reg, hw_lock_val;
+ struct bnx2x_prev_path_list *prev_list;
BNX2X_DEV_INFO("Entering Previous Unload Flow\n");
/* clear hw from errors which may have resulted from an interrupted
@@ -9803,6 +9819,12 @@ static int bnx2x_prev_unload(struct bnx2x *bp)
rc = -EBUSY;
}
+ /* Mark function if its port was used to boot from SAN */
+ prev_list = bnx2x_prev_path_get_entry(bp);
+ if (prev_list && (prev_list->undi & (1 << BP_PORT(bp))))
+ bp->link_params.feature_config_flags |=
+ FEATURE_CONFIG_BOOT_FROM_SAN;
+
BNX2X_DEV_INFO("Finished Previous Unload Flow [%d]\n", rc);
return rc;