aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/emulex/benet/be_main.c
diff options
context:
space:
mode:
authorSuresh Reddy <suresh.reddy@broadcom.com>2016-06-06 07:22:08 -0400
committerDavid S. Miller <davem@davemloft.net>2016-06-07 16:18:19 -0700
commitb9263cbf217433c1249c7341f8c0a9b4a5df6753 (patch)
tree223b328f8568682b2367a17968a82768dad261fa /drivers/net/ethernet/emulex/benet/be_main.c
parentdrivers/net: support hdlc function for QE-UCC (diff)
downloadlinux-dev-b9263cbf217433c1249c7341f8c0a9b4a5df6753.tar.xz
linux-dev-b9263cbf217433c1249c7341f8c0a9b4a5df6753.zip
be2net: use max-TXQs limit too while provisioning VF queue pairs
When the PF driver provisions resources for VFs, it currently only looks at max RSS queues available to calculate the number of VF queue pairs. This logic breaks when there are less number of TX-queues than RSS-queues. This patch fixes this problem by using the max-TXQs available in the PF-pool in the calculations. As a part of this change the be_calculate_vf_qs() routine is renamed as be_calculate_vf_res() and the code that calculates limits on other related resources is moved here to contain all resource calculation code inside one routine. Signed-off-by: Suresh Reddy <suresh.reddy@broadcom.com> Signed-off-by: Sathya Perla <sathya.perla@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to '')
-rw-r--r--drivers/net/ethernet/emulex/benet/be_main.c82
1 files changed, 68 insertions, 14 deletions
diff --git a/drivers/net/ethernet/emulex/benet/be_main.c b/drivers/net/ethernet/emulex/benet/be_main.c
index ed98ef1ecac3..860104711ce7 100644
--- a/drivers/net/ethernet/emulex/benet/be_main.c
+++ b/drivers/net/ethernet/emulex/benet/be_main.c
@@ -3810,17 +3810,20 @@ static void be_disable_vxlan_offloads(struct be_adapter *adapter)
}
#endif
-static u16 be_calculate_vf_qs(struct be_adapter *adapter, u16 num_vfs)
+static void be_calculate_vf_res(struct be_adapter *adapter, u16 num_vfs,
+ struct be_resources *vft_res)
{
struct be_resources res = adapter->pool_res;
+ u32 vf_if_cap_flags = res.vf_if_cap_flags;
+ struct be_resources res_mod = {0};
u16 num_vf_qs = 1;
/* Distribute the queue resources among the PF and it's VFs
* Do not distribute queue resources in multi-channel configuration.
*/
if (num_vfs && !be_is_mc(adapter)) {
- /* Divide the qpairs evenly among the VFs and the PF, capped
- * at VF-EQ-count. Any remainder qpairs belong to the PF.
+ /* Divide the rx queues evenly among the VFs and the PF, capped
+ * at VF-EQ-count. Any remainder queues belong to the PF.
*/
num_vf_qs = min(SH_VF_MAX_NIC_EQS,
res.max_rss_qs / (num_vfs + 1));
@@ -3832,13 +3835,62 @@ static u16 be_calculate_vf_qs(struct be_adapter *adapter, u16 num_vfs)
if (num_vfs >= MAX_RSS_IFACES)
num_vf_qs = 1;
}
- return num_vf_qs;
+
+ /* Resource with fields set to all '1's by GET_PROFILE_CONFIG cmd,
+ * which are modifiable using SET_PROFILE_CONFIG cmd.
+ */
+ be_cmd_get_profile_config(adapter, &res_mod, RESOURCE_MODIFIABLE, 0);
+
+ /* If RSS IFACE capability flags are modifiable for a VF, set the
+ * capability flag as valid and set RSS and DEFQ_RSS IFACE flags if
+ * more than 1 RSSQ is available for a VF.
+ * Otherwise, provision only 1 queue pair for VF.
+ */
+ if (res_mod.vf_if_cap_flags & BE_IF_FLAGS_RSS) {
+ vft_res->flags |= BIT(IF_CAPS_FLAGS_VALID_SHIFT);
+ if (num_vf_qs > 1) {
+ vf_if_cap_flags |= BE_IF_FLAGS_RSS;
+ if (res.if_cap_flags & BE_IF_FLAGS_DEFQ_RSS)
+ vf_if_cap_flags |= BE_IF_FLAGS_DEFQ_RSS;
+ } else {
+ vf_if_cap_flags &= ~(BE_IF_FLAGS_RSS |
+ BE_IF_FLAGS_DEFQ_RSS);
+ }
+ } else {
+ num_vf_qs = 1;
+ }
+
+ if (res_mod.vf_if_cap_flags & BE_IF_FLAGS_VLAN_PROMISCUOUS) {
+ vft_res->flags |= BIT(IF_CAPS_FLAGS_VALID_SHIFT);
+ vf_if_cap_flags &= ~BE_IF_FLAGS_VLAN_PROMISCUOUS;
+ }
+
+ vft_res->vf_if_cap_flags = vf_if_cap_flags;
+ vft_res->max_rx_qs = num_vf_qs;
+ vft_res->max_rss_qs = num_vf_qs;
+ vft_res->max_tx_qs = res.max_tx_qs / (num_vfs + 1);
+ vft_res->max_cq_count = res.max_cq_count / (num_vfs + 1);
+
+ /* Distribute unicast MACs, VLANs, IFACE count and MCCQ count equally
+ * among the PF and it's VFs, if the fields are changeable
+ */
+ if (res_mod.max_uc_mac == FIELD_MODIFIABLE)
+ vft_res->max_uc_mac = res.max_uc_mac / (num_vfs + 1);
+
+ if (res_mod.max_vlans == FIELD_MODIFIABLE)
+ vft_res->max_vlans = res.max_vlans / (num_vfs + 1);
+
+ if (res_mod.max_iface_count == FIELD_MODIFIABLE)
+ vft_res->max_iface_count = res.max_iface_count / (num_vfs + 1);
+
+ if (res_mod.max_mcc_count == FIELD_MODIFIABLE)
+ vft_res->max_mcc_count = res.max_mcc_count / (num_vfs + 1);
}
static int be_clear(struct be_adapter *adapter)
{
struct pci_dev *pdev = adapter->pdev;
- u16 num_vf_qs;
+ struct be_resources vft_res = {0};
be_cancel_worker(adapter);
@@ -3850,11 +3902,12 @@ static int be_clear(struct be_adapter *adapter)
*/
if (skyhawk_chip(adapter) && be_physfn(adapter) &&
!pci_vfs_assigned(pdev)) {
- num_vf_qs = be_calculate_vf_qs(adapter,
- pci_sriov_get_totalvfs(pdev));
+ be_calculate_vf_res(adapter,
+ pci_sriov_get_totalvfs(pdev),
+ &vft_res);
be_cmd_set_sriov_config(adapter, adapter->pool_res,
pci_sriov_get_totalvfs(pdev),
- num_vf_qs);
+ &vft_res);
}
#ifdef CONFIG_BE2NET_VXLAN
@@ -4144,7 +4197,7 @@ static int be_get_sriov_config(struct be_adapter *adapter)
static void be_alloc_sriov_res(struct be_adapter *adapter)
{
int old_vfs = pci_num_vf(adapter->pdev);
- u16 num_vf_qs;
+ struct be_resources vft_res = {0};
int status;
be_get_sriov_config(adapter);
@@ -4158,9 +4211,9 @@ static void be_alloc_sriov_res(struct be_adapter *adapter)
* Also, this is done by FW in Lancer chip.
*/
if (skyhawk_chip(adapter) && be_max_vfs(adapter) && !old_vfs) {
- num_vf_qs = be_calculate_vf_qs(adapter, 0);
+ be_calculate_vf_res(adapter, 0, &vft_res);
status = be_cmd_set_sriov_config(adapter, adapter->pool_res, 0,
- num_vf_qs);
+ &vft_res);
if (status)
dev_err(&adapter->pdev->dev,
"Failed to optimize SRIOV resources\n");
@@ -5552,7 +5605,7 @@ err:
static int be_pci_sriov_configure(struct pci_dev *pdev, int num_vfs)
{
struct be_adapter *adapter = pci_get_drvdata(pdev);
- u16 num_vf_qs;
+ struct be_resources vft_res = {0};
int status;
if (!num_vfs)
@@ -5575,9 +5628,10 @@ static int be_pci_sriov_configure(struct pci_dev *pdev, int num_vfs)
* Also, this is done by FW in Lancer chip.
*/
if (skyhawk_chip(adapter) && !pci_num_vf(pdev)) {
- num_vf_qs = be_calculate_vf_qs(adapter, adapter->num_vfs);
+ be_calculate_vf_res(adapter, adapter->num_vfs,
+ &vft_res);
status = be_cmd_set_sriov_config(adapter, adapter->pool_res,
- adapter->num_vfs, num_vf_qs);
+ adapter->num_vfs, &vft_res);
if (status)
dev_err(&pdev->dev,
"Failed to optimize SR-IOV resources\n");