aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-bus-iio-sx9324
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-sx932429
1 files changed, 29 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-sx9324 b/Documentation/ABI/testing/sysfs-bus-iio-sx9324
new file mode 100644
index 000000000000..a8342770e7cb
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-sx9324
@@ -0,0 +1,29 @@
+What: /sys/bus/iio/devices/iio:deviceX/in_proximity<id>_setup
+Date: November 2021
+KernelVersion: 5.17
+Contact: Gwendal Grignou <gwendal@chromium.org>
+Description:
+ SX9324 has 3 inputs, CS0, CS1 and CS2. Hardware layout
+ defines if the input is
+
+ + not connected (HZ),
+ + grounded (GD),
+ + connected to an antenna where it can act as a base
+ (DS - data shield), or measured input (MI).
+
+ The sensor rotates measurement across 4 phases
+ (PH0, PH1, PH2, PH3), where the inputs are configured
+ and then measured.
+
+ By default, during the first phase, [PH0], CS0 is measured,
+ while CS1 and CS2 are used as shields.
+ `cat in_proximity0_setup` returns "MI,DS,DS".
+ [PH1], CS1 is measured, CS0 and CS2 are shield:
+ `cat in_proximity1_setup` returns "DS,MI,DS".
+ [PH2], CS2 is measured, CS0 and CS1 are shield:
+ `cat in_proximity1_setup` returns "DS,DS,MI".
+ [PH3], CS1 and CS2 are measured (combo mode):
+ `cat in_proximity1_setup` returns "DS,MI,MI".
+
+ Note, these are the chip default. Hardware layout will most
+ likely dictate different output. The entry is read-only.