@@ -364,7 +364,10 @@ Date: April 2019
Contact: linux-pm@vger.kernel.org
Description:
Represents a battery percentage level, above which charging will
- stop.
+ stop. Not all hardware is capable of setting this to an arbitrary
+ percentage. Drivers will round written values to the nearest
+ supported value. Reading back the value will show the actual
+ threshold set by the driver.
Access: Read, Write
@@ -380,13 +383,17 @@ Description:
algorithm to adjust the charge rate dynamically, without
any user configuration required. "Custom" means that the charger
uses the charge_control_* properties as configuration for some
- different algorithm.
+ different algorithm. "Long Life" means the charger reduces its
+ charging rate in order to prolong the battery health. "Bypass"
+ means the charger bypasses the charging path around the
+ integrated converter allowing for a "smart" wall adaptor to
+ perform the power conversion externally.
Access: Read, Write
Valid values:
"Unknown", "N/A", "Trickle", "Fast", "Standard",
- "Adaptive", "Custom"
+ "Adaptive", "Custom", "Long Life", "Bypass"
What: /sys/class/power_supply/<supply_name>/charge_term_current
Date: July 2014
@@ -468,6 +475,7 @@ Description:
auto: Charge normally, respect thresholds
inhibit-charge: Do not charge while AC is attached
force-discharge: Force discharge while AC is attached
+ ================ ====================================
What: /sys/class/power_supply/<supply_name>/technology
Date: May 2007