@@ -370,3 +370,84 @@ Description:
'unknown' means software cannot determine the state, or
the reported state is invalid.
+
+What: /sys/class/regulator/.../under_voltage
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ under_voltage. This indicates if the device reports an
+ under-voltage fault (1) or not (0).
+
+What: /sys/class/regulator/.../over_current
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ over_current. This indicates if the device reports an
+ over-current fault (1) or not (0).
+
+What: /sys/class/regulator/.../regulation_out
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ regulation_out. This indicates if the device reports an
+ out-of-regulation fault (1) or not (0).
+
+What: /sys/class/regulator/.../fail
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ fail. This indicates if the device reports an output failure
+ (1) or not (0).
+
+What: /sys/class/regulator/.../over_temp
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ over_temp. This indicates if the device reports an
+ over-temperature fault (1) or not (0).
+
+What: /sys/class/regulator/.../under_voltage_warn
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ under_voltage_warn. This indicates if the device reports an
+ under-voltage warning (1) or not (0).
+
+What: /sys/class/regulator/.../over_current_warn
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ over_current_warn. This indicates if the device reports an
+ over-current warning (1) or not (0).
+
+What: /sys/class/regulator/.../over_voltage_warn
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ over_voltage_warn. This indicates if the device reports an
+ over-voltage warning (1) or not (0).
+
+What: /sys/class/regulator/.../over_temp_warn
+Date: April 2022
+KernelVersion: 5.18
+Contact: Zev Weiss <zev@bewilderbeest.net>
+Description:
+ Some regulator directories will contain a field called
+ over_temp_warn. This indicates if the device reports an
+ over-temperature warning (1) or not (0).