+ Intel Stratix10 Remote System Update (RSU) device attributes
+
+What: /sys/devices/platform/stratix10-rsu.0/current_image
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (RO) the address in flash of currently running image.
+
+What: /sys/devices/platform/stratix10-rsu.0/fail_image
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (RO) the address in flash of failed image.
+
+What: /sys/devices/platform/stratix10-rsu.0/state
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (RO) the state of RSU system.
+ The state field has two parts: major error code in
+ upper 16 bits and minor error code in lower 16 bits.
+
+ b[15:0]
+ Currently used only when major error is 0xF006
+ (CPU watchdog timeout), in which case the minor
+ error code is the value reported by CPU to
+ firmware through the RSU notify command before
+ the watchdog timeout occurs.
+
+ b[31:16]
+ 0xF001 bitstream error
+ 0xF002 hardware access failure
+ 0xF003 bitstream corruption
+ 0xF004 internal error
+ 0xF005 device error
+ 0xF006 CPU watchdog timeout
+ 0xF007 internal unknown error
+
+What: /sys/devices/platform/stratix10-rsu.0/version
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (RO) the version number of RSU firmware. 19.3 or late
+ version includes information about the firmware which
+ reported the error.
+
+ pre 19.3:
+ b[31:0]
+ 0x0 version number
+
+ 19.3 or late:
+ b[15:0]
+ 0x1 version number
+ b[31:16]
+ 0x0 no error
+ 0x0DCF Decision CMF error
+ 0x0ACF Application CMF error
+
+What: /sys/devices/platform/stratix10-rsu.0/error_location
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (RO) the error offset inside the image that failed.
+
+What: /sys/devices/platform/stratix10-rsu.0/error_details
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (RO) error code.
+
+What: /sys/devices/platform/stratix10-rsu.0/retry_counter
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (RO) the current image's retry counter, which is used by
+ user to know how many times the images is still allowed
+ to reload itself before giving up and starting RSU
+ fail-over flow.
+
+What: /sys/devices/platform/stratix10-rsu.0/reboot_image
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (WO) the address in flash of image to be loaded on next
+ reboot command.
+
+What: /sys/devices/platform/stratix10-rsu.0/notify
+Date: August 2019
+KernelVersion: 5.4
+Contact: Richard Gong <richard.gong@linux.intel.com>
+Description:
+ (WO) client to notify firmware with different actions.
+
+ b[15:0]
+ inform firmware the current software execution
+ stage.
+ 0 the first stage bootloader didn't run or
+ didn't reach the point of launching second
+ stage bootloader.
+ 1 failed in second bootloader or didn't get
+ to the point of launching the operating
+ system.
+ 2 both first and second stage bootloader ran
+ and the operating system launch was
+ attempted.
+
+ b[16]
+ 1 firmware to reset current image retry
+ counter.
+ 0 no action.
+
+ b[17]
+ 1 firmware to clear RSU log
+ 0 no action.
+
+ b[18]
+ this is negative logic
+ 1 no action
+ 0 firmware record the notify code defined
+ in b[15:0].