@@ -109,6 +109,15 @@ fan speed) is applied. PWM values range from 0 (off) to 255 (full speed).
Fan speed may be set to maximum when the temperature sensor associated with
the PWM control exceeds temp#_max.
+At Tmin - hysteresis the PWM output can either be off (0% duty cycle) or at the
+minimum (i.e. auto_point1_pwm). This behaviour can be configured using the
+pwm[1-*]_stall_disable sysfs attribute. A value of 0 means the fans will shut
+off. A value of 1 means the fans will run at auto_point1_pwm.
+
+The responsiveness of the ADT747x to temperature changes can be configured.
+This allows smoothing of the fan speed transition. To set the transition time
+set the value in ms in the temp[1-*]_smoothing sysfs attribute.
+
Notes
-----