diff --git a/Documentation/thermal/exynos_thermal_emulation b/Documentation/thermal/exynos_thermal_emulation
deleted file mode 100644
index b15efec6ca28..000000000000
--- a/Documentation/thermal/exynos_thermal_emulation
+++ /dev/null
@@ -1,53 +0,0 @@
-EXYNOS EMULATION MODE
-========================
-
-Copyright (C) 2012 Samsung Electronics
-
-Written by Jonghwa Lee <jonghwa3.lee@samsung.com>
-
-Description
------------
-
-Exynos 4x12 (4212, 4412) and 5 series provide emulation mode for thermal management unit.
-Thermal emulation mode supports software debug for TMU's operation. User can set temperature
-manually with software code and TMU will read current temperature from user value not from
-sensor's value.
-
-Enabling CONFIG_THERMAL_EMULATION option will make this support available.
-When it's enabled, sysfs node will be created as
-/sys/devices/virtual/thermal/thermal_zone'zone id'/emul_temp.
-
-The sysfs node, 'emul_node', will contain value 0 for the initial state. When you input any
-temperature you want to update to sysfs node, it automatically enable emulation mode and
-current temperature will be changed into it.
-(Exynos also supports user changeable delay time which would be used to delay of
- changing temperature. However, this node only uses same delay of real sensing time, 938us.)
-
-Exynos emulation mode requires synchronous of value changing and enabling. It means when you
-want to update the any value of delay or next temperature, then you have to enable emulation
-mode at the same time. (Or you have to keep the mode enabling.) If you don't, it fails to
-change the value to updated one and just use last succeessful value repeatedly. That's why
-this node gives users the right to change termerpature only. Just one interface makes it more
-simply to use.
-
-Disabling emulation mode only requires writing value 0 to sysfs node.
-
-
-TEMP 120 |
- |
- 100 |
- |
- 80 |
- | +-----------
- 60 | | |
- | +-------------| |
- 40 | | | |
- | | | |
- 20 | | | +----------
- | | | | |
- 0 |______________|_____________|__________|__________|_________
- A A A A TIME
- |<----->| |<----->| |<----->| |
- | 938us | | | | | |
-emulation : 0 50 | 70 | 20 | 0
-current temp : sensor 50 70 20 sensor