aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/cpufreq/arm_big_little.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/cpufreq/arm_big_little.c')
-rw-r--r--drivers/cpufreq/arm_big_little.c39
1 files changed, 13 insertions, 26 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c
index 17504129fd77..c56b57dcfda5 100644
--- a/drivers/cpufreq/arm_big_little.c
+++ b/drivers/cpufreq/arm_big_little.c
@@ -57,7 +57,7 @@ static bool bL_switching_enabled;
#define VIRT_FREQ(cluster, freq) ((cluster == A7_CLUSTER) ? freq >> 1 : freq)
static struct thermal_cooling_device *cdev[MAX_CLUSTERS];
-static struct cpufreq_arm_bL_ops *arm_bL_ops;
+static const struct cpufreq_arm_bL_ops *arm_bL_ops;
static struct clk *clk[MAX_CLUSTERS];
static struct cpufreq_frequency_table *freq_table[MAX_CLUSTERS + 1];
static atomic_t cluster_usage[MAX_CLUSTERS + 1];
@@ -213,6 +213,7 @@ static int bL_cpufreq_set_target(struct cpufreq_policy *policy,
{
u32 cpu = policy->cpu, cur_cluster, new_cluster, actual_cluster;
unsigned int freqs_new;
+ int ret;
cur_cluster = cpu_to_cluster(cpu);
new_cluster = actual_cluster = per_cpu(physical_cluster, cpu);
@@ -229,7 +230,14 @@ static int bL_cpufreq_set_target(struct cpufreq_policy *policy,
}
}
- return bL_cpufreq_set_rate(cpu, actual_cluster, new_cluster, freqs_new);
+ ret = bL_cpufreq_set_rate(cpu, actual_cluster, new_cluster, freqs_new);
+
+ if (!ret) {
+ arch_set_freq_scale(policy->related_cpus, freqs_new,
+ policy->cpuinfo.max_freq);
+ }
+
+ return ret;
}
static inline u32 get_table_count(struct cpufreq_frequency_table *table)
@@ -518,34 +526,13 @@ static int bL_cpufreq_exit(struct cpufreq_policy *policy)
static void bL_cpufreq_ready(struct cpufreq_policy *policy)
{
- struct device *cpu_dev = get_cpu_device(policy->cpu);
int cur_cluster = cpu_to_cluster(policy->cpu);
- struct device_node *np;
/* Do not register a cpu_cooling device if we are in IKS mode */
if (cur_cluster >= MAX_CLUSTERS)
return;
- np = of_node_get(cpu_dev->of_node);
- if (WARN_ON(!np))
- return;
-
- if (of_find_property(np, "#cooling-cells", NULL)) {
- u32 power_coefficient = 0;
-
- of_property_read_u32(np, "dynamic-power-coefficient",
- &power_coefficient);
-
- cdev[cur_cluster] = of_cpufreq_power_cooling_register(np,
- policy, power_coefficient, NULL);
- if (IS_ERR(cdev[cur_cluster])) {
- dev_err(cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(cdev[cur_cluster]));
- cdev[cur_cluster] = NULL;
- }
- }
- of_node_put(np);
+ cdev[cur_cluster] = of_cpufreq_cooling_register(policy);
}
static struct cpufreq_driver bL_cpufreq_driver = {
@@ -609,7 +596,7 @@ static int __bLs_register_notifier(void) { return 0; }
static int __bLs_unregister_notifier(void) { return 0; }
#endif
-int bL_cpufreq_register(struct cpufreq_arm_bL_ops *ops)
+int bL_cpufreq_register(const struct cpufreq_arm_bL_ops *ops)
{
int ret, i;
@@ -653,7 +640,7 @@ int bL_cpufreq_register(struct cpufreq_arm_bL_ops *ops)
}
EXPORT_SYMBOL_GPL(bL_cpufreq_register);
-void bL_cpufreq_unregister(struct cpufreq_arm_bL_ops *ops)
+void bL_cpufreq_unregister(const struct cpufreq_arm_bL_ops *ops)
{
if (arm_bL_ops != ops) {
pr_err("%s: Registered with: %s, can't unregister, exiting\n",