aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/media/cec-edid.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/media/cec-edid.c')
-rw-r--r--drivers/media/cec-edid.c171
1 files changed, 0 insertions, 171 deletions
diff --git a/drivers/media/cec-edid.c b/drivers/media/cec-edid.c
deleted file mode 100644
index 5719b991e340..000000000000
--- a/drivers/media/cec-edid.c
+++ /dev/null
@@ -1,171 +0,0 @@
-/*
- * cec-edid - HDMI Consumer Electronics Control EDID & CEC helper functions
- *
- * Copyright 2016 Cisco Systems, Inc. and/or its affiliates. All rights reserved.
- *
- * This program is free software; you may redistribute it and/or modify
- * it under the terms of the GNU General Public License as published by
- * the Free Software Foundation; version 2 of the License.
- *
- * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
- * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
- * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
- * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS
- * BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN
- * ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN
- * CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
- * SOFTWARE.
- */
-
-#include <linux/module.h>
-#include <linux/kernel.h>
-#include <linux/types.h>
-#include <media/cec-edid.h>
-
-/*
- * This EDID is expected to be a CEA-861 compliant, which means that there are
- * at least two blocks and one or more of the extensions blocks are CEA-861
- * blocks.
- *
- * The returned location is guaranteed to be < size - 1.
- */
-static unsigned int cec_get_edid_spa_location(const u8 *edid, unsigned int size)
-{
- unsigned int blocks = size / 128;
- unsigned int block;
- u8 d;
-
- /* Sanity check: at least 2 blocks and a multiple of the block size */
- if (blocks < 2 || size % 128)
- return 0;
-
- /*
- * If there are fewer extension blocks than the size, then update
- * 'blocks'. It is allowed to have more extension blocks than the size,
- * since some hardware can only read e.g. 256 bytes of the EDID, even
- * though more blocks are present. The first CEA-861 extension block
- * should normally be in block 1 anyway.
- */
- if (edid[0x7e] + 1 < blocks)
- blocks = edid[0x7e] + 1;
-
- for (block = 1; block < blocks; block++) {
- unsigned int offset = block * 128;
-
- /* Skip any non-CEA-861 extension blocks */
- if (edid[offset] != 0x02 || edid[offset + 1] != 0x03)
- continue;
-
- /* search Vendor Specific Data Block (tag 3) */
- d = edid[offset + 2] & 0x7f;
- /* Check if there are Data Blocks */
- if (d <= 4)
- continue;
- if (d > 4) {
- unsigned int i = offset + 4;
- unsigned int end = offset + d;
-
- /* Note: 'end' is always < 'size' */
- do {
- u8 tag = edid[i] >> 5;
- u8 len = edid[i] & 0x1f;
-
- if (tag == 3 && len >= 5 && i + len <= end &&
- edid[i + 1] == 0x03 &&
- edid[i + 2] == 0x0c &&
- edid[i + 3] == 0x00)
- return i + 4;
- i += len + 1;
- } while (i < end);
- }
- }
- return 0;
-}
-
-u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
- unsigned int *offset)
-{
- unsigned int loc = cec_get_edid_spa_location(edid, size);
-
- if (offset)
- *offset = loc;
- if (loc == 0)
- return CEC_PHYS_ADDR_INVALID;
- return (edid[loc] << 8) | edid[loc + 1];
-}
-EXPORT_SYMBOL_GPL(cec_get_edid_phys_addr);
-
-void cec_set_edid_phys_addr(u8 *edid, unsigned int size, u16 phys_addr)
-{
- unsigned int loc = cec_get_edid_spa_location(edid, size);
- u8 sum = 0;
- unsigned int i;
-
- if (loc == 0)
- return;
- edid[loc] = phys_addr >> 8;
- edid[loc + 1] = phys_addr & 0xff;
- loc &= ~0x7f;
-
- /* update the checksum */
- for (i = loc; i < loc + 127; i++)
- sum += edid[i];
- edid[i] = 256 - sum;
-}
-EXPORT_SYMBOL_GPL(cec_set_edid_phys_addr);
-
-u16 cec_phys_addr_for_input(u16 phys_addr, u8 input)
-{
- /* Check if input is sane */
- if (WARN_ON(input == 0 || input > 0xf))
- return CEC_PHYS_ADDR_INVALID;
-
- if (phys_addr == 0)
- return input << 12;
-
- if ((phys_addr & 0x0fff) == 0)
- return phys_addr | (input << 8);
-
- if ((phys_addr & 0x00ff) == 0)
- return phys_addr | (input << 4);
-
- if ((phys_addr & 0x000f) == 0)
- return phys_addr | input;
-
- /*
- * All nibbles are used so no valid physical addresses can be assigned
- * to the input.
- */
- return CEC_PHYS_ADDR_INVALID;
-}
-EXPORT_SYMBOL_GPL(cec_phys_addr_for_input);
-
-int cec_phys_addr_validate(u16 phys_addr, u16 *parent, u16 *port)
-{
- int i;
-
- if (parent)
- *parent = phys_addr;
- if (port)
- *port = 0;
- if (phys_addr == CEC_PHYS_ADDR_INVALID)
- return 0;
- for (i = 0; i < 16; i += 4)
- if (phys_addr & (0xf << i))
- break;
- if (i == 16)
- return 0;
- if (parent)
- *parent = phys_addr & (0xfff0 << i);
- if (port)
- *port = (phys_addr >> i) & 0xf;
- for (i += 4; i < 16; i += 4)
- if ((phys_addr & (0xf << i)) == 0)
- return -EINVAL;
- return 0;
-}
-EXPORT_SYMBOL_GPL(cec_phys_addr_validate);
-
-MODULE_AUTHOR("Hans Verkuil <hans.verkuil@cisco.com>");
-MODULE_DESCRIPTION("CEC EDID helper functions");
-MODULE_LICENSE("GPL");