aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/intel/e1000e/phy.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/ethernet/intel/e1000e/phy.c')
-rw-r--r--drivers/net/ethernet/intel/e1000e/phy.c141
1 files changed, 47 insertions, 94 deletions
diff --git a/drivers/net/ethernet/intel/e1000e/phy.c b/drivers/net/ethernet/intel/e1000e/phy.c
index fc62a3f3a5be..28b38ff37e84 100644
--- a/drivers/net/ethernet/intel/e1000e/phy.c
+++ b/drivers/net/ethernet/intel/e1000e/phy.c
@@ -193,8 +193,7 @@ s32 e1000e_read_phy_reg_mdic(struct e1000_hw *hw, u32 offset, u16 *data)
return -E1000_ERR_PARAM;
}
- /*
- * Set up Op-code, Phy Address, and register offset in the MDI
+ /* Set up Op-code, Phy Address, and register offset in the MDI
* Control register. The MAC will take care of interfacing with the
* PHY to retrieve the desired data.
*/
@@ -204,8 +203,7 @@ s32 e1000e_read_phy_reg_mdic(struct e1000_hw *hw, u32 offset, u16 *data)
ew32(MDIC, mdic);
- /*
- * Poll the ready bit to see if the MDI read completed
+ /* Poll the ready bit to see if the MDI read completed
* Increasing the time out as testing showed failures with
* the lower time out
*/
@@ -225,8 +223,7 @@ s32 e1000e_read_phy_reg_mdic(struct e1000_hw *hw, u32 offset, u16 *data)
}
*data = (u16) mdic;
- /*
- * Allow some time after each MDIC transaction to avoid
+ /* Allow some time after each MDIC transaction to avoid
* reading duplicate data in the next MDIC transaction.
*/
if (hw->mac.type == e1000_pch2lan)
@@ -253,8 +250,7 @@ s32 e1000e_write_phy_reg_mdic(struct e1000_hw *hw, u32 offset, u16 data)
return -E1000_ERR_PARAM;
}
- /*
- * Set up Op-code, Phy Address, and register offset in the MDI
+ /* Set up Op-code, Phy Address, and register offset in the MDI
* Control register. The MAC will take care of interfacing with the
* PHY to retrieve the desired data.
*/
@@ -265,8 +261,7 @@ s32 e1000e_write_phy_reg_mdic(struct e1000_hw *hw, u32 offset, u16 data)
ew32(MDIC, mdic);
- /*
- * Poll the ready bit to see if the MDI read completed
+ /* Poll the ready bit to see if the MDI read completed
* Increasing the time out as testing showed failures with
* the lower time out
*/
@@ -285,8 +280,7 @@ s32 e1000e_write_phy_reg_mdic(struct e1000_hw *hw, u32 offset, u16 data)
return -E1000_ERR_PHY;
}
- /*
- * Allow some time after each MDIC transaction to avoid
+ /* Allow some time after each MDIC transaction to avoid
* reading duplicate data in the next MDIC transaction.
*/
if (hw->mac.type == e1000_pch2lan)
@@ -708,8 +702,7 @@ s32 e1000_copper_link_setup_82577(struct e1000_hw *hw)
if (ret_val)
return ret_val;
phy_data &= ~I82577_PHY_CTRL2_MDIX_CFG_MASK;
- /*
- * Options:
+ /* Options:
* 0 - Auto (default)
* 1 - MDI mode
* 2 - MDI-X mode
@@ -754,8 +747,7 @@ s32 e1000e_copper_link_setup_m88(struct e1000_hw *hw)
if (phy->type != e1000_phy_bm)
phy_data |= M88E1000_PSCR_ASSERT_CRS_ON_TX;
- /*
- * Options:
+ /* Options:
* MDI/MDI-X = 0 (default)
* 0 - Auto for all speeds
* 1 - MDI mode
@@ -780,8 +772,7 @@ s32 e1000e_copper_link_setup_m88(struct e1000_hw *hw)
break;
}
- /*
- * Options:
+ /* Options:
* disable_polarity_correction = 0 (default)
* Automatic Correction for Reversed Cable Polarity
* 0 - Disabled
@@ -818,8 +809,7 @@ s32 e1000e_copper_link_setup_m88(struct e1000_hw *hw)
if ((phy->type == e1000_phy_m88) &&
(phy->revision < E1000_REVISION_4) &&
(phy->id != BME1000_E_PHY_ID_R2)) {
- /*
- * Force TX_CLK in the Extended PHY Specific Control Register
+ /* Force TX_CLK in the Extended PHY Specific Control Register
* to 25MHz clock.
*/
ret_val = e1e_rphy(hw, M88E1000_EXT_PHY_SPEC_CTRL, &phy_data);
@@ -899,8 +889,7 @@ s32 e1000e_copper_link_setup_igp(struct e1000_hw *hw)
return ret_val;
}
- /*
- * Wait 100ms for MAC to configure PHY from NVM settings, to avoid
+ /* Wait 100ms for MAC to configure PHY from NVM settings, to avoid
* timeout issues when LFS is enabled.
*/
msleep(100);
@@ -936,8 +925,7 @@ s32 e1000e_copper_link_setup_igp(struct e1000_hw *hw)
/* set auto-master slave resolution settings */
if (hw->mac.autoneg) {
- /*
- * when autonegotiation advertisement is only 1000Mbps then we
+ /* when autonegotiation advertisement is only 1000Mbps then we
* should disable SmartSpeed and enable Auto MasterSlave
* resolution as hardware default.
*/
@@ -1001,16 +989,14 @@ static s32 e1000_phy_setup_autoneg(struct e1000_hw *hw)
return ret_val;
}
- /*
- * Need to parse both autoneg_advertised and fc and set up
+ /* Need to parse both autoneg_advertised and fc and set up
* the appropriate PHY registers. First we will parse for
* autoneg_advertised software override. Since we can advertise
* a plethora of combinations, we need to check each bit
* individually.
*/
- /*
- * First we clear all the 10/100 mb speed bits in the Auto-Neg
+ /* First we clear all the 10/100 mb speed bits in the Auto-Neg
* Advertisement Register (Address 4) and the 1000 mb speed bits in
* the 1000Base-T Control Register (Address 9).
*/
@@ -1056,8 +1042,7 @@ static s32 e1000_phy_setup_autoneg(struct e1000_hw *hw)
mii_1000t_ctrl_reg |= CR_1000T_FD_CAPS;
}
- /*
- * Check for a software override of the flow control settings, and
+ /* Check for a software override of the flow control settings, and
* setup the PHY advertisement registers accordingly. If
* auto-negotiation is enabled, then software will have to set the
* "PAUSE" bits to the correct value in the Auto-Negotiation
@@ -1076,15 +1061,13 @@ static s32 e1000_phy_setup_autoneg(struct e1000_hw *hw)
*/
switch (hw->fc.current_mode) {
case e1000_fc_none:
- /*
- * Flow control (Rx & Tx) is completely disabled by a
+ /* Flow control (Rx & Tx) is completely disabled by a
* software over-ride.
*/
mii_autoneg_adv_reg &= ~(NWAY_AR_ASM_DIR | NWAY_AR_PAUSE);
break;
case e1000_fc_rx_pause:
- /*
- * Rx Flow control is enabled, and Tx Flow control is
+ /* Rx Flow control is enabled, and Tx Flow control is
* disabled, by a software over-ride.
*
* Since there really isn't a way to advertise that we are
@@ -1096,16 +1079,14 @@ static s32 e1000_phy_setup_autoneg(struct e1000_hw *hw)
mii_autoneg_adv_reg |= (NWAY_AR_ASM_DIR | NWAY_AR_PAUSE);
break;
case e1000_fc_tx_pause:
- /*
- * Tx Flow control is enabled, and Rx Flow control is
+ /* Tx Flow control is enabled, and Rx Flow control is
* disabled, by a software over-ride.
*/
mii_autoneg_adv_reg |= NWAY_AR_ASM_DIR;
mii_autoneg_adv_reg &= ~NWAY_AR_PAUSE;
break;
case e1000_fc_full:
- /*
- * Flow control (both Rx and Tx) is enabled by a software
+ /* Flow control (both Rx and Tx) is enabled by a software
* over-ride.
*/
mii_autoneg_adv_reg |= (NWAY_AR_ASM_DIR | NWAY_AR_PAUSE);
@@ -1142,14 +1123,12 @@ static s32 e1000_copper_link_autoneg(struct e1000_hw *hw)
s32 ret_val;
u16 phy_ctrl;
- /*
- * Perform some bounds checking on the autoneg advertisement
+ /* Perform some bounds checking on the autoneg advertisement
* parameter.
*/
phy->autoneg_advertised &= phy->autoneg_mask;
- /*
- * If autoneg_advertised is zero, we assume it was not defaulted
+ /* If autoneg_advertised is zero, we assume it was not defaulted
* by the calling code so we set to advertise full capability.
*/
if (!phy->autoneg_advertised)
@@ -1163,8 +1142,7 @@ static s32 e1000_copper_link_autoneg(struct e1000_hw *hw)
}
e_dbg("Restarting Auto-Neg\n");
- /*
- * Restart auto-negotiation by setting the Auto Neg Enable bit and
+ /* Restart auto-negotiation by setting the Auto Neg Enable bit and
* the Auto Neg Restart bit in the PHY control register.
*/
ret_val = e1e_rphy(hw, PHY_CONTROL, &phy_ctrl);
@@ -1176,8 +1154,7 @@ static s32 e1000_copper_link_autoneg(struct e1000_hw *hw)
if (ret_val)
return ret_val;
- /*
- * Does the user want to wait for Auto-Neg to complete here, or
+ /* Does the user want to wait for Auto-Neg to complete here, or
* check at a later time (for example, callback routine).
*/
if (phy->autoneg_wait_to_complete) {
@@ -1208,16 +1185,14 @@ s32 e1000e_setup_copper_link(struct e1000_hw *hw)
bool link;
if (hw->mac.autoneg) {
- /*
- * Setup autoneg and flow control advertisement and perform
+ /* Setup autoneg and flow control advertisement and perform
* autonegotiation.
*/
ret_val = e1000_copper_link_autoneg(hw);
if (ret_val)
return ret_val;
} else {
- /*
- * PHY will be set to 10H, 10F, 100H or 100F
+ /* PHY will be set to 10H, 10F, 100H or 100F
* depending on user settings.
*/
e_dbg("Forcing Speed and Duplex\n");
@@ -1228,8 +1203,7 @@ s32 e1000e_setup_copper_link(struct e1000_hw *hw)
}
}
- /*
- * Check link status. Wait up to 100 microseconds for link to become
+ /* Check link status. Wait up to 100 microseconds for link to become
* valid.
*/
ret_val = e1000e_phy_has_link_generic(hw, COPPER_LINK_UP_LIMIT, 10,
@@ -1273,8 +1247,7 @@ s32 e1000e_phy_force_speed_duplex_igp(struct e1000_hw *hw)
if (ret_val)
return ret_val;
- /*
- * Clear Auto-Crossover to force MDI manually. IGP requires MDI
+ /* Clear Auto-Crossover to force MDI manually. IGP requires MDI
* forced whenever speed and duplex are forced.
*/
ret_val = e1e_rphy(hw, IGP01E1000_PHY_PORT_CTRL, &phy_data);
@@ -1328,8 +1301,7 @@ s32 e1000e_phy_force_speed_duplex_m88(struct e1000_hw *hw)
u16 phy_data;
bool link;
- /*
- * Clear Auto-Crossover to force MDI manually. M88E1000 requires MDI
+ /* Clear Auto-Crossover to force MDI manually. M88E1000 requires MDI
* forced whenever speed and duplex are forced.
*/
ret_val = e1e_rphy(hw, M88E1000_PHY_SPEC_CTRL, &phy_data);
@@ -1370,8 +1342,7 @@ s32 e1000e_phy_force_speed_duplex_m88(struct e1000_hw *hw)
if (hw->phy.type != e1000_phy_m88) {
e_dbg("Link taking longer than expected.\n");
} else {
- /*
- * We didn't get link.
+ /* We didn't get link.
* Reset the DSP and cross our fingers.
*/
ret_val = e1e_wphy(hw, M88E1000_PHY_PAGE_SELECT,
@@ -1398,8 +1369,7 @@ s32 e1000e_phy_force_speed_duplex_m88(struct e1000_hw *hw)
if (ret_val)
return ret_val;
- /*
- * Resetting the phy means we need to re-force TX_CLK in the
+ /* Resetting the phy means we need to re-force TX_CLK in the
* Extended PHY Specific Control Register to 25MHz clock from
* the reset value of 2.5MHz.
*/
@@ -1408,8 +1378,7 @@ s32 e1000e_phy_force_speed_duplex_m88(struct e1000_hw *hw)
if (ret_val)
return ret_val;
- /*
- * In addition, we must re-enable CRS on Tx for both half and full
+ /* In addition, we must re-enable CRS on Tx for both half and full
* duplex.
*/
ret_val = e1e_rphy(hw, M88E1000_PHY_SPEC_CTRL, &phy_data);
@@ -1573,8 +1542,7 @@ s32 e1000e_set_d3_lplu_state(struct e1000_hw *hw, bool active)
ret_val = e1e_wphy(hw, IGP02E1000_PHY_POWER_MGMT, data);
if (ret_val)
return ret_val;
- /*
- * LPLU and SmartSpeed are mutually exclusive. LPLU is used
+ /* LPLU and SmartSpeed are mutually exclusive. LPLU is used
* during Dx states where the power conservation is most
* important. During driver activity we should enable
* SmartSpeed, so performance is maintained.
@@ -1702,8 +1670,7 @@ s32 e1000_check_polarity_igp(struct e1000_hw *hw)
s32 ret_val;
u16 data, offset, mask;
- /*
- * Polarity is determined based on the speed of
+ /* Polarity is determined based on the speed of
* our connection.
*/
ret_val = e1e_rphy(hw, IGP01E1000_PHY_PORT_STATUS, &data);
@@ -1715,8 +1682,7 @@ s32 e1000_check_polarity_igp(struct e1000_hw *hw)
offset = IGP01E1000_PHY_PCS_INIT_REG;
mask = IGP01E1000_PHY_POLARITY_MASK;
} else {
- /*
- * This really only applies to 10Mbps since
+ /* This really only applies to 10Mbps since
* there is no polarity for 100Mbps (always 0).
*/
offset = IGP01E1000_PHY_PORT_STATUS;
@@ -1745,8 +1711,7 @@ s32 e1000_check_polarity_ife(struct e1000_hw *hw)
s32 ret_val;
u16 phy_data, offset, mask;
- /*
- * Polarity is determined based on the reversal feature being enabled.
+ /* Polarity is determined based on the reversal feature being enabled.
*/
if (phy->polarity_correction) {
offset = IFE_PHY_EXTENDED_STATUS_CONTROL;
@@ -1791,8 +1756,7 @@ static s32 e1000_wait_autoneg(struct e1000_hw *hw)
msleep(100);
}
- /*
- * PHY_AUTO_NEG_TIME expiration doesn't guarantee auto-negotiation
+ /* PHY_AUTO_NEG_TIME expiration doesn't guarantee auto-negotiation
* has completed.
*/
return ret_val;
@@ -1814,15 +1778,13 @@ s32 e1000e_phy_has_link_generic(struct e1000_hw *hw, u32 iterations,
u16 i, phy_status;
for (i = 0; i < iterations; i++) {
- /*
- * Some PHYs require the PHY_STATUS register to be read
+ /* Some PHYs require the PHY_STATUS register to be read
* twice due to the link bit being sticky. No harm doing
* it across the board.
*/
ret_val = e1e_rphy(hw, PHY_STATUS, &phy_status);
if (ret_val)
- /*
- * If the first read fails, another entity may have
+ /* If the first read fails, another entity may have
* ownership of the resources, wait and try again to
* see if they have relinquished the resources yet.
*/
@@ -1913,8 +1875,7 @@ s32 e1000e_get_cable_length_igp_2(struct e1000_hw *hw)
if (ret_val)
return ret_val;
- /*
- * Getting bits 15:9, which represent the combination of
+ /* Getting bits 15:9, which represent the combination of
* coarse and fine gain values. The result is a number
* that can be put into the lookup table to obtain the
* approximate cable length.
@@ -2285,15 +2246,13 @@ s32 e1000e_phy_init_script_igp3(struct e1000_hw *hw)
e1e_wphy(hw, 0x1796, 0x0008);
/* Change cg_icount + enable integbp for channels BCD */
e1e_wphy(hw, 0x1798, 0xD008);
- /*
- * Change cg_icount + enable integbp + change prop_factor_master
+ /* Change cg_icount + enable integbp + change prop_factor_master
* to 8 for channel A
*/
e1e_wphy(hw, 0x1898, 0xD918);
/* Disable AHT in Slave mode on channel A */
e1e_wphy(hw, 0x187A, 0x0800);
- /*
- * Enable LPLU and disable AN to 1000 in non-D0a states,
+ /* Enable LPLU and disable AN to 1000 in non-D0a states,
* Enable SPD+B2B
*/
e1e_wphy(hw, 0x0019, 0x008D);
@@ -2417,8 +2376,7 @@ s32 e1000e_determine_phy_address(struct e1000_hw *hw)
e1000e_get_phy_id(hw);
phy_type = e1000e_get_phy_type_from_id(hw->phy.id);
- /*
- * If phy_type is valid, break - we found our
+ /* If phy_type is valid, break - we found our
* PHY address
*/
if (phy_type != e1000_phy_unknown)
@@ -2478,8 +2436,7 @@ s32 e1000e_write_phy_reg_bm(struct e1000_hw *hw, u32 offset, u16 data)
if (offset > MAX_PHY_MULTI_PAGE_REG) {
u32 page_shift, page_select;
- /*
- * Page select is register 31 for phy address 1 and 22 for
+ /* Page select is register 31 for phy address 1 and 22 for
* phy address 2 and 3. Page select is shifted only for
* phy address 1.
*/
@@ -2537,8 +2494,7 @@ s32 e1000e_read_phy_reg_bm(struct e1000_hw *hw, u32 offset, u16 *data)
if (offset > MAX_PHY_MULTI_PAGE_REG) {
u32 page_shift, page_select;
- /*
- * Page select is register 31 for phy address 1 and 22 for
+ /* Page select is register 31 for phy address 1 and 22 for
* phy address 2 and 3. Page select is shifted only for
* phy address 1.
*/
@@ -2683,8 +2639,7 @@ s32 e1000_enable_phy_wakeup_reg_access_bm(struct e1000_hw *hw, u16 *phy_reg)
return ret_val;
}
- /*
- * Enable both PHY wakeup mode and Wakeup register page writes.
+ /* Enable both PHY wakeup mode and Wakeup register page writes.
* Prevent a power state change by disabling ME and Host PHY wakeup.
*/
temp = *phy_reg;
@@ -2698,8 +2653,7 @@ s32 e1000_enable_phy_wakeup_reg_access_bm(struct e1000_hw *hw, u16 *phy_reg)
return ret_val;
}
- /*
- * Select Host Wakeup Registers page - caller now able to write
+ /* Select Host Wakeup Registers page - caller now able to write
* registers on the Wakeup registers page
*/
return e1000_set_page_igp(hw, (BM_WUC_PAGE << IGP_PAGE_SHIFT));
@@ -3038,8 +2992,7 @@ static s32 __e1000_write_phy_reg_hv(struct e1000_hw *hw, u32 offset, u16 data,
if (page == HV_INTC_FC_PAGE_START)
page = 0;
- /*
- * Workaround MDIO accesses being disabled after entering IEEE
+ /* Workaround MDIO accesses being disabled after entering IEEE
* Power Down (when bit 11 of the PHY Control register is set)
*/
if ((hw->phy.type == e1000_phy_82578) &&