diff --git a/tools/perf/Documentation/perf-top.txt b/tools/perf/Documentation/perf-top.txt
index 324b6b53c86b..c1fdba26bf53 100644
--- a/tools/perf/Documentation/perf-top.txt
+++ b/tools/perf/Documentation/perf-top.txt
@@ -38,9 +38,10 @@ Default is to monitor all CPUS.
-e <event>::
--event=<event>::
Select the PMU event. Selection can be a symbolic event name
- (use 'perf list' to list all events) or a raw PMU
- event (eventsel+umask) in the form of rNNN where NNN is a
- hexadecimal event descriptor.
+ (use 'perf list' to list all events) or a raw PMU event in the form
+ of rN where N is a hexadecimal value that represents the raw register
+ encoding with the layout of the event control registers as described
+ by entries in /sys/bus/event_source/devices/cpu/format/*.
-E <entries>::
--entries=<entries>::
@@ -53,6 +54,11 @@ Default is to monitor all CPUS.
--group::
Put the counters into a counter group.
+--group-sort-idx::
+ Sort the output by the event at the index n in group. If n is invalid,
+ sort by the first event. It can support multiple groups with different
+ amount of events. WARNING: This should be used on grouped events.
+
-F <freq>::
--freq=<freq>::
Profile at this frequency. Use 'max' to use the currently maximum
@@ -272,6 +278,22 @@ Default is to monitor all CPUS.
Record events of type PERF_RECORD_NAMESPACES and display it with the
'cgroup_id' sort key.
+-G name::
+--cgroup name::
+monitor only in the container (cgroup) called "name". This option is available only
+in per-cpu mode. The cgroup filesystem must be mounted. All threads belonging to
+container "name" are monitored when they run on the monitored CPUs. Multiple cgroups
+can be provided. Each cgroup is applied to the corresponding event, i.e., first cgroup
+to first event, second cgroup to second event and so on. It is possible to provide
+an empty cgroup (monitor all the time) using, e.g., -G foo,,bar. Cgroups must have
+corresponding events, i.e., they always refer to events defined earlier on the command
+line. If the user wants to track multiple events for a specific cgroup, the user can
+use '-e e1 -e e2 -G foo,foo' or just use '-e e1 -e e2 -G foo'.
+
+--all-cgroups::
+ Record events of type PERF_RECORD_CGROUP and display it with the
+ 'cgroup' sort key.
+
--switch-on EVENT_NAME::
Only consider events after this event is found.
@@ -308,8 +330,28 @@ Default is to monitor all CPUS.
but probably we'll make the default not to show the switch-on/off events
on the --group mode and if there is only one event besides the off/on ones,
go straight to the histogram browser, just like 'perf top' with no events
- explicitely specified does.
-
+ explicitly specified does.
+
+--stitch-lbr::
+ Show callgraph with stitched LBRs, which may have more complete
+ callgraph. The option must be used with --call-graph lbr recording.
+ Disabled by default. In common cases with call stack overflows,
+ it can recreate better call stacks than the default lbr call stack
+ output. But this approach is not full proof. There can be cases
+ where it creates incorrect call stacks from incorrect matches.
+ The known limitations include exception handing such as
+ setjmp/longjmp will have calls/returns not match.
+
+ifdef::HAVE_LIBPFM[]
+--pfm-events events::
+Select a PMU event using libpfm4 syntax (see http://perfmon2.sf.net)
+including support for event filters. For example '--pfm-events
+inst_retired:any_p:u:c=1:i'. More than one event can be passed to the
+option using the comma separator. Hardware events and generic hardware
+events cannot be mixed together. The latter must be used with the -e
+option. The -e option and this one can be mixed and matched. Events
+can be grouped using the {} notation.
+endif::HAVE_LIBPFM[]
INTERACTIVE PROMPTING KEYS
--------------------------