AgeCommit message (Collapse)AuthorFilesLines
2011-10-24hwmon: (pmbus_core) Simplify sign extensionsGuenter Roeck1-13/+4
Shift operations can be used for sign extensions. Use it. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Add support for Lineage Power DC-DC convertersGuenter Roeck1-0/+4
Add device IDs and reference to datasheets for Lineage Power DC-DC converters. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus/ltc2978) Add support for LTC3880 to LTC2978 driverGuenter Roeck2-14/+127
The LTC3880 PMBus command set is comparable to LTC2978. Add support for it to the LTC2978 driver. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus/ltc2978) Explicit driver for LTC2978Guenter Roeck4-2/+307
Provide explicit driver for LTC2978 to enable support for minimum and peak attributes. Remove ltc2978 chip id from generic pmbus driver. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Add support for TEMP2 peak attributesGuenter Roeck2-5/+43
At least one PMBus chip supports peak attributes for READ_TEMPERATURE2. Add virtual registers to be able to report it to the user. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Add support for Intersil power management chipsGuenter Roeck3-0/+268
Add support for Intersil / Zilker Labs ZL2004, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, and ZL6105. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Always call _pmbus_read_byte in core driverGuenter Roeck6-15/+17
Always call _pmbus_read_byte() instead of pmbus_read_byte() in PMBus core driver. With this change, device specific read functions can be implemented for all registers. Since the device specific read_byte function is now always called, we need to be more careful with page validations. Only fail if the passed page number is larger than 0, since -1 means "current page". Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Replace EINVAL return codes with more appropriate errorsGuenter Roeck4-13/+13
EINVAL was over-used in the code. Replace it with more appropriate errors. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus/adm1275) Add support for ADM1276Guenter Roeck2-10/+54
ADM1276 is mostly compatible to ADM1275, with added support for input power measurement. Add support for it to the ADM1275 driver. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-10-24hwmon: (pmbus/adm1275) Add support for second current limitGuenter Roeck1-7/+88
ADM1275 supports a second current limit, which can be configured as either lower or upper limit. Add support for it and report it as either lower or upper critical current limit. Also replace error return code EINVAL for unsupported pages with ENXIO as this is more appropriate for the observed condition. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-10-24hwmon: (pmbus) Don't return errors from driver remove functionsGuenter Roeck10-21/+18
Driver remove functions have an error return value, but rarely return an error in practice. If a driver does return an error from its remove function, the driver won't be unloaded and is expected to stay alive. pmbus_do_remove() is defined as returning an int, but always returns 0 (no error). Calling code passes that return value on to high level driver remove functions, but does not evaluate it and removes driver data even if pmbus_do_remove() returned an error (which it in practice never does). Even if this code could never cause a real problem, it is nevertheless conceptually wrong. To reduce confusion and simplify the code, change pmbus_do_remove() to be a void function, and have PMBus client drivers always return zero in their driver remove functions. Reported-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-10-24hwmon: (pmbus) Add comments explaining internal driver API return valuesGuenter Roeck1-2/+16
Return values for functions reading/writing manufacturer specific registers are poorly explained. Add comments to improve documentation. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-09-13hwmon: (pmbus) Fix low limit temperature alarmsGuenter Roeck1-1/+8
Temperature alarms are detected by checking the alarm bit and comparing temperature limits against the current temperature. For low limits, this comparison needs to be reversed (temp < limit instead of temp > limit). This was not taken into account, resulting in wrong alarms if a temperature fell below a low limit. Fix by adding a low limit flag in the limit data structure. When creating the sensor entry, the order of registers to compare is now reversed for low limits. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org> Cc: stable@kernel.org # 3.0+
2011-09-06hwmon: (ucd9000/ucd9200) Optimize array walkJean Delvare2-8/+4
Rewrite the loop walking the id array during probe. The new code is better adapted to a null-terminated array, and is also clearer and more efficient than the original. Signed-off-by: Jean Delvare <khali@linux-fr.org> Cc: Axel Lin <axel.lin@gmail.com> Cc: Guenter Roeck <guenter.roeck@ericsson.com> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
2011-08-11hwmon: (pmbus/lm25066) Ignore byte writes to non-zero pagesGuenter Roeck1-0/+12
pmbus_clear_faults() attempts to clear faults on non-existing real pages. As a result, the command error bit in the status register is set, and faults are not really cleared. All byte writes to non-zero pages are requests to clear the status register on that page. Since non-zero pages are virtual and do not exist on the chip, there is nothing to do, and such requests have to be ignored. This fixes above problem. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-08-11hwmon: (pmbus) Virtualize pmbus_write_byteGuenter Roeck2-1/+20
With virtual pages and to be able to handle more chips, it is necessary to virtualise pmbus_write_byte(). Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add client driver for LM25066, LM5064, and LM5066Guenter Roeck5-1/+354
PMBus client driver supporting National Semiconductor LM25066, LM5064, and LM5066. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (max34440) Add support for peak attributesGuenter Roeck1-0/+63
Add support for voltage, current, and temperature peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (max8688) Add support for peak attributesGuenter Roeck1-0/+61
Add support for voltage, current, and temperature peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
2011-07-28hwmon: (max16064) Add support for peak attributesGuenter Roeck1-0/+51
Add support for voltage and temperature peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (adm1275) Add support for peak attributesGuenter Roeck1-0/+60
Add support for voltage and current peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for peak attributesGuenter Roeck2-15/+163
Most PMBus devices provide manufacturer specific commands to read low and/or high peak values for some or all of its sensors. To support providing those values as lowest/highest attributes to the user, introduce virtual PMBus commands. Those commands reside outside the normal command set and have to be implemented in device specific code, which map the virtual commands to device specific commands. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Strengthen check for status register existenceGuenter Roeck1-21/+23
With virtual register page support, it is now possible that the status register on virtual pages does not exist or is itself virtual. To take this into account when creating alarm attributes, generate those attributes only if the status register on the respective page is known to exist. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for virtual pagesGuenter Roeck2-28/+20
Some PMBus chips have non-standard sensor registers. An easy way to support such sensors is to introduce virtual pages and map the non-standard registers into standard registers on an extra page. For this to work, the code verifying if the configured number of pages exists has to be removed. Since a wrong number of pages can only be configured in a front-end driver, this should not have a practical impact since the resulting errors should be found during development and testing. Also, functions to read the chip status while checking if a command register exists must be modified to no longer set the page register before reading the status, since the physical page associated with the checked register may not exist. This does not make a functional difference since the page was already set when the attempt to read the register was made. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Support reading and writing of word registers in device specific codeGuenter Roeck2-6/+50
Some PMBus devices use non-standard registers for some of the sensors and/or limits. To support such devices, add code to support reading and writing of word size registers in device specific code. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Increase attribute name sizeGuenter Roeck1-4/+6
Some hwmon sysfs attributes have a length of 20 bytes (plus terminating 0). I2C_NAME_SIZE is defined as 20 and thus can not be used to define the length of hwmon sysfs attributes. Replace it with PMBUS_NAME_SIZE, set to 24. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add ADP4000, NCP4200 and NCP4208 to list of supported devicesGuenter Roeck2-2/+5
Add ADP4000, NCP4200 and NCP4208 to the list of devices supported by the generic PMBus driver, and add device IDs to enable explicit instantiation. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-07-28hwmon: (pmbus) Add support for VID output voltage modeGuenter Roeck7-34/+105
In VID mode, output voltages are measured and reported as VID values, and have to be converted to voltages using VID conversion tables or functions. Support is added for VR11 only at this time. This patch enables support for PMBus devices supporting VID VR11 based output voltage selection such as NCP4200 and NCP4208. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Move PMBus drivers to drivers/hwmon/pmbusGuenter Roeck11-0/+3257
Since the number of PMBus drivers is getting large, move them into directory drivers/hwmon/pmbus to improve readability and scalability. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>