2010-03-03regulator: Add WM8994 regulator supportMark Brown3-0/+312
The WM8994 contains two LDOs with mixed hardware/software control to minimise the number of external supplies required while delivering optimal voltages to minimise power consumption. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-03-03regulator: enable max8649 regulator driverHaojian Zhuang3-0/+416
Signed-off-by: Haojian Zhuang <haojian.zhuang@marvell.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-03-03regulator: trivial: fix typos in user-visible Kconfig textAlex Chiang1-2/+2
Fix Kconfig text for some Wolfson Micro devices. Cc: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Alex Chiang <achiang@hp.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-03-03regulator: mc13783: consider Power Gates as digital regulators.Alberto Panizzo1-6/+126
GPO regulators are digital outputs that can be enabled or disabled by a dedicated bit in mc13783 POWERMISC register. In this family can be count in also Power Gates (PWGT1 and 2): enabled by a dedicated pin a Power Gate is an hardware driven supply where the output (PWGTnDRV) follow this law: Bit PWGTxSPIEN | Pin PWGTxEN | PWGTxDRV | Read Back 0 = default | | | PWGTxSPIEN ---------------+-------------+----------+------------ 1 | x | Low | 0 0 | 0 | High | 1 0 | 1 | Low | 0 As read back value of control bit reflects the PWGTxDRV state (not the control value previously written) and mc13783 POWERMISC register contain only regulator related bits, a dedicated function to manage these bits is created here with the aim of tracing the real value of PWGTxSPIEN bits and reproduce it on next writes. All POWERMISC users _must_ use the new function to not accidentally disable Power Gates supplies. v2 changes: -Better utilization of abstraction layers. -Voltage query support. GPO's and PWGTxDRV are fixed voltage regulator with voltage value of 3.1V and 5.5V respectively. Signed-off-by: Alberto Panizzo <maramaopercheseimorto@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-03-03regulator: Add 'start-up time' to fixed voltage regulatorsAdrian Hunter1-0/+5
Add a field to specify a delay for the start-up time of a fixed voltage regulator. Signed-off-by: Adrian Hunter <adrian.hunter@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-03-03regulator: Implement enable_time() for WM835x ISINKsMark Brown1-0/+46
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
2010-03-03regulator: Allow regulators to specify the time taken to ramp on enableMark Brown1-6/+35
Regulators may sometimes take longer to enable than the control operation used to do so, either because the regulator has ramp rate control used to limit inrush current or because the control operation is very fast (GPIO being the most common example of this). In order to ensure that consumers do not rely on the regulator before it is enabled provide an enable_time() operation and have the core delay for that time before returning to the caller. This is implemented as a function since the ramp rate may be specified in voltage per unit time and therefore the time depend on the configuration. In future it would be desirable to allow the bulk operations to run the delays for multiple enables in parallel but this is not currently supported. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
2010-03-03regulator: Add notifier event on regulator disableMark Brown1-2/+5
The intended use case is for drivers which disable regulators to save power but need to do some work to restore the hardware state when restarting. If the supplies are not actually disabled due to board limits or sharing with other active devices this notifier allows the driver to avoid unneeded reinitialisation, particularly when used with runtime PM. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
2010-03-03regulator/lp3971: Storage class should be before const qualifierTobias Klauser1-5/+5
The C99 specification states in section 6.11.5: The placement of a storage-class specifier other than at the beginning of the declaration specifiers in a declaration is an obsolescent feature. Signed-off-by: Tobias Klauser <tklauser@distanz.ch> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-03-03regulator: add voltage selection capability to mc13783 regulators v2 .Alberto Panizzo1-30/+315
This patch, complete the mc13783 regulator subsystem driver with voltage selecting capability. Main Switches (SW1AB, SW2AB) are not supported yet. version 2 diffs: - delete the "Switchers PLL" enable and multiplication factor value selecting capability because it is not a voltage or current regulator. This will be a part of Main switcher supporting task. - Correct many coding style problems pointed me out. Signed-off-by: Alberto Panizzo <maramaopercheseimorto@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-02-12regulator/lp3971: vol_map out of bounds in lp3971_{ldo,dcdc}_set_voltage()Roel Kluin1-2/+2
After `for (val = LDO_VOL_MIN_IDX; val <= LDO_VOL_MAX_IDX; val++)', if no break occurs, val reaches LDO_VOL_MIN_IDX + 1, which is out of bounds for ldo45_voltage_map[] and ldo123_voltage_map[]. Similarly BUCK_TARGET_VOL_MAX_IDX + 1 is out of bounds for buck_voltage_map[]. Signed-off-by: Roel Kluin <roel.kluin@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-02-12regulator: Fix display of null constraints for regulatorsMark Brown1-1/+1
If the regulator constraints are empty and there is no voltage reported then nothing will be added to the text displayed for the constraints, leading to random stack data being printed. This is unlikely to happen for practical regulators since most will at least report a voltage but should still be fixed. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: stable@kernel.org Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2010-02-01regulator: Specify REGULATOR_CHANGE_STATUS for WM835x LED constraintsMark Brown1-1/+3
The WM8350 LED driver needs to be able to enable and disable the regulators it is using. Previously the core wasn't properly enforcing status change constraints so the driver was able to function but this has always been intended to be required. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: stable@kernel.org Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: wm831x_reg_read() failure unnoticed in wm831x_aldo_get_mode()Roel Kluin1-1/+1
ret should be signed to notice a failure in wm831x_reg_read(). Signed-off-by: Roel Kluin <roel.kluin@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17twl-regulator: Fix reg_disable functionality for 4030 and 6030Juha Keski-Saari1-2/+2
This change makes sure all regulator group assignments are cleared on disable call Signed-off-by: Juha Keski-Saari <ext-juha.1.keski-saari@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17twl-regulator: Add turnon delay to reg_enableJuha Keski-Saari1-1/+7
This change implements a basic turnon delay in the regulator enable function to make it less probable that reg_enable returns before the regulator output is at target level Signed-off-by: Juha Keski-Saari <ext-juha.1.keski-saari@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17twl-regulator: Restore REMAP configuration in regulator probeJuha Keski-Saari1-0/+3
This change ensures the regulator REMAP register configuration is in a known state so state transitions will function as intended regardless of possible bootloader effects on it Signed-off-by: Juha Keski-Saari <ext-juha.1.keski-saari@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17twl-regulator: Add turnon-delay and REMAP config to twlreg_info structJuha Keski-Saari1-41/+62
This change includes regulator turnon delay values and the REMAP reset configuration to the twlreg_info struct, since they are basic attributes of every TWL regulator Signed-off-by: Juha Keski-Saari <ext-juha.1.keski-saari@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17twl-regulator: Define critical regulators as always_onJuha Keski-Saari1-0/+13
Defines VIO, VDD1, VDD2, VPLL1 and VINT* regulators as always_on by default since they are critical to TWL and its master's functionality and should be on in all cases where RegFW is used Signed-off-by: Juha Keski-Saari <ext-juha.1.keski-saari@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17twl-regulator: Add all twl4030 regulators to twlreg_infoJuha Keski-Saari1-9/+17
Define all twl4030 regulators in the twlreg_info table, along with appropriate VSEL tables for adjustable regulators Signed-off-by: Juha Keski-Saari <ext-juha.1.keski-saari@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: mc13783-regulator: correct the probing time.Alberto Panizzo1-2/+2
When the mc13783-regulator driver is built in kernel, probing it during the regulator subsystem initialisation result in a fault. That is because regulator subsystem is planned to be initialised very early in the boot process, before the mfd subsystem initialisation. The mc12783-regulator probing process need to access to the mc13783-core functionality to read/write mc13783 registers and so must be called after the mc13783-core driver initialisation. The way to do this is to let the kernel probe the mc13783-regulator driver when mc13783-core register his regulator subdevice. Signed-off-by: Alberto Panizzo <maramaopercheseimorto@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Fix unbalanced disables/enables in regulator_bulk_{enable,disable} error pathLars-Peter Clausen1-2/+2
Currently it is possible for regulator_bulk_{enable,disable} operations to generate unbalanced regulator_{disable,enable} calls in its error path. In case of an error only those regulators of the bulk operation which actually had been enabled/disabled should get their original state restored. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: core.c: Small coding style cleanup (indentation fixup)Stefan Roese1-6/+6
Signed-off-by: Stefan Roese <sr@denx.de> Cc: Liam Girdwood <lrg@slimlogic.co.uk> Cc: Mark Brown <broonie@opensource.wolfsonmicro.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17drivers/regulator: use PTR_ERR to get error codeJulia Lawall1-2/+2
IS_ERR returns only 1 or 0. The callsite of setup_regulators expects a negative integer in an error case. Thus, PTR_ERR has to be used to extract it. The semantic match that finds this problem is as follows: (http://coccinelle.lip6.fr/) // <smpl> @@ expression E,E1; @@ *E = IS_ERR(...) ... when != E = E1 *return E; // </smpl> Signed-off-by: Julia Lawall <julia@diku.dk> Acked-by: <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator/mc13783: various cleanupsUwe Kleine-König1-277/+112
- define needed registers and bits in the driver - properly namespace functions and structs - fix locking as required by patch "mfd/mc13783: near complete rewrite" - use platform_data as provided by "mfd/mc13783: near complete rewrite" instead of accessing struct mc13783 - struct mc13783_regulator_priv.desc is (and was) unused and so can go away - use cpp magic to initialize mc13783_regulators - bring MODULE_LICENSE in sync with actual copyright - minor style fixes This allows not including mc13783-private.h which I intend to remove soon. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Cc: Sascha Hauer <s.hauer@pengutronix.de> Cc: Liam Girdwood <lrg@slimlogic.co.uk> Cc: Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: Samuel Ortiz <sameo@linux.intel.com> Acked-by: Mark Brown <broonie@opensoruce.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator/mc13783: rename source file to match other driversUwe Kleine-König2-1/+1
One annoying thing about the old name was that the module was just called mc13783 which caused wrong expectations (at least for me). Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Cc: Sascha Hauer <s.hauer@pengutronix.de> Cc: Liam Girdwood <lrg@slimlogic.co.uk> Cc: Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: Samuel Ortiz <sameo@linux.intel.com> Acked-by: Mark Brown <broonie@opensoruce.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17Fix some AB3100 regulator issuesLinus Walleij1-21/+2
This patch will remove surplus register writes on shut down of LDO D (this magic was not needed), remove an unnecessary (!) error check and really unregister the regulators when the module is unloaded. Signed-off-by: Linus Walleij <linus.walleij@stericsson.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: keep index within bounds in da9034_get_ldo12_voltage()Roel Kluin1-1/+1
If selector equals ARRAY_SIZE(da9034_ldo12_data), that is one too large already. Signed-off-by: Roel Kluin <roel.kluin@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Ensure val is initialised in 88pm8607 choose_voltage()Mark Brown1-1/+2
If we fall through it means that we hit an unknown regulator/chip combination so set -ENOENT as an explicit flag (the return code is only used internally). Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Remove duplicate consts from ab3100Mark Brown1-5/+5
'static const int const' means the same thing as 'static const int' and sparse complains about this. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Handle regulators without suspend mode configurationMark Brown1-3/+22
Since some regulators in the system may not support suspend mode configuration we need to allow some regulators to have a missing suspend mode configuration. Do this by requiring that disabled regulators are explicitly flagged and then skip over regulators that have no state specified. Try to avoid surprises by warning the if we could set the state but no configuration is provided. This also ensures that an all zeros configuration generates a warning rather than silently disabling the regulator. Reported-by: Joonyoung Shim <jy0922.shim@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Factor out regulator name pretty printingMark Brown1-45/+38
Some of the regulator API functions have code to allow the machine constraints to override the device supplied name for the regulator in the constraints in order to help tie logging to supplies on the board and disambiguate when there is more than one regulator chip in the system. Factor this code out into a new rdev_get_name() function and use it throughout the regulator API so that we always use the same name. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Display actual settings with constraintsMark Brown1-13/+31
When voltage or current constraints are either missing or specify a range display the actual setting along with the constraints if we can. This can aid debugging of configuration problems. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Also lift apply_uV into machine_constraints_voltage()Mark Brown1-17/+18
It makes sense to do all the voltage configuration in the one split out function. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Factor out voltage constraint setupMark Brown1-27/+37
This allows constraints to take effect on regulators that support voltage setting but for which the board does not specify a voltage range (for example, because it is fixed correctly at system startup). Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Report error codes for bulk operationsMark Brown1-4/+5
If we're going to log an error we may as well log what the error code that we're failing on is. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: add 88PM8607 PMIC driverHaojian Zhuang3-0/+691
Hi Liam, Since Samuel merged a new version of mfd 88pm8607 driver, I format a new patch on regulator 88pm8607. I paste the new patch in mail. Please help to review again. And I also attach the mfd driver in mail. From: Haojian Zhuang <haojian.zhuang@marvell.com> Date: Thu, 8 Oct 2009 09:36:53 -0400 Subject: [PATCH] regulator: Add 88PM8607 PMIC driver This patch adds regulator drivers for Marvell 88PM8607 PMIC. This controller contains 3 DVC and 14 LDO regulators. This controller uses I2C interface. Signed-off-by: Haojian Zhuang <haojian.zhuang@marvell.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: Implement WM831x BuckWise DC-DC convertor DVS supportMark Brown1-18/+189
The BuckWise DC-DC convertors in WM831x devices support switching to a second output voltage using the logic level on one of the device pins. This is intended to allow rapid voltage switching for uses like cpufreq, replacing the I2C or SPI write used to configure the voltage of the regulator with a much faster GPIO status change. This is implemented by keeping the DVS voltage configured as the maximum voltage permitted for the regulator. If a request is made for the maximum voltage then the GPIO is used to switch to the DVS voltage, otherwise the normal ON voltage is updated and used. This follows the idiom used by most cpufreq drivers, which drop the minimum voltage as the core frequency is dropped but use a constant maximum - raising the voltage should normally be fast, but lowering it may be slower. Configuration of the DVS MFP on the device should be done externally, for example via OTP. Support is present in the hardware for monitoring the status of the transition using a second GPIO. This is not currently implemented but platform data is provided for it - the driver currently assumes that the device will be configured to transition immediately - but platform data is provided to reduce merge issues once it is. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Acked-by: Samuel Ortiz <sameo@linux.intel.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-17regulator: add driver for MAX8660/8661Wolfram Sang3-0/+518
Tested with a MX25-based custom board. Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-12-14regulator: Add support for twl6030 regulatorsRajendra Nayak2-22/+96
This patch updates the regulator driver to add support for TWL6030 PMIC specific LDO regulators. SMPS resources are not yet supported for TWL6030 and also .set_mode and .get_status for LDO's are yet to be implemented for TWL6030. Signed-off-by: Rajendra Nayak <rnayak@ti.com> Signed-off-by: Balaji T K <balajitk@ti.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Reviewed-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2009-12-13mfd: Rename twl4030_ routines in twl-regulator.cRajendra Nayak1-92/+97
This patch renames all twl4030_ functions to twl so that regulator driver can be reused by Triton - TWL4030 and Phoenix - TWL6030. Signed-off-by: Rajendra Nayak <rnayak@ti.com> Signed-off-by: Balaji T K <balajitk@ti.com> Signed-off-by: Santosh Shilimkar <santosh.shilimkar@ti.com> Acked-by: Kevin Hilman <khilman@deeprootsystems.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2009-12-13mfd: Rename all twl4030_i2c*Balaji T K1-4/+4
This patch renames function names like twl4030_i2c_write_u8, twl4030_i2c_read_u8 to twl_i2c_write_u8, twl_i2c_read_u8 and also common variable in twl-core.c Signed-off-by: Rajendra Nayak <rnayak@ti.com> Signed-off-by: Balaji T K <balajitk@ti.com> Signed-off-by: Santosh Shilimkar <santosh.shilimkar@ti.com> Acked-by: Kevin Hilman <khilman@deeprootsystems.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2009-12-13mfd: Rename twl4030* driver files to enable re-useSantosh Shilimkar2-2/+2
The upcoming TWL6030 is companion chip for OMAP4 like the current TWL4030 for OMAP3. The common modules like RTC, Regulator creates opportunity to re-use the most of the code from twl4030. This patch renames few common drivers twl4030* files to twl* to enable the code re-use. Signed-off-by: Rajendra Nayak <rnayak@ti.com> Signed-off-by: Balaji T K <balajitk@ti.com> Signed-off-by: Santosh Shilimkar <santosh.shilimkar@ti.com> Acked-by: Kevin Hilman <khilman@deeprootsystems.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2009-12-13mfd: Mask and unmask wm8350 IRQs on request and freeMark Brown1-3/+0
Bring the WM8350 IRQ API more in line with the generic IRQ API by masking and unmasking interrupts as they are requested and freed. This is mostly just a case of deleting the mask and unmask calls from the individual drivers. The RTC driver is changed to mask the periodic IRQ after requesting it rather than only unmasking the alarm IRQ. If the periodic IRQ fires in the period where it is reqested then there will be a spurious notification but there should be no serious consequences from this. The CODEC drive is changed to explicitly disable headphone jack detection prior to requesting the IRQs. This will avoid the IRQ firing with no jack set up. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2009-12-13mfd: Convert wm8350 IRQ handlers to irq_handler_tMark Brown1-2/+5
This is done as simple code transformation, the semantics of the IRQ API provided by the core are are still very different to those of genirq (mainly with regard to masking). Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2009-12-13mfd: Fix pcf50633-regulator drvdata usageLars-Peter Clausen1-1/+4
Currently the pcf50633-regulator driver data is set to the pcf50633 core structure, but the pcf50633-regulator remove handler assumes that it is set to the regulator device. This patch fixes the issue by accessing the pcf506533 core structure through its parent device and setting the driver data to the regulator device. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2009-12-02regulator: Initialise wm831x structure pointor for ISINK driverMark Brown1-0/+2
The version that made it into mainline missed the initialisation of the chip handle. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-11-16dereferencing freed memory regulator_fixed_voltage_remove()Dan Carpenter1-3/+2
Don't dereference drvdata after it has been freed. regards, dan carpenter Signed-off-by: Dan Carpenter <error27@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-11-16regulator: Fix check of unsigned return value and transmit errors in wm831x_gp_ldo_get_mode()Roel Kluin1-3/+3
If ret is unsigned, the checks for negative wm831x_reg_read() return values are wrong. The error value should be transmitted to its caller, e.g. wm831x_gp_ldo_get_status() which tests for a negative return value. Signed-off-by: Roel Kluin <roel.kluin@gmail.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2009-11-16regulator: Handle missing constraints in _regulator_disable()Mark Brown1-1/+2
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>