2018-11-17tipc: fix lockdep warning when reinitilaizing socketsJon Maloy1-1/+1
We get the following warning: [ 47.926140] 32-bit node address hash set to 2010a0a [ 47.927202] [ 47.927433] ================================ [ 47.928050] WARNING: inconsistent lock state [ 47.928661] 4.19.0+ #37 Tainted: G E [ 47.929346] -------------------------------- [ 47.929954] inconsistent {SOFTIRQ-ON-W} -> {IN-SOFTIRQ-W} usage. [ 47.930116] swapper/3/0 [HC0[0]:SC1[3]:HE1:SE0] takes: [ 47.930116] 00000000af8bc31e (&(&ht->lock)->rlock){+.?.}, at: rhashtable_walk_enter+0x36/0xb0 [ 47.930116] {SOFTIRQ-ON-W} state was registered at: [ 47.930116] _raw_spin_lock+0x29/0x60 [ 47.930116] rht_deferred_worker+0x556/0x810 [ 47.930116] process_one_work+0x1f5/0x540 [ 47.930116] worker_thread+0x64/0x3e0 [ 47.930116] kthread+0x112/0x150 [ 47.930116] ret_from_fork+0x3a/0x50 [ 47.930116] irq event stamp: 14044 [ 47.930116] hardirqs last enabled at (14044): [<ffffffff9a07fbba>] __local_bh_enable_ip+0x7a/0xf0 [ 47.938117] hardirqs last disabled at (14043): [<ffffffff9a07fb81>] __local_bh_enable_ip+0x41/0xf0 [ 47.938117] softirqs last enabled at (14028): [<ffffffff9a0803ee>] irq_enter+0x5e/0x60 [ 47.938117] softirqs last disabled at (14029): [<ffffffff9a0804a5>] irq_exit+0xb5/0xc0 [ 47.938117] [ 47.938117] other info that might help us debug this: [ 47.938117] Possible unsafe locking scenario: [ 47.938117] [ 47.938117] CPU0 [ 47.938117] ---- [ 47.938117] lock(&(&ht->lock)->rlock); [ 47.938117] <Interrupt> [ 47.938117] lock(&(&ht->lock)->rlock); [ 47.938117] [ 47.938117] *** DEADLOCK *** [ 47.938117] [ 47.938117] 2 locks held by swapper/3/0: [ 47.938117] #0: 0000000062c64f90 ((&d->timer)){+.-.}, at: call_timer_fn+0x5/0x280 [ 47.938117] #1: 00000000ee39619c (&(&d->lock)->rlock){+.-.}, at: tipc_disc_timeout+0xc8/0x540 [tipc] [ 47.938117] [ 47.938117] stack backtrace: [ 47.938117] CPU: 3 PID: 0 Comm: swapper/3 Tainted: G E 4.19.0+ #37 [ 47.938117] Hardware name: Bochs Bochs, BIOS Bochs 01/01/2011 [ 47.938117] Call Trace: [ 47.938117] <IRQ> [ 47.938117] dump_stack+0x5e/0x8b [ 47.938117] print_usage_bug+0x1ed/0x1ff [ 47.938117] mark_lock+0x5b5/0x630 [ 47.938117] __lock_acquire+0x4c0/0x18f0 [ 47.938117] ? lock_acquire+0xa6/0x180 [ 47.938117] lock_acquire+0xa6/0x180 [ 47.938117] ? rhashtable_walk_enter+0x36/0xb0 [ 47.938117] _raw_spin_lock+0x29/0x60 [ 47.938117] ? rhashtable_walk_enter+0x36/0xb0 [ 47.938117] rhashtable_walk_enter+0x36/0xb0 [ 47.938117] tipc_sk_reinit+0xb0/0x410 [tipc] [ 47.938117] ? mark_held_locks+0x6f/0x90 [ 47.938117] ? __local_bh_enable_ip+0x7a/0xf0 [ 47.938117] ? lockdep_hardirqs_on+0x20/0x1a0 [ 47.938117] tipc_net_finalize+0xbf/0x180 [tipc] [ 47.938117] tipc_disc_timeout+0x509/0x540 [tipc] [ 47.938117] ? call_timer_fn+0x5/0x280 [ 47.938117] ? tipc_disc_msg_xmit.isra.19+0xa0/0xa0 [tipc] [ 47.938117] ? tipc_disc_msg_xmit.isra.19+0xa0/0xa0 [tipc] [ 47.938117] call_timer_fn+0xa1/0x280 [ 47.938117] ? tipc_disc_msg_xmit.isra.19+0xa0/0xa0 [tipc] [ 47.938117] run_timer_softirq+0x1f2/0x4d0 [ 47.938117] __do_softirq+0xfc/0x413 [ 47.938117] irq_exit+0xb5/0xc0 [ 47.938117] smp_apic_timer_interrupt+0xac/0x210 [ 47.938117] apic_timer_interrupt+0xf/0x20 [ 47.938117] </IRQ> [ 47.938117] RIP: 0010:default_idle+0x1c/0x140 [ 47.938117] Code: 90 90 90 90 90 90 90 90 90 90 90 90 90 90 0f 1f 44 00 00 41 54 55 53 65 8b 2d d8 2b 74 65 0f 1f 44 00 00 e8 c6 2c 8b ff fb f4 <65> 8b 2d c5 2b 74 65 0f 1f 44 00 00 5b 5d 41 5c c3 65 8b 05 b4 2b [ 47.938117] RSP: 0018:ffffaf6ac0207ec8 EFLAGS: 00000206 ORIG_RAX: ffffffffffffff13 [ 47.938117] RAX: ffff8f5b3735e200 RBX: 0000000000000003 RCX: 0000000000000001 [ 47.938117] RDX: 0000000000000001 RSI: 0000000000000001 RDI: ffff8f5b3735e200 [ 47.938117] RBP: 0000000000000003 R08: 0000000000000001 R09: 0000000000000000 [ 47.938117] R10: 0000000000000000 R11: 0000000000000000 R12: 0000000000000000 [ 47.938117] R13: 0000000000000000 R14: ffff8f5b3735e200 R15: ffff8f5b3735e200 [ 47.938117] ? default_idle+0x1a/0x140 [ 47.938117] do_idle+0x1bc/0x280 [ 47.938117] cpu_startup_entry+0x19/0x20 [ 47.938117] start_secondary+0x187/0x1c0 [ 47.938117] secondary_startup_64+0xa4/0xb0 The reason seems to be that tipc_net_finalize()->tipc_sk_reinit() is calling the function rhashtable_walk_enter() within a timer interrupt. We fix this by executing tipc_net_finalize() in work queue context. Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-03-23tipc: obtain node identity from interface by defaultJon Maloy1-0/+1
Selecting and explicitly configuring a TIPC node identity may be unwanted in some cases. In this commit we introduce a default setting if the identity has not been set at the moment the first bearer is enabled. We do this by using a raw copy of a unique identifier from the used interface: MAC address in the case of an L2 bearer, IPv4/IPv6 address in the case of a UDP bearer. Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-03-23tipc: add 128-bit node identifierJon Maloy1-3/+1
We add a 128-bit node identity, as an alternative to the currently used 32-bit node address. For the sake of compatibility and to minimize message header changes we retain the existing 32-bit address field. When not set explicitly by the user, this field will be filled with a hash value generated from the much longer node identity, and be used as a shorthand value for the latter. We permit either the address or the identity to be set by configuration, but not both, so when the address value is set by a legacy user the corresponding 128-bit node identity is generated based on the that value. Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-02-14tipc: Introduce __tipc_nl_net_setYing Xue1-0/+1
Introduce __tipc_nl_net_set() which doesn't hold RTNL lock. Signed-off-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2016-08-18tipc: add peer removal functionalityRichard Alpe1-0/+2
Add TIPC_NL_PEER_REMOVE netlink command. This command can remove an offline peer node from the internal data structures. This will be supported by the tipc user space tool in iproute2. Signed-off-by: Richard Alpe <richard.alpe@ericsson.com> Reviewed-by: Jon Maloy <jon.maloy@ericsson.com> Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-01-12tipc: make tipc node table aware of net namespaceYing Xue1-1/+1
Global variables associated with node table are below: - node table list (node_htable) - node hash table list (tipc_node_list) - node table lock (node_list_lock) - node number counter (tipc_num_nodes) - node link number counter (tipc_num_links) To make node table support namespace, above global variables must be moved to tipc_net structure in order to keep secret for different namespaces. As a consequence, these variables are allocated and initialized when namespace is created, and deallocated when namespace is destroyed. After the change, functions associated with these variables have to utilize a namespace pointer to access them. So adding namespace pointer as a parameter of these functions is the major change made in the commit. Signed-off-by: Ying Xue <ying.xue@windriver.com> Tested-by: Tero Aho <Tero.Aho@coriant.com> Reviewed-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2015-01-12tipc: involve namespace infrastructureYing Xue1-1/+1
Involve namespace infrastructure, make the "tipc_net_id" global variable aware of per namespace, and rename it to "net_id". In order that the conversion can be successfully done, an instance of networking namespace must be passed to relevant functions, allowing them to access the "net_id" variable of per namespace. Signed-off-by: Ying Xue <ying.xue@windriver.com> Tested-by: Tero Aho <Tero.Aho@coriant.com> Reviewed-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2014-11-21tipc: add net set to new netlink apiRichard Alpe1-0/+1
Add TIPC_NL_NET_SET command to the new tipc netlink API. This command can set the network id and network (tipc) address. Netlink logical layout of network set message: -> net [ -> id ] [ -> address ] Signed-off-by: Richard Alpe <richard.alpe@ericsson.com> Reviewed-by: Erik Hugne <erik.hugne@ericsson.com> Reviewed-by: Jon Maloy <jon.maloy@ericsson.com> Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2014-11-21tipc: add net dump to new netlink apiRichard Alpe1-1/+6
Add TIPC_NL_NET_GET command to the new tipc netlink API. This command dumps the network id of the node. Netlink logical layout of returned network data: -> net -> id Signed-off-by: Richard Alpe <richard.alpe@ericsson.com> Reviewed-by: Erik Hugne <erik.hugne@ericsson.com> Reviewed-by: Jon Maloy <jon.maloy@ericsson.com> Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2014-06-27tipc: same receive code path for connection protocol and data messagesJon Paul Maloy1-2/+0
As a preparation to eliminate port_lock we need to bring reception of connection protocol messages under proper protection of bh_lock_sock or socket owner. We fix this by letting those messages follow the same code path as incoming data messages. As a side effect of this change, the last reference to the function net_route_msg() disappears, and we can eliminate that function. Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Reviewed-by: Erik Hugne <erik.hugne@ericsson.com> Reviewed-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2014-05-05tipc: convert allocations of global variables associated with bclinkYing Xue1-1/+1
Convert allocations of global variables associated with bclink from static way to dynamical way for the convenience of bclink instance initialisation. Meanwhile, this also helps TIPC support name space in the future easily. Signed-off-by: Ying Xue <ying.xue@windriver.com> Reviewed-by: Erik Hugne <erik.hugne@ericsson.com> Reviewed-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2014-04-22tipc: purge tipc_net_lock lockYing Xue1-2/+0
Now tipc routing hierarchy comprises the structures 'node', 'link'and 'bearer'. The whole hierarchy is protected by a big read/write lock, tipc_net_lock, to ensure that nothing is added or removed while code is accessing any of these structures. Obviously the locking policy makes node, link and bearer components closely bound together so that their relationship becomes unnecessarily complex. In the worst case, such locking policy not only has a negative influence on performance, but also it's prone to lead to deadlock occasionally. In order o decouple the complex relationship between bearer and node as well as link, the locking policy is adjusted as follows: - Bearer level RTNL lock is used on update side, and RCU is used on read side. Meanwhile, all bearer instances including broadcast bearer are saved into bearer_list array. - Node and link level All node instances are saved into two tipc_node_list and node_htable lists. The two lists are protected by node_list_lock on write side, and they are guarded with RCU lock on read side. All members in node structure including link instances are protected by node spin lock. - The relationship between bearer and node When link accesses bearer, it first needs to find the bearer with its bearer identity from the bearer_list array. When bearer accesses node, it can iterate the node_htable hash list with the node address to find the corresponding node. In the new locking policy, every component has its private locking solution and the relationship between bearer and node is very simple, that is, they can find each other with node address or bearer identity from node_htable hash list or bearer_list array. Until now above all changes have been done, so tipc_net_lock can be removed safely. Signed-off-by: Ying Xue <ying.xue@windriver.com> Reviewed-by: Jon Maloy <jon.maloy@ericsson.com> Reviewed-by: Erik Hugne <erik.hugne@ericsson.com> Tested-by: Erik Hugne <erik.hugne@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2012-08-20tipc: change tipc_net_start routine return value typeYing Xue1-1/+1
Since now tipc_net_start() always returns a success code - 0, its return value type should be changed from integer to void, which can avoid unnecessary check for its return value. Signed-off-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2011-03-13tipc: manually inline net_start/stop, make assoc. vars staticAllan Stephens1-2/+0
Relocates network-related variables into the subsystem files where they are now primarily used (following the recent rework of TIPC's node table), and converts globals into locals where possible. Changes the initialization of tipc_num_links from run-time to compile-time, and eliminates the net_start routine that becomes empty as a result. Also eliminates the corresponding net_stop routine by moving its (trivial) content into the one location that called the routine. Signed-off-by: Allan Stephens <allan.stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
2011-03-13tipc: Convert node object array to a hash tableAllan Stephens1-4/+0
Replaces the dynamically allocated array of pointers to the cluster's node objects with a static hash table. Hash collisions are resolved using chaining, with a typical hash chain having only a single node, to avoid degrading performance during processing of incoming packets. The conversion to a hash table reduces the memory requirements for TIPC's node table to approximately the same size it had prior to the previous commit. In addition to the hash table itself, TIPC now also maintains a linked list for the node objects, sorted by ascending network address. This list allows TIPC to continue sending responses to user space applications that request node and link information in sorted order. The list also improves performance when name table update messages are sent by making it easier to identify the nodes that must be notified. Signed-off-by: Allan Stephens <allan.stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
2011-03-13tipc: Split up unified structure of network-related variablesAllan Stephens1-14/+3
Converts the fields of the global "tipc_net" structure into individual variables. Since the struct was never referenced as a complete unit, its existence was pointless. This will facilitate upcoming changes to TIPC's node table and simpify upcoming relocation of the variables so they are only visible to the files that actually use them. This change is essentially cosmetic in nature, and doesn't affect the operation of TIPC. Signed-off-by: Allan Stephens <allan.stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
2011-03-13tipc: Fix problem with missing link in "tipc-config -l" outputAllan Stephens1-2/+2
Removes a race condition that could cause TIPC's internal counter of the number of links it has to neighboring nodes to have the incorrect value if two independent threads of control simultaneously create new link endpoints connecting to two different nodes using two different bearers. Such under counting would result in TIPC failing to list the final link(s) in its response to a configuration request to list all of the node's links. The counter is now updated atomically to ensure that simultaneous increments do not interfere with each other. Thanks go to Peter Butler <pbutler@pt.com> for his assistance in diagnosing and fixing this problem. Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
2011-01-01tipc: Remove prototype code for supporting multiple clustersAllan Stephens1-3/+5
Eliminates routines, data structures, and files that were intended to allow TIPC to support a network containing multiple clusters. Currently, TIPC supports only networks consisting of a single cluster within a single zone, so this code is unnecessary. Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2011-01-01tipc: Remove prototype code for supporting inter-cluster routingAllan Stephens1-4/+0
Eliminates routines and data structures that were intended to allow TIPC to route messages to other clusters. Currently, TIPC supports only networks consisting of a single cluster within a single zone, so this code is unnecessary. Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2011-01-01tipc: Remove prototype code for supporting multiple zonesAllan Stephens1-3/+5
Eliminates routines, data structures, and files that were intended to allows TIPC to support a network containing multiple zones. Currently, TIPC supports only networks consisting of a single cluster within a single zone, so this code is unnecessary. Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2008-09-02tipc: Don't use structure names which easily globally conflict.David S. Miller1-1/+1
Andrew Morton reported a build failure on sparc32, because TIPC uses names like "struct node" and there is a like named data structure defined in linux/node.h This just regexp replaces "struct node*" to "struct tipc_node*" to avoid this and any future similar problems. Signed-off-by: David S. Miller <davem@davemloft.net>
2008-05-21tipc: Fix initialization sequence problems when entering network modeAllan Stephens1-1/+1
This patch ensures that TIPC's topology service and configuration service are shut down before switching into "network mode". This ensures that TIPC does not mistakenly try to send unnecessary "publication withdraw" messages to other nodes before it is fully initialized for sending off-node messages. Note that the node's current network address is now updated only after the two services are shut down; this ensures that any existing connections to the topology server are terminated correctly using the old address. Signed-off-by: Allan Stephens <allan.stephens@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2007-02-10[NET] TIPC: Fix whitespace errors.YOSHIFUJI Hideaki1-2/+2
Signed-off-by: YOSHIFUJI Hideaki <yoshfuji@linux-ipv6.org> Signed-off-by: David S. Miller <davem@davemloft.net>
2006-01-18[TIPC] Avoid polluting the global namespacePer Liden1-11/+9
This patch adds a tipc_ prefix to all externally visible symbols. Signed-off-by: Per Liden <per.liden@ericsson.com>
2006-01-12[TIPC] More updates of file headersPer Liden1-1/+1
Updated copyright notice to include the year the file was actually created. Information about file creation dates was extracted from the files in the old CVS repository at tipc.sourceforge.net. Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>
2006-01-12[TIPC] Update of file headersPer Liden1-2/+1
The copyright statements from different parts of Ericsson have been merged into one. Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>
2006-01-12[TIPC] License header updatePer Liden1-9/+13
The license header in each file now more clearly state that this code is licensed under a dual BSD/GPL. Before this was only evident if you looked at the MODULE_LICENSE line in core.c. Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>
2006-01-12[TIPC] Initial mergePer Liden1-0/+63
TIPC (Transparent Inter Process Communication) is a protocol designed for intra cluster communication. For more information see http://tipc.sourceforge.net Signed-off-by: Per Liden <per.liden@nospam.ericsson.com>