From fcc082f35c6d565d351b5b89bb03a82333e9ffe8 Mon Sep 17 00:00:00 2001 From: Martin Schwidefsky Date: Mon, 4 Mar 2019 08:25:00 +0100 Subject: Revert "s390/cpum_cf: Add kernel message exaplanations" This reverts commit fb3a0b61e0d4e435016cc91575d051f841791da0. Signed-off-by: Martin Schwidefsky --- Documentation/kmsg/s390/cpum_cf_common | 36 --------------------------- Documentation/kmsg/s390/cpum_cf_diag | 45 ---------------------------------- 2 files changed, 81 deletions(-) delete mode 100644 Documentation/kmsg/s390/cpum_cf_common delete mode 100644 Documentation/kmsg/s390/cpum_cf_diag diff --git a/Documentation/kmsg/s390/cpum_cf_common b/Documentation/kmsg/s390/cpum_cf_common deleted file mode 100644 index c890a5dabdd6..000000000000 --- a/Documentation/kmsg/s390/cpum_cf_common +++ /dev/null @@ -1,36 +0,0 @@ -/*? - * Text: "CPU[%i] Counter data was lost\n" - * Severity: Error - * Parameter: - * @1: CPU identifier - * Description: - * The kernel could not extract data provided by the Performance Measurement Unit - * (PMU) fast enough, some data is overwritten. - * User action: - * None - */ - -/*? - * Text: "CPU[%i] MT counter data was lost\n" - * Severity: Warning - * Parameter: - * @1: CPU identifier - * Description: - * The kernel could not extract data provided by the Performance Measurement Unit - * (PMU) fast enough, some data is overwritten. - * User action: - * None - */ - -/*? - * Text: "Registering for CPU-measurement alerts failed with rc=%i\n" - * Severity: Error - * Parameter: - * @1: Return code of failed interrupt handler registration - * Description: - * Please insert description here - * User action: - * Reboot. If the problem persists, gather Linux debug data and report - * the problem to your support organization. - */ -/*? Text: "%s: %d output lines suppressed due to ratelimiting\n" */ diff --git a/Documentation/kmsg/s390/cpum_cf_diag b/Documentation/kmsg/s390/cpum_cf_diag deleted file mode 100644 index fd166f96ded8..000000000000 --- a/Documentation/kmsg/s390/cpum_cf_diag +++ /dev/null @@ -1,45 +0,0 @@ -/*? Text: "%s: %d output lines suppressed due to ratelimiting\n" */ -/*? Text: "cpum_cf_diag counter set compare error in set %i\n" */ -/*? Text: "Registration of s390dbf(cpum_cf_diag) failed\n" */ -/*? Text: "Registration of PMU(cpum_cf_diag) failed with rc=%i\n" */ - -/*? - * Text: "Enabling the performance measuring unit failed with rc=%x\n" - * Severity: Error - * Parameter: - * @1: Error code returned by PMU enable function - * Description: - * The CPU Measurement Facilitiy for counters needs to be enabled to extract - * counter data. - * User action: - * To use the CPU-measurement counter facility, authorize the LPAR for each - * counter set you want to use. Customize the LPAR activation profile and modify - * the Counter Facility Security Options. Then reboot. - * If the problem persists, gather Linux debug data and report the - * problem to your support organization. - */ - -/*? - * Text: "Disabling the performance measuring unit failed with rc=%x\n" - * Severity: Error - * Parameter: - * @1: Error code returned by PMU disable function - * Description: - * The CPU Measurement Facilitiy for counters is disabled to stop extraction - * of counter data. - * User action: - * Reboot. If the problem persists, gather Linux debug data and report the - * problem to your support organization. - */ - -/*? - * Text: "Insufficient memory for PMU(cpum_cf_diag) need=%zu\n" - * Severity: Error - * Parameter: - * @1: Required amount of bytes needed to store the counter sets. - * Description: - * The preallocted memory to store counter sets is too small. - * User action: - * If the problem persists, gather Linux debug data and report the - * problem to your support organization. - */ -- cgit v1.2.3-59-g8ed1b