From f164d0204b1156a7e0d8d1622c1a8d25752befec Mon Sep 17 00:00:00 2001 From: Lukas Wunner Date: Sat, 27 Oct 2018 10:36:54 +0200 Subject: can: hi311x: Use level-triggered interrupt If the hi3110 shares the SPI bus with another traffic-intensive device and packets are received in high volume (by a separate machine sending with "cangen -g 0 -i -x"), reception stops after a few minutes and the counter in /proc/interrupts stops incrementing. Bus state is "active". Bringing the interface down and back up reconvenes the reception. The issue is not observed when the hi3110 is the sole device on the SPI bus. Using a level-triggered interrupt makes the issue go away and lets the hi3110 successfully receive 2 GByte over the course of 5 days while a ks8851 Ethernet chip on the same SPI bus handles 6 GByte of traffic. Unfortunately the hi3110 datasheet is mum on the trigger type. The pin description on page 3 only specifies the polarity (active high): http://www.holtic.com/documents/371-hi-3110_v-rev-kpdf.do Cc: Mathias Duckeck Cc: Akshay Bhat Cc: Casey Fitzpatrick Signed-off-by: Lukas Wunner Cc: linux-stable Signed-off-by: Marc Kleine-Budde --- Documentation/devicetree/bindings/net/can/holt_hi311x.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) (limited to 'Documentation') diff --git a/Documentation/devicetree/bindings/net/can/holt_hi311x.txt b/Documentation/devicetree/bindings/net/can/holt_hi311x.txt index 903a78da65be..3a9926f99937 100644 --- a/Documentation/devicetree/bindings/net/can/holt_hi311x.txt +++ b/Documentation/devicetree/bindings/net/can/holt_hi311x.txt @@ -17,7 +17,7 @@ Example: reg = <1>; clocks = <&clk32m>; interrupt-parent = <&gpio4>; - interrupts = <13 IRQ_TYPE_EDGE_RISING>; + interrupts = <13 IRQ_TYPE_LEVEL_HIGH>; vdd-supply = <®5v0>; xceiver-supply = <®5v0>; }; -- cgit v1.2.3-59-g8ed1b