From 336306790b2bbf7ce837625fa3b24ba724d05838 Mon Sep 17 00:00:00 2001 From: Gwendal Grignou Date: Tue, 28 Jul 2020 13:48:25 -0700 Subject: iio: cros_ec: Set Gyroscope default frequency to 25Hz BMI160 Minimium gyroscope frequency in normal mode is 25Hz. When older EC firmware do not report their sensors frequencies, use 25Hz as the minimum for gyroscope to be sure it works on BMI160. Fixes: ae7b02ad2f32d ("iio: common: cros_ec_sensors: Expose cros_ec_sensors frequency range via iio sysfs") Signed-off-by: Gwendal Grignou Reviewed-by: Enric Balletbo i Serra Cc: Signed-off-by: Jonathan Cameron --- drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) (limited to 'drivers/iio/common') diff --git a/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c b/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c index ea480c1d4349..1bc6efa47316 100644 --- a/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c +++ b/drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c @@ -72,10 +72,13 @@ static void get_default_min_max_freq(enum motionsensor_type type, switch (type) { case MOTIONSENSE_TYPE_ACCEL: - case MOTIONSENSE_TYPE_GYRO: *min_freq = 12500; *max_freq = 100000; break; + case MOTIONSENSE_TYPE_GYRO: + *min_freq = 25000; + *max_freq = 100000; + break; case MOTIONSENSE_TYPE_MAG: *min_freq = 5000; *max_freq = 25000; -- cgit v1.2.3-59-g8ed1b