What: /sys/class/fieldbus_dev/fieldbus_devX/card_name KernelVersion: 5.1 (staging) Contact: Sven Van Asbroeck Description: Human-readable name of the Fieldbus Device. What: /sys/class/fieldbus_dev/fieldbus_devX/fieldbus_type KernelVersion: 5.1 (staging) Contact: Sven Van Asbroeck Description: The type of fieldbus implemented by this device. Possible values: 'unknown' 'profinet' What: /sys/class/fieldbus_dev/fieldbus_devX/fieldbus_id KernelVersion: 5.1 (staging) Contact: Sven Van Asbroeck Description: The unique fieldbus id associated with this device. The exact format of this id is fieldbus type dependent, e.g. a mac address for profinet. What: /sys/class/fieldbus_dev/fieldbus_devX/read_area_size KernelVersion: 5.1 (staging) Contact: Sven Van Asbroeck Description: The size, in bytes, of the Process Memory read area. Note: this area is accessible by reading from the associated character device (/dev/fieldbus_devX). What: /sys/class/fieldbus_dev/fieldbus_devX/write_area_size KernelVersion: 5.1 (staging) Contact: Sven Van Asbroeck Description: The size, in bytes, of the Process Memory write area. Note: this area is accessible by writing to the associated character device (/dev/fieldbus_devX) What: /sys/class/fieldbus_dev/fieldbus_devX/online KernelVersion: 5.1 (staging) Contact: Sven Van Asbroeck Description: Whether the fieldbus is online or offline. Possible values: '1' meaning 'online' '0' meaning 'offline' Note: an uevent is generated when this property changes. What: /sys/class/fieldbus_dev/fieldbus_devX/enabled KernelVersion: 5.1 (staging) Contact: Sven Van Asbroeck Description: Whether the device is enabled (power on) or disabled (power off). Possible values: '1' meaning enabled '0' meaning disabled Normally a r/o property, but optionally r/w: Writing '1' enables the device (power on) with default settings. Writing '0' disables the card (power off).