aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/net/marvell-armada-370-neta.txt
blob: d0cb8693963b51f447afbb9b6e6c5bd42e87f34e (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
* Marvell Armada 370 / Armada XP Ethernet Controller (NETA)

Required properties:
- compatible: "marvell,armada-370-neta" or "marvell,armada-xp-neta".
- reg: address and length of the register set for the device.
- interrupts: interrupt for the device
- phy: See ethernet.txt file in the same directory.
- phy-mode: See ethernet.txt file in the same directory
- clocks: List of clocks for this device. At least one clock is
  mandatory for the core clock. If several clocks are given, then the
  clock-names property must be used to identify them.

Optional properties:
- tx-csum-limit: maximum mtu supported by port that allow TX checksum.
  Value is presented in bytes. If not used, by default 1600B is set for
  "marvell,armada-370-neta" and 9800B for others.
- clock-names: List of names corresponding to clocks property; shall be
  "core" for core clock and "bus" for the optional bus clock.


Example:

ethernet@d0070000 {
	compatible = "marvell,armada-370-neta";
	reg = <0xd0070000 0x2500>;
	interrupts = <8>;
	clocks = <&gate_clk 4>;
	tx-csum-limit = <9800>
	status = "okay";
	phy = <&phy0>;
	phy-mode = "rgmii-id";
};