summaryrefslogtreecommitdiffstats
path: root/device
diff options
context:
space:
mode:
authorJosh Bleecher Snyder <josh@tailscale.com>2021-01-21 09:23:45 -0800
committerJosh Bleecher Snyder <josh@tailscale.com>2021-02-08 10:32:07 -0800
commit675ff32e6c29b4547e854c73b6aa6fdabe2cd0f5 (patch)
tree9082b96ab1548dc4dc07776cb4f048a1de956b20 /device
parentdevice: remove device.state.stopping from RoutineTUNEventReader (diff)
downloadwireguard-go-675ff32e6c29b4547e854c73b6aa6fdabe2cd0f5.tar.xz
wireguard-go-675ff32e6c29b4547e854c73b6aa6fdabe2cd0f5.zip
device: improve MTU change handling
The old code silently accepted negative MTUs. It also set MTUs above the maximum. It also had hard to follow deeply nested conditionals. Add more paranoid handling, and make the code more straight-line. Signed-off-by: Josh Bleecher Snyder <josh@tailscale.com>
Diffstat (limited to 'device')
-rw-r--r--device/tun.go23
1 files changed, 15 insertions, 8 deletions
diff --git a/device/tun.go b/device/tun.go
index 9ff6c23..17c2493 100644
--- a/device/tun.go
+++ b/device/tun.go
@@ -6,6 +6,7 @@
package device
import (
+ "fmt"
"sync/atomic"
"golang.zx2c4.com/wireguard/tun"
@@ -20,16 +21,22 @@ func (device *Device) RoutineTUNEventReader() {
for event := range device.tun.device.Events() {
if event&tun.EventMTUUpdate != 0 {
mtu, err := device.tun.device.MTU()
- old := atomic.LoadInt32(&device.tun.mtu)
if err != nil {
device.log.Errorf("Failed to load updated MTU of device: %v", err)
- } else if int(old) != mtu {
- if mtu+MessageTransportSize > MaxMessageSize {
- device.log.Verbosef("MTU updated: %v (too large)", mtu)
- } else {
- device.log.Verbosef("MTU updated: %v", mtu)
- }
- atomic.StoreInt32(&device.tun.mtu, int32(mtu))
+ continue
+ }
+ if mtu < 0 {
+ device.log.Errorf("MTU not updated to negative value: %v", mtu)
+ continue
+ }
+ var tooLarge string
+ if mtu > MaxContentSize {
+ tooLarge = fmt.Sprintf(" (too large, capped at %v)", MaxContentSize)
+ mtu = MaxContentSize
+ }
+ old := atomic.SwapInt32(&device.tun.mtu, int32(mtu))
+ if int(old) != mtu {
+ device.log.Verbosef("MTU updated: %v%s", mtu, tooLarge)
}
}