aboutsummaryrefslogtreecommitdiffstatshomepage
diff options
context:
space:
mode:
authorBorislav Petkov (AMD) <bp@alien8.de>2024-12-11 12:07:42 +0100
committerBorislav Petkov (AMD) <bp@alien8.de>2024-12-11 21:47:33 +0100
commit747367340ca6b5070728b86ae36ad6747f66b2fb (patch)
tree571f864ff1a4dca16c11931f9a97befe808a87ae
parentLinux 6.13-rc2 (diff)
downloadwireguard-linux-747367340ca6b5070728b86ae36ad6747f66b2fb.tar.xz
wireguard-linux-747367340ca6b5070728b86ae36ad6747f66b2fb.zip
EDAC/amd64: Simplify ECC check on unified memory controllers
The intent of the check is to see whether at least one UMC has ECC enabled. So do that instead of tracking which ones are enabled in masks which are too small in size anyway and lead to not loading the driver on Zen4 machines with UMCs enabled over UMC8. Fixes: e2be5955a886 ("EDAC/amd64: Add support for AMD Family 19h Models 10h-1Fh and A0h-AFh") Reported-by: Avadhut Naik <avadhut.naik@amd.com> Signed-off-by: Borislav Petkov (AMD) <bp@alien8.de> Tested-by: Avadhut Naik <avadhut.naik@amd.com> Reviewed-by: Avadhut Naik <avadhut.naik@amd.com> Cc: <stable@kernel.org> Link: https://lore.kernel.org/r/20241210212054.3895697-1-avadhut.naik@amd.com
Diffstat (limited to '')
-rw-r--r--drivers/edac/amd64_edac.c32
1 files changed, 10 insertions, 22 deletions
diff --git a/drivers/edac/amd64_edac.c b/drivers/edac/amd64_edac.c
index ddfbdb66b794..5d356b7c4589 100644
--- a/drivers/edac/amd64_edac.c
+++ b/drivers/edac/amd64_edac.c
@@ -3362,36 +3362,24 @@ static bool dct_ecc_enabled(struct amd64_pvt *pvt)
static bool umc_ecc_enabled(struct amd64_pvt *pvt)
{
- u8 umc_en_mask = 0, ecc_en_mask = 0;
- u16 nid = pvt->mc_node_id;
struct amd64_umc *umc;
- u8 ecc_en = 0, i;
+ bool ecc_en = false;
+ int i;
+ /* Check whether at least one UMC is enabled: */
for_each_umc(i) {
umc = &pvt->umc[i];
- /* Only check enabled UMCs. */
- if (!(umc->sdp_ctrl & UMC_SDP_INIT))
- continue;
-
- umc_en_mask |= BIT(i);
-
- if (umc->umc_cap_hi & UMC_ECC_ENABLED)
- ecc_en_mask |= BIT(i);
+ if (umc->sdp_ctrl & UMC_SDP_INIT &&
+ umc->umc_cap_hi & UMC_ECC_ENABLED) {
+ ecc_en = true;
+ break;
+ }
}
- /* Check whether at least one UMC is enabled: */
- if (umc_en_mask)
- ecc_en = umc_en_mask == ecc_en_mask;
- else
- edac_dbg(0, "Node %d: No enabled UMCs.\n", nid);
-
- edac_dbg(3, "Node %d: DRAM ECC %s.\n", nid, (ecc_en ? "enabled" : "disabled"));
+ edac_dbg(3, "Node %d: DRAM ECC %s.\n", pvt->mc_node_id, (ecc_en ? "enabled" : "disabled"));
- if (!ecc_en)
- return false;
- else
- return true;
+ return ecc_en;
}
static inline void