mdio: aspeed: Fix "Link is Down" issue
The issue happened randomly in runtime. The message "Link is Down" is popped but soon it recovered to "Link is Up". The "Link is Down" results from the incorrect read data for reading the PHY register via MDIO bus. The correct sequence for reading the data shall be: 1. fire the command 2. wait for command done (this step was missing) 3. wait for data idle 4. read data from data register Cc: stable@vger.kernel.org Fixes: f160e99462c6 ("net: phy: Add mdio-aspeed") Reviewed-by: Joel Stanley <joel@jms.id.au> Signed-off-by: Dylan Hung <dylan_hung@aspeedtech.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Reviewed-by: Russell King (Oracle) <rmk+kernel@armlinux.org.uk> Link: https://lore.kernel.org/r/20211125024432.15809-1-dylan_hung@aspeedtech.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
-rw-r--r--drivers/net/mdio/mdio-aspeed.c7
1 files changed, 7 insertions, 0 deletions
diff --git a/drivers/net/mdio/mdio-aspeed.c b/drivers/net/mdio/mdio-aspeed.c
index cad820568f75..966c3b4ad59d 100644
--- a/drivers/net/mdio/mdio-aspeed.c
+++ b/drivers/net/mdio/mdio-aspeed.c
@@ -61,6 +61,13 @@ static int aspeed_mdio_read(struct mii_bus *bus, int addr, int regnum)
iowrite32(ctrl, ctx->base + ASPEED_MDIO_CTRL);
+ rc = readl_poll_timeout(ctx->base + ASPEED_MDIO_CTRL, ctrl,
+ !(ctrl & ASPEED_MDIO_CTRL_FIRE),
+ ASPEED_MDIO_INTERVAL_US,
+ ASPEED_MDIO_TIMEOUT_US);
+ if (rc < 0)
+ return rc;
+
rc = readl_poll_timeout(ctx->base + ASPEED_MDIO_DATA, data,
data & ASPEED_MDIO_DATA_IDLE,
ASPEED_MDIO_INTERVAL_US,