-rw-r--r--Documentation/devicetree/bindings/mfd/rohm,bd71837-pmic.txt90
1 files changed, 0 insertions, 90 deletions
diff --git a/Documentation/devicetree/bindings/mfd/rohm,bd71837-pmic.txt b/Documentation/devicetree/bindings/mfd/rohm,bd71837-pmic.txt
deleted file mode 100644
index f22d74c7a8db..000000000000
--- a/Documentation/devicetree/bindings/mfd/rohm,bd71837-pmic.txt
+++ /dev/null
@@ -1,90 +0,0 @@
-* ROHM BD71837 and BD71847 Power Management Integrated Circuit bindings
-
-BD71837MWV and BD71847MWV are programmable Power Management ICs for powering
-single-core, dual-core, and quad-core SoCs such as NXP-i.MX 8M. They are
-optimized for low BOM cost and compact solution footprint. BD71837MWV
-integrates 8 Buck regulators and 7 LDOs. BD71847MWV contains 6 Buck regulators
-and 6 LDOs.
-
-Datasheet for BD71837 is available at:
-https://www.rohm.com/datasheet/BD71837MWV/bd71837mwv-e
-Datasheet for BD71847 is available at:
-https://www.rohm.com/datasheet/BD71847AMWV/bd71847amwv-e
-
-Required properties:
- - compatible : Should be "rohm,bd71837" for bd71837
- "rohm,bd71847" for bd71847.
- - reg : I2C slave address.
- - interrupt-parent : Phandle to the parent interrupt controller.
- - interrupts : The interrupt line the device is connected to.
- - clocks : The parent clock connected to PMIC. If this is missing
- 32768 KHz clock is assumed.
- - #clock-cells : Should be 0.
- - regulators: : List of child nodes that specify the regulators.
- Please see ../regulator/rohm,bd71837-regulator.txt
-
-Optional properties:
-- clock-output-names : Should contain name for output clock.
-- rohm,reset-snvs-powered : Transfer BD718x7 to SNVS state at reset.
-
-The BD718x7 supports two different HW states as reset target states. States
-are called as SNVS and READY. At READY state all the PMIC power outputs go
-down and OTP is reload. At the SNVS state all other logic and external
-devices apart from the SNVS power domain are shut off. Please refer to NXP
-i.MX8 documentation for further information regarding SNVS state. When a
-reset is done via SNVS state the PMIC OTP data is not reload. This causes
-power outputs that have been under SW control to stay down when reset has
-switched power state to SNVS. If reset is done via READY state the power
-outputs will be returned to HW control by OTP loading. Thus the reset
-target state is set to READY by default. If SNVS state is used the boot
-crucial regulators must have the regulator-always-on and regulator-boot-on
-properties set in regulator node.
-
-- rohm,short-press-ms : Short press duration in milliseconds
-- rohm,long-press-ms : Long press duration in milliseconds
-
-Configure the "short press" and "long press" timers for the power button.
-Values are rounded to what hardware supports (500ms multiple for short and
-1000ms multiple for long). If these properties are not present the existing
-configuration (from bootloader or OTP) is not touched.
-
-Example:
-
- /* external oscillator node */
- osc: oscillator {
- compatible = "fixed-clock";
- #clock-cells = <1>;
- clock-frequency = <32768>;
- clock-output-names = "osc";
- };
-
- pmic: pmic@4b {
- compatible = "rohm,bd71837";
- reg = <0x4b>;
- interrupt-parent = <&gpio1>;
- interrupts = <29 GPIO_ACTIVE_LOW>;
- interrupt-names = "irq";
- #clock-cells = <0>;
- clocks = <&osc 0>;
- clock-output-names = "bd71837-32k-out";
- rohm,reset-snvs-powered;
-
- regulators {
- buck1: BUCK1 {
- regulator-name = "buck1";
- regulator-min-microvolt = <700000>;
- regulator-max-microvolt = <1300000>;
- regulator-boot-on;
- regulator-always-on;
- regulator-ramp-delay = <1250>;
- };
- // [...]
- };
- };
-
- /* Clock consumer node */
- rtc@0 {
- compatible = "company,my-rtc";
- clock-names = "my-clock";
- clocks = <&pmic>;
- };