From c0d7eccbc76115b7eb337956c03d47d6a889cf8c Mon Sep 17 00:00:00 2001 From: Vladimir Oltean Date: Mon, 4 May 2020 01:20:27 +0300 Subject: net: mscc: ocelot: ANA_AUTOAGE_AGE_PERIOD holds a value in seconds, not ms One may notice that automatically-learnt entries 'never' expire, even though the bridge configures the address age period at 300 seconds. Actually the value written to hardware corresponds to a time interval 1000 times higher than intended, i.e. 83 hours. Fixes: a556c76adc05 ("net: mscc: Add initial Ocelot switch support") Signed-off-by: Vladimir Oltean Reviewed-by: Florian Faineli Signed-off-by: David S. Miller --- drivers/net/ethernet/mscc/ocelot.c | 11 +++++++++-- 1 file changed, 9 insertions(+), 2 deletions(-) diff --git a/drivers/net/ethernet/mscc/ocelot.c b/drivers/net/ethernet/mscc/ocelot.c index 887b3cc88354..02350c3d9d01 100644 --- a/drivers/net/ethernet/mscc/ocelot.c +++ b/drivers/net/ethernet/mscc/ocelot.c @@ -1451,8 +1451,15 @@ static void ocelot_port_attr_stp_state_set(struct ocelot *ocelot, int port, void ocelot_set_ageing_time(struct ocelot *ocelot, unsigned int msecs) { - ocelot_write(ocelot, ANA_AUTOAGE_AGE_PERIOD(msecs / 2), - ANA_AUTOAGE); + unsigned int age_period = ANA_AUTOAGE_AGE_PERIOD(msecs / 2000); + + /* Setting AGE_PERIOD to zero effectively disables automatic aging, + * which is clearly not what our intention is. So avoid that. + */ + if (!age_period) + age_period = 1; + + ocelot_rmw(ocelot, age_period, ANA_AUTOAGE_AGE_PERIOD_M, ANA_AUTOAGE); } EXPORT_SYMBOL(ocelot_set_ageing_time); -- cgit v1.2.3-59-g8ed1b