From a7ac6570f67061576c51c5204a51f034af54adec Mon Sep 17 00:00:00 2001 From: Florian Fainelli Date: Wed, 11 Oct 2017 17:53:10 -0700 Subject: dt-bindings: phy: Add RX equalizer properties for Broadcom SATA PHY Define two new properties: brcm,rx-aeq-mode which allows configuring the SATA PHY RX equalizers and when "manual" is used, brcm,rx-aeq can be used to set the exact value. Signed-off-by: Florian Fainelli Acked-by: Rob Herring Signed-off-by: Kishon Vijay Abraham I --- Documentation/devicetree/bindings/phy/brcm-sata-phy.txt | 11 ++++++++++- 1 file changed, 10 insertions(+), 1 deletion(-) (limited to 'Documentation/devicetree/bindings/phy/brcm-sata-phy.txt') diff --git a/Documentation/devicetree/bindings/phy/brcm-sata-phy.txt b/Documentation/devicetree/bindings/phy/brcm-sata-phy.txt index 97977cd29a98..0aced97d8092 100644 --- a/Documentation/devicetree/bindings/phy/brcm-sata-phy.txt +++ b/Documentation/devicetree/bindings/phy/brcm-sata-phy.txt @@ -27,7 +27,16 @@ Sub-nodes optional properties: This property is not applicable for "brcm,iproc-ns2-sata-phy", "brcm,iproc-nsp-sata-phy" and "brcm,iproc-sr-sata-phy". -Example: +- brcm,rxaeq-mode: string that indicates the desired RX equalizer + mode, possible values are: + "off" (equivalent to not specifying the property) + "auto" + "manual" (brcm,rxaeq-value is used in that case) + +- brcm,rxaeq-value: when 'rxaeq-mode' is set to "manual", provides the RX + equalizer value that should be used. Allowed range is 0..63. + +Example sata-phy@f0458100 { compatible = "brcm,bcm7445-sata-phy", "brcm,phy-sata3"; reg = <0xf0458100 0x1e00>, <0xf045804c 0x10>; -- cgit v1.2.3-59-g8ed1b