aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorAngel Iglesias <ang.iglesiasg@gmail.com>2022-09-13 01:46:42 +0200
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2022-09-21 18:42:53 +0100
commit83cb40beaefaf59b224efdabecaac611b783da74 (patch)
tree3181602f8ffa78eb291bb3034e993ae75e374ae2
parentiio: pressure: bmp280: use FIELD_GET, FIELD_PREP and GENMASK (diff)
downloadlinux-dev-83cb40beaefaf59b224efdabecaac611b783da74.tar.xz
linux-dev-83cb40beaefaf59b224efdabecaac611b783da74.zip
iio: pressure: bmp280: Simplify bmp280 calibration data reading
On bmp280 and bme280, the temperature and pressure calibration parameters are available on a contiguous memory region. Considering this arrangement, simplified the calibration reading function by using only one buffer to read in batch temperature and pressure registers. Signed-off-by: Angel Iglesias <ang.iglesiasg@gmail.com> Link: https://lore.kernel.org/r/96d81282c95006d857f4d836d2ff3ee0740a85a0.1663025017.git.ang.iglesiasg@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
-rw-r--r--drivers/iio/pressure/bmp280-core.c58
-rw-r--r--drivers/iio/pressure/bmp280.h3
2 files changed, 26 insertions, 35 deletions
diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index 74f273b07f33..c86dae3c5cec 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -134,8 +134,7 @@ struct bmp280_chip_info {
* These enums are used for indexing into the array of compensation
* parameters for BMP280.
*/
-enum { T1, T2, T3 };
-enum { P1, P2, P3, P4, P5, P6, P7, P8, P9 };
+enum { T1, T2, T3, P1, P2, P3, P4, P5, P6, P7, P8, P9 };
static const struct iio_chan_spec bmp280_channels[] = {
{
@@ -159,8 +158,7 @@ static int bmp280_read_calib(struct bmp280_data *data,
struct bmp280_calib *calib,
unsigned int chip)
{
- __le16 p_buf[BMP280_COMP_PRESS_REG_COUNT / 2];
- __le16 t_buf[BMP280_COMP_TEMP_REG_COUNT / 2];
+ __le16 c_buf[BMP280_CONTIGUOUS_CALIB_REGS / 2];
struct device *dev = data->dev;
unsigned int tmp;
__le16 l16;
@@ -168,43 +166,33 @@ static int bmp280_read_calib(struct bmp280_data *data,
int ret;
- /* Read temperature calibration values. */
+ /* Read temperature and pressure calibration values. */
ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_TEMP_START,
- t_buf, BMP280_COMP_TEMP_REG_COUNT);
+ c_buf, sizeof(c_buf));
if (ret < 0) {
dev_err(data->dev,
- "failed to read temperature calibration parameters\n");
+ "failed to read temperature and pressure calibration parameters\n");
return ret;
}
- /* Toss the temperature calibration data into the entropy pool */
- add_device_randomness(t_buf, sizeof(t_buf));
-
- calib->T1 = le16_to_cpu(t_buf[T1]);
- calib->T2 = le16_to_cpu(t_buf[T2]);
- calib->T3 = le16_to_cpu(t_buf[T3]);
-
- /* Read pressure calibration values. */
- ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_PRESS_START,
- p_buf, BMP280_COMP_PRESS_REG_COUNT);
- if (ret < 0) {
- dev_err(data->dev,
- "failed to read pressure calibration parameters\n");
- return ret;
- }
-
- /* Toss the pressure calibration data into the entropy pool */
- add_device_randomness(p_buf, sizeof(p_buf));
-
- calib->P1 = le16_to_cpu(p_buf[P1]);
- calib->P2 = le16_to_cpu(p_buf[P2]);
- calib->P3 = le16_to_cpu(p_buf[P3]);
- calib->P4 = le16_to_cpu(p_buf[P4]);
- calib->P5 = le16_to_cpu(p_buf[P5]);
- calib->P6 = le16_to_cpu(p_buf[P6]);
- calib->P7 = le16_to_cpu(p_buf[P7]);
- calib->P8 = le16_to_cpu(p_buf[P8]);
- calib->P9 = le16_to_cpu(p_buf[P9]);
+ /* Toss the temperature and pressure calibration data into the entropy pool */
+ add_device_randomness(c_buf, sizeof(c_buf));
+
+ /* Parse temperature calibration values. */
+ calib->T1 = le16_to_cpu(c_buf[T1]);
+ calib->T2 = le16_to_cpu(c_buf[T2]);
+ calib->T3 = le16_to_cpu(c_buf[T3]);
+
+ /* Parse pressure calibration values. */
+ calib->P1 = le16_to_cpu(c_buf[P1]);
+ calib->P2 = le16_to_cpu(c_buf[P2]);
+ calib->P3 = le16_to_cpu(c_buf[P3]);
+ calib->P4 = le16_to_cpu(c_buf[P4]);
+ calib->P5 = le16_to_cpu(c_buf[P5]);
+ calib->P6 = le16_to_cpu(c_buf[P6]);
+ calib->P7 = le16_to_cpu(c_buf[P7]);
+ calib->P8 = le16_to_cpu(c_buf[P8]);
+ calib->P9 = le16_to_cpu(c_buf[P9]);
/*
* Read humidity calibration values.
diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h
index 4a501836d27a..03a539223417 100644
--- a/drivers/iio/pressure/bmp280.h
+++ b/drivers/iio/pressure/bmp280.h
@@ -37,6 +37,9 @@
#define BMP280_COMP_H5_MASK GENMASK(15, 4)
+#define BMP280_CONTIGUOUS_CALIB_REGS (BMP280_COMP_TEMP_REG_COUNT + \
+ BMP280_COMP_PRESS_REG_COUNT)
+
#define BMP280_FILTER_MASK GENMASK(4, 2)
#define BMP280_FILTER_OFF 0
#define BMP280_FILTER_2X 1