aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
diff options
context:
space:
mode:
authorNaveen Krishna Chatradhi <ch.naveen@samsung.com>2013-12-19 11:36:08 +0530
committerEduardo Valentin <edubezval@gmail.com>2014-05-06 14:51:32 -0400
commit9025d563cd9bd141a7b7f2095b6a760cd9d83a4e (patch)
tree412d7be9dc372c690da0ccd8497c00b5aeafdff2 /Documentation/devicetree/bindings/thermal/exynos-thermal.txt
parentthermal: samsung: replace inten_ bit fields with intclr_ (diff)
downloadlinux-dev-9025d563cd9bd141a7b7f2095b6a760cd9d83a4e.tar.xz
linux-dev-9025d563cd9bd141a7b7f2095b6a760cd9d83a4e.zip
thermal: samsung: change base_common to more meaningful base_second
On Exynos5440 and Exynos5420 there are registers common across the TMU channels. To support that, we introduced a ADDRESS_MULTIPLE flag in the driver and the 2nd set of register base and size are provided in the "reg" property of the node. As per Amit's suggestion, this patch changes the base_common to base_second and SHARED_MEMORY to ADDRESS_MULTIPLE. Signed-off-by: Naveen Krishna Chatradhi <ch.naveen@samsung.com> Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com> Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com> Reviewed-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'Documentation/devicetree/bindings/thermal/exynos-thermal.txt')
-rw-r--r--Documentation/devicetree/bindings/thermal/exynos-thermal.txt4
1 files changed, 2 insertions, 2 deletions
diff --git a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt b/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
index 284f5300fd8b..a1aa6023d248 100644
--- a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
@@ -11,8 +11,8 @@
- reg : Address range of the thermal registers. For soc's which has multiple
instances of TMU and some registers are shared across all TMU's like
interrupt related then 2 set of register has to supplied. First set
- belongs to each instance of TMU and second set belongs to common TMU
- registers.
+ belongs to register set of TMU instance and second set belongs to
+ registers shared with the TMU instance.
- interrupts : Should contain interrupt for thermal system
- clocks : The main clock for TMU device
- clock-names : Thermal system clock name