aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/lm95245
diff options
context:
space:
mode:
authorMauro Carvalho Chehab <mchehab+samsung@kernel.org>2019-04-17 06:46:29 -0300
committerGuenter Roeck <linux@roeck-us.net>2019-04-17 10:37:23 -0700
commit7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7 (patch)
tree9db30159bd32bec125c7d49e80a79bb7c4da0c8e /Documentation/hwmon/lm95245
parentdocs: hwmon: convert remaining files to ReST format (diff)
downloadlinux-dev-7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7.tar.xz
linux-dev-7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7.zip
docs: hwmon: Add an index file and rename docs to *.rst
Now that all files were converted to ReST format, rename them and add an index. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/lm95245')
-rw-r--r--Documentation/hwmon/lm9524548
1 files changed, 0 insertions, 48 deletions
diff --git a/Documentation/hwmon/lm95245 b/Documentation/hwmon/lm95245
deleted file mode 100644
index 566d1dc8c5a6..000000000000
--- a/Documentation/hwmon/lm95245
+++ /dev/null
@@ -1,48 +0,0 @@
-Kernel driver lm95245
-=====================
-
-Supported chips:
-
- * TI LM95235
-
- Addresses scanned: I2C 0x18, 0x29, 0x4c
-
- Datasheet: Publicly available at the TI website
-
- http://www.ti.com/lit/ds/symlink/lm95235.pdf
-
- * TI / National Semiconductor LM95245
-
- Addresses scanned: I2C 0x18, 0x19, 0x29, 0x4c, 0x4d
-
- Datasheet: Publicly available at the TI website
-
- http://www.ti.com/lit/ds/symlink/lm95245.pdf
-
-Author: Alexander Stein <alexander.stein@systec-electronic.com>
-
-Description
------------
-
-LM95235 and LM95245 are 11-bit digital temperature sensors with a 2-wire System
-Management Bus (SMBus) interface and TruTherm technology that can monitor
-the temperature of a remote diode as well as its own temperature.
-The chips can be used to very accurately monitor the temperature of
-external devices such as microprocessors.
-
-All temperature values are given in millidegrees Celsius. Local temperature
-is given within a range of -127 to +127.875 degrees. Remote temperatures are
-given within a range of -127 to +255 degrees. Resolution depends on
-temperature input and range.
-
-Each sensor has its own critical limit. Additionally, there is a relative
-hysteresis value common to both critical limits. To make life easier to
-user-space applications, two absolute values are exported, one for each
-channel, but these values are of course linked. Only the local hysteresis
-can be set from user-space, and the same delta applies to the remote
-hysteresis.
-
-The lm95245 driver can change its update interval to a fixed set of values.
-It will round up to the next selectable interval. See the datasheet for exact
-values. Reading sensor values more often will do no harm, but will return
-'old' values.