aboutsummaryrefslogtreecommitdiffstats
path: root/arch/arm/boot/dts/exynos4412-midas.dtsi
diff options
context:
space:
mode:
authorKrzysztof Kozlowski <krzk@kernel.org>2020-08-30 15:51:53 +0200
committerKrzysztof Kozlowski <krzk@kernel.org>2020-09-02 17:46:28 +0200
commite4cf0a4dba7f0bd579dc96f24d8e6134995005c5 (patch)
treee2cd21881176a39ba1a9a3790514e9a393e38bcf /arch/arm/boot/dts/exynos4412-midas.dtsi
parentARM: dts: exynos: Add S5M8767 clocks for RTC in Exynos4412 Origen (diff)
downloadlinux-dev-e4cf0a4dba7f0bd579dc96f24d8e6134995005c5.tar.xz
linux-dev-e4cf0a4dba7f0bd579dc96f24d8e6134995005c5.zip
ARM: dts: exynos: Override thermal by label in Midas
Using full paths to extend or override a device tree node is error prone since if there was a typo error, a new node will be created instead of extending the node as it was desired. This will lead to run-time errors that could be hard to detect. A mistyped label on the other hand, will cause a dtc compile error (during build time). Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org> Link: https://lore.kernel.org/r/20200830135200.24304-26-krzk@kernel.org
Diffstat (limited to 'arch/arm/boot/dts/exynos4412-midas.dtsi')
-rw-r--r--arch/arm/boot/dts/exynos4412-midas.dtsi34
1 files changed, 15 insertions, 19 deletions
diff --git a/arch/arm/boot/dts/exynos4412-midas.dtsi b/arch/arm/boot/dts/exynos4412-midas.dtsi
index 32d2e539b2dd..7e7c243ff196 100644
--- a/arch/arm/boot/dts/exynos4412-midas.dtsi
+++ b/arch/arm/boot/dts/exynos4412-midas.dtsi
@@ -319,25 +319,6 @@
pulldown-ohm = <100000>; /* 100K */
io-channels = <&adc 2>; /* Battery temperature */
};
-
- thermal-zones {
- cpu_thermal: cpu-thermal {
- cooling-maps {
- map0 {
- /* Corresponds to 800MHz at freq_table */
- cooling-device = <&cpu0 7 7>, <&cpu1 7 7>,
- <&cpu2 7 7>, <&cpu3 7 7>;
- };
- map1 {
- /* Corresponds to 200MHz at freq_table */
- cooling-device = <&cpu0 13 13>,
- <&cpu1 13 13>,
- <&cpu2 13 13>,
- <&cpu3 13 13>;
- };
- };
- };
- };
};
&adc {
@@ -406,6 +387,21 @@
cpu0-supply = <&buck2_reg>;
};
+&cpu_thermal {
+ cooling-maps {
+ map0 {
+ /* Corresponds to 800MHz at freq_table */
+ cooling-device = <&cpu0 7 7>, <&cpu1 7 7>,
+ <&cpu2 7 7>, <&cpu3 7 7>;
+ };
+ map1 {
+ /* Corresponds to 200MHz at freq_table */
+ cooling-device = <&cpu0 13 13>, <&cpu1 13 13>,
+ <&cpu2 13 13>, <&cpu3 13 13>;
+ };
+ };
+};
+
&csis_0 {
status = "okay";