aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/cpufreq
diff options
context:
space:
mode:
authorViresh Kumar <viresh.kumar@linaro.org>2017-12-05 11:02:43 +0530
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2017-12-07 22:52:01 +0100
commitf5f263fed66f75a4482d7ad49392b4283a05885a (patch)
tree230438b70d7eae17d8f4cd17bec052be342c19c4 /drivers/cpufreq
parentLinux 4.15-rc2 (diff)
downloadlinux-dev-f5f263fed66f75a4482d7ad49392b4283a05885a.tar.xz
linux-dev-f5f263fed66f75a4482d7ad49392b4283a05885a.zip
cpu_cooling: Make of_cpufreq_power_cooling_register() parse DT
All the callers of of_cpufreq_power_cooling_register() have almost identical code and it makes more sense to move that code into the helper as its all about reading DT properties. This got rid of lot of redundant code. Acked-by: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r--drivers/cpufreq/arm_big_little.c23
-rw-r--r--drivers/cpufreq/cpufreq-dt.c27
-rw-r--r--drivers/cpufreq/mediatek-cpufreq.c22
-rw-r--r--drivers/cpufreq/qoriq-cpufreq.c14
4 files changed, 4 insertions, 82 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c
index 65ec5f01aa8d..3d5ed4ef3927 100644
--- a/drivers/cpufreq/arm_big_little.c
+++ b/drivers/cpufreq/arm_big_little.c
@@ -526,34 +526,13 @@ static int bL_cpufreq_exit(struct cpufreq_policy *policy)
static void bL_cpufreq_ready(struct cpufreq_policy *policy)
{
- struct device *cpu_dev = get_cpu_device(policy->cpu);
int cur_cluster = cpu_to_cluster(policy->cpu);
- struct device_node *np;
/* Do not register a cpu_cooling device if we are in IKS mode */
if (cur_cluster >= MAX_CLUSTERS)
return;
- np = of_node_get(cpu_dev->of_node);
- if (WARN_ON(!np))
- return;
-
- if (of_find_property(np, "#cooling-cells", NULL)) {
- u32 power_coefficient = 0;
-
- of_property_read_u32(np, "dynamic-power-coefficient",
- &power_coefficient);
-
- cdev[cur_cluster] = of_cpufreq_power_cooling_register(np,
- policy, power_coefficient, NULL);
- if (IS_ERR(cdev[cur_cluster])) {
- dev_err(cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(cdev[cur_cluster]));
- cdev[cur_cluster] = NULL;
- }
- }
- of_node_put(np);
+ cdev[cur_cluster] = of_cpufreq_power_cooling_register(policy);
}
static struct cpufreq_driver bL_cpufreq_driver = {
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index 545946ad0752..1e7bec7694ab 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -319,33 +319,8 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
static void cpufreq_ready(struct cpufreq_policy *policy)
{
struct private_data *priv = policy->driver_data;
- struct device_node *np = of_node_get(priv->cpu_dev->of_node);
- if (WARN_ON(!np))
- return;
-
- /*
- * For now, just loading the cooling device;
- * thermal DT code takes care of matching them.
- */
- if (of_find_property(np, "#cooling-cells", NULL)) {
- u32 power_coefficient = 0;
-
- of_property_read_u32(np, "dynamic-power-coefficient",
- &power_coefficient);
-
- priv->cdev = of_cpufreq_power_cooling_register(np,
- policy, power_coefficient, NULL);
- if (IS_ERR(priv->cdev)) {
- dev_err(priv->cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(priv->cdev));
-
- priv->cdev = NULL;
- }
- }
-
- of_node_put(np);
+ priv->cdev = of_cpufreq_power_cooling_register(policy);
}
static struct cpufreq_driver dt_cpufreq_driver = {
diff --git a/drivers/cpufreq/mediatek-cpufreq.c b/drivers/cpufreq/mediatek-cpufreq.c
index e0d5090b303d..6ff783e1b18a 100644
--- a/drivers/cpufreq/mediatek-cpufreq.c
+++ b/drivers/cpufreq/mediatek-cpufreq.c
@@ -310,28 +310,8 @@ static int mtk_cpufreq_set_target(struct cpufreq_policy *policy,
static void mtk_cpufreq_ready(struct cpufreq_policy *policy)
{
struct mtk_cpu_dvfs_info *info = policy->driver_data;
- struct device_node *np = of_node_get(info->cpu_dev->of_node);
- u32 capacitance = 0;
- if (WARN_ON(!np))
- return;
-
- if (of_find_property(np, "#cooling-cells", NULL)) {
- of_property_read_u32(np, DYNAMIC_POWER, &capacitance);
-
- info->cdev = of_cpufreq_power_cooling_register(np,
- policy, capacitance, NULL);
-
- if (IS_ERR(info->cdev)) {
- dev_err(info->cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(info->cdev));
-
- info->cdev = NULL;
- }
- }
-
- of_node_put(np);
+ info->cdev = of_cpufreq_power_cooling_register(policy);
}
static int mtk_cpu_dvfs_info_init(struct mtk_cpu_dvfs_info *info, int cpu)
diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c
index 4ada55b8856e..3a665c18e14e 100644
--- a/drivers/cpufreq/qoriq-cpufreq.c
+++ b/drivers/cpufreq/qoriq-cpufreq.c
@@ -275,20 +275,8 @@ static int qoriq_cpufreq_target(struct cpufreq_policy *policy,
static void qoriq_cpufreq_ready(struct cpufreq_policy *policy)
{
struct cpu_data *cpud = policy->driver_data;
- struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
- if (of_find_property(np, "#cooling-cells", NULL)) {
- cpud->cdev = of_cpufreq_cooling_register(np, policy);
-
- if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) {
- pr_err("cpu%d is not running as cooling device: %ld\n",
- policy->cpu, PTR_ERR(cpud->cdev));
-
- cpud->cdev = NULL;
- }
- }
-
- of_node_put(np);
+ cpud->cdev = of_cpufreq_power_cooling_register(policy);
}
static struct cpufreq_driver qoriq_cpufreq_driver = {