diff options
author | Suzuki K Poulose <suzuki.poulose@arm.com> | 2019-06-19 13:52:51 -0600 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2019-06-20 07:56:10 +0200 |
commit | 22aa495a64770f39b0c29d7bda9b777d487e79bd (patch) | |
tree | c53d333d8d64fc52bb53c934ce918f53a2d99201 /drivers/hwtracing/coresight/coresight-platform.c | |
parent | coresight: tmc-etr: Rearrange probing default buffer size (diff) | |
download | linux-dev-22aa495a64770f39b0c29d7bda9b777d487e79bd.tar.xz linux-dev-22aa495a64770f39b0c29d7bda9b777d487e79bd.zip |
coresight: Rename of_coresight to coresight-platform
Rename the firmware handling file to a more generic
name, in preparation for adding ACPI support. Right now
we only support DT and we have all the platform handling
code in of_coresight.c. Let us rename the file to
coresight-platform.c in order to keep the platform handling
in a single place for DT and the upcoming ACPI support.
Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com>
Signed-off-by: Mathieu Poirier <mathieu.poirier@linaro.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers/hwtracing/coresight/coresight-platform.c')
-rw-r--r-- | drivers/hwtracing/coresight/coresight-platform.c | 298 |
1 files changed, 298 insertions, 0 deletions
diff --git a/drivers/hwtracing/coresight/coresight-platform.c b/drivers/hwtracing/coresight/coresight-platform.c new file mode 100644 index 000000000000..514cc2b67c36 --- /dev/null +++ b/drivers/hwtracing/coresight/coresight-platform.c @@ -0,0 +1,298 @@ +// SPDX-License-Identifier: GPL-2.0 +/* + * Copyright (c) 2012, The Linux Foundation. All rights reserved. + */ + +#include <linux/types.h> +#include <linux/err.h> +#include <linux/slab.h> +#include <linux/clk.h> +#include <linux/of.h> +#include <linux/of_address.h> +#include <linux/of_graph.h> +#include <linux/of_platform.h> +#include <linux/platform_device.h> +#include <linux/amba/bus.h> +#include <linux/coresight.h> +#include <linux/cpumask.h> +#include <asm/smp_plat.h> + +#ifdef CONFIG_OF +static int of_dev_node_match(struct device *dev, void *data) +{ + return dev->of_node == data; +} + +static struct device * +of_coresight_get_endpoint_device(struct device_node *endpoint) +{ + struct device *dev = NULL; + + /* + * If we have a non-configurable replicator, it will be found on the + * platform bus. + */ + dev = bus_find_device(&platform_bus_type, NULL, + endpoint, of_dev_node_match); + if (dev) + return dev; + + /* + * We have a configurable component - circle through the AMBA bus + * looking for the device that matches the endpoint node. + */ + return bus_find_device(&amba_bustype, NULL, + endpoint, of_dev_node_match); +} + +static inline bool of_coresight_legacy_ep_is_input(struct device_node *ep) +{ + return of_property_read_bool(ep, "slave-mode"); +} + +static void of_coresight_get_ports_legacy(const struct device_node *node, + int *nr_inport, int *nr_outport) +{ + struct device_node *ep = NULL; + int in = 0, out = 0; + + do { + ep = of_graph_get_next_endpoint(node, ep); + if (!ep) + break; + + if (of_coresight_legacy_ep_is_input(ep)) + in++; + else + out++; + + } while (ep); + + *nr_inport = in; + *nr_outport = out; +} + +static struct device_node *of_coresight_get_port_parent(struct device_node *ep) +{ + struct device_node *parent = of_graph_get_port_parent(ep); + + /* + * Skip one-level up to the real device node, if we + * are using the new bindings. + */ + if (of_node_name_eq(parent, "in-ports") || + of_node_name_eq(parent, "out-ports")) + parent = of_get_next_parent(parent); + + return parent; +} + +static inline struct device_node * +of_coresight_get_input_ports_node(const struct device_node *node) +{ + return of_get_child_by_name(node, "in-ports"); +} + +static inline struct device_node * +of_coresight_get_output_ports_node(const struct device_node *node) +{ + return of_get_child_by_name(node, "out-ports"); +} + +static inline int +of_coresight_count_ports(struct device_node *port_parent) +{ + int i = 0; + struct device_node *ep = NULL; + + while ((ep = of_graph_get_next_endpoint(port_parent, ep))) + i++; + return i; +} + +static void of_coresight_get_ports(const struct device_node *node, + int *nr_inport, int *nr_outport) +{ + struct device_node *input_ports = NULL, *output_ports = NULL; + + input_ports = of_coresight_get_input_ports_node(node); + output_ports = of_coresight_get_output_ports_node(node); + + if (input_ports || output_ports) { + if (input_ports) { + *nr_inport = of_coresight_count_ports(input_ports); + of_node_put(input_ports); + } + if (output_ports) { + *nr_outport = of_coresight_count_ports(output_ports); + of_node_put(output_ports); + } + } else { + /* Fall back to legacy DT bindings parsing */ + of_coresight_get_ports_legacy(node, nr_inport, nr_outport); + } +} + +static int of_coresight_alloc_memory(struct device *dev, + struct coresight_platform_data *pdata) +{ + if (pdata->nr_outport) { + pdata->conns = devm_kzalloc(dev, pdata->nr_outport * + sizeof(*pdata->conns), + GFP_KERNEL); + if (!pdata->conns) + return -ENOMEM; + } + + return 0; +} + +int of_coresight_get_cpu(const struct device_node *node) +{ + int cpu; + struct device_node *dn; + + dn = of_parse_phandle(node, "cpu", 0); + /* Affinity defaults to CPU0 */ + if (!dn) + return 0; + cpu = of_cpu_node_to_id(dn); + of_node_put(dn); + + /* Affinity to CPU0 if no cpu nodes are found */ + return (cpu < 0) ? 0 : cpu; +} +EXPORT_SYMBOL_GPL(of_coresight_get_cpu); + +/* + * of_coresight_parse_endpoint : Parse the given output endpoint @ep + * and fill the connection information in @conn + * + * Parses the local port, remote device name and the remote port. + * + * Returns : + * 1 - If the parsing is successful and a connection record + * was created for an output connection. + * 0 - If the parsing completed without any fatal errors. + * -Errno - Fatal error, abort the scanning. + */ +static int of_coresight_parse_endpoint(struct device *dev, + struct device_node *ep, + struct coresight_connection *conn) +{ + int ret = 0; + struct of_endpoint endpoint, rendpoint; + struct device_node *rparent = NULL; + struct device_node *rep = NULL; + struct device *rdev = NULL; + + do { + /* Parse the local port details */ + if (of_graph_parse_endpoint(ep, &endpoint)) + break; + /* + * Get a handle on the remote endpoint and the device it is + * attached to. + */ + rep = of_graph_get_remote_endpoint(ep); + if (!rep) + break; + rparent = of_coresight_get_port_parent(rep); + if (!rparent) + break; + if (of_graph_parse_endpoint(rep, &rendpoint)) + break; + + /* If the remote device is not available, defer probing */ + rdev = of_coresight_get_endpoint_device(rparent); + if (!rdev) { + ret = -EPROBE_DEFER; + break; + } + + conn->outport = endpoint.port; + conn->child_name = devm_kstrdup(dev, + dev_name(rdev), + GFP_KERNEL); + conn->child_port = rendpoint.port; + /* Connection record updated */ + ret = 1; + } while (0); + + of_node_put(rparent); + of_node_put(rep); + put_device(rdev); + + return ret; +} + +struct coresight_platform_data * +of_get_coresight_platform_data(struct device *dev, + const struct device_node *node) +{ + int ret = 0; + struct coresight_platform_data *pdata; + struct coresight_connection *conn; + struct device_node *ep = NULL; + const struct device_node *parent = NULL; + bool legacy_binding = false; + + pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL); + if (!pdata) + return ERR_PTR(-ENOMEM); + + /* Use device name as sysfs handle */ + pdata->name = dev_name(dev); + pdata->cpu = of_coresight_get_cpu(node); + + /* Get the number of input and output port for this component */ + of_coresight_get_ports(node, &pdata->nr_inport, &pdata->nr_outport); + + /* If there are no output connections, we are done */ + if (!pdata->nr_outport) + return pdata; + + ret = of_coresight_alloc_memory(dev, pdata); + if (ret) + return ERR_PTR(ret); + + parent = of_coresight_get_output_ports_node(node); + /* + * If the DT uses obsoleted bindings, the ports are listed + * under the device and we need to filter out the input + * ports. + */ + if (!parent) { + legacy_binding = true; + parent = node; + dev_warn_once(dev, "Uses obsolete Coresight DT bindings\n"); + } + + conn = pdata->conns; + + /* Iterate through each output port to discover topology */ + while ((ep = of_graph_get_next_endpoint(parent, ep))) { + /* + * Legacy binding mixes input/output ports under the + * same parent. So, skip the input ports if we are dealing + * with legacy binding, as they processed with their + * connected output ports. + */ + if (legacy_binding && of_coresight_legacy_ep_is_input(ep)) + continue; + + ret = of_coresight_parse_endpoint(dev, ep, conn); + switch (ret) { + case 1: + conn++; /* Fall through */ + case 0: + break; + default: + return ERR_PTR(ret); + } + } + + return pdata; +} +EXPORT_SYMBOL_GPL(of_get_coresight_platform_data); +#endif |