aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/infiniband
diff options
context:
space:
mode:
authorMajd Dibbiny <majd@mellanox.com>2017-05-30 09:58:06 +0300
committerDoug Ledford <dledford@redhat.com>2017-07-17 21:21:25 -0400
commit8fe8bacb92f249c91a1407b48aa1cb98067fe19d (patch)
tree095c7eea7f03591ca4c5a6615e7257c31c80be41 /drivers/infiniband
parentIB/mlx5: Clean mr_cache debugfs in case of failure (diff)
downloadlinux-dev-8fe8bacb92f249c91a1407b48aa1cb98067fe19d.tar.xz
linux-dev-8fe8bacb92f249c91a1407b48aa1cb98067fe19d.zip
IB/core: Add ordered workqueue for RoCE GID management
Currently the RoCE GID management uses the ib_wq to do add and delete new GIDs according to the netdev events. The ib_wq isn't an ordered workqueue and thus two work elements can be executed concurrently which will result in unexpected behavior and inconsistency of the GIDs cache content. Example: ifconfig eth1 11.11.11.11/16 up This command will invoke the following netdev events in the following order: 1. NETDEV_UP 2. NETDEV_DOWN 3. NETDEV_UP If (2) and (3) will be executed concurrently or in reverse order, instead of having a new GID with 11.11.11.11 IP, we will end up without any new GIDs. Signed-off-by: Majd Dibbiny <majd@mellanox.com> Signed-off-by: Leon Romanovsky <leon@kernel.org> Reviewed-by: Yuval Shaia <yuval.shaia@oracle.com> Signed-off-by: Doug Ledford <dledford@redhat.com>
Diffstat (limited to 'drivers/infiniband')
-rw-r--r--drivers/infiniband/core/roce_gid_mgmt.c11
1 files changed, 9 insertions, 2 deletions
diff --git a/drivers/infiniband/core/roce_gid_mgmt.c b/drivers/infiniband/core/roce_gid_mgmt.c
index db958d3207ef..94a9eefb3cfc 100644
--- a/drivers/infiniband/core/roce_gid_mgmt.c
+++ b/drivers/infiniband/core/roce_gid_mgmt.c
@@ -42,6 +42,8 @@
#include <rdma/ib_cache.h>
#include <rdma/ib_addr.h>
+static struct workqueue_struct *gid_cache_wq;
+
enum gid_op_type {
GID_DEL = 0,
GID_ADD
@@ -560,7 +562,7 @@ static int netdevice_queue_work(struct netdev_event_work_cmd *cmds,
}
INIT_WORK(&ndev_work->work, netdevice_event_work_handler);
- queue_work(ib_wq, &ndev_work->work);
+ queue_work(gid_cache_wq, &ndev_work->work);
return NOTIFY_DONE;
}
@@ -693,7 +695,7 @@ static int addr_event(struct notifier_block *this, unsigned long event,
dev_hold(ndev);
work->gid_attr.ndev = ndev;
- queue_work(ib_wq, &work->work);
+ queue_work(gid_cache_wq, &work->work);
return NOTIFY_DONE;
}
@@ -740,6 +742,10 @@ static struct notifier_block nb_inet6addr = {
int __init roce_gid_mgmt_init(void)
{
+ gid_cache_wq = alloc_ordered_workqueue("gid-cache-wq", 0);
+ if (!gid_cache_wq)
+ return -ENOMEM;
+
register_inetaddr_notifier(&nb_inetaddr);
if (IS_ENABLED(CONFIG_IPV6))
register_inet6addr_notifier(&nb_inet6addr);
@@ -764,4 +770,5 @@ void __exit roce_gid_mgmt_cleanup(void)
* ib-core is removed, all physical devices have been removed,
* so no issue with remaining hardware contexts.
*/
+ destroy_workqueue(gid_cache_wq);
}