aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/bnx2x_link.c
diff options
context:
space:
mode:
authorYaniv Rosner <yanivr@broadcom.com>2009-11-05 19:18:12 +0200
committerDavid S. Miller <davem@davemloft.net>2009-11-05 20:00:35 -0800
commit15ddd2d0ef4849410a2251587b3652fe6a689fda (patch)
tree4964565c9e2f4bf350cc2774f29424c17028eac6 /drivers/net/bnx2x_link.c
parentbnx2x: Miscellaneous debug print and tabs (diff)
downloadlinux-dev-15ddd2d0ef4849410a2251587b3652fe6a689fda.tar.xz
linux-dev-15ddd2d0ef4849410a2251587b3652fe6a689fda.zip
bnx2x: Enable FC when parallel-detect is used
When parallel detect is used, flow-control is set to the req_fc_auto_adv instead of none. Motive: when 577xx is FC configuration is set to AUTO, while LP speed is set to FORCE mode and FC to force RX/TX, link would come up using parallel detect, and the FC will be set to NONE since FC capabilities were not negotiated, although the LP is setting FC to force RX/TX. Signed-off-by: Yaniv Rosner <yanivr@broadcom.com> Signed-off-by: Eilon Greenstein <eilong@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/bnx2x_link.c')
-rw-r--r--drivers/net/bnx2x_link.c37
1 files changed, 37 insertions, 0 deletions
diff --git a/drivers/net/bnx2x_link.c b/drivers/net/bnx2x_link.c
index bf1021ed5dd6..4c16a46f0caf 100644
--- a/drivers/net/bnx2x_link.c
+++ b/drivers/net/bnx2x_link.c
@@ -1621,6 +1621,39 @@ static u8 bnx2x_ext_phy_resolve_fc(struct link_params *params,
return ret;
}
+static u8 bnx2x_direct_parallel_detect_used(struct link_params *params)
+{
+ struct bnx2x *bp = params->bp;
+ u16 pd_10g, status2_1000x;
+ CL45_RD_OVER_CL22(bp, params->port,
+ params->phy_addr,
+ MDIO_REG_BANK_SERDES_DIGITAL,
+ MDIO_SERDES_DIGITAL_A_1000X_STATUS2,
+ &status2_1000x);
+ CL45_RD_OVER_CL22(bp, params->port,
+ params->phy_addr,
+ MDIO_REG_BANK_SERDES_DIGITAL,
+ MDIO_SERDES_DIGITAL_A_1000X_STATUS2,
+ &status2_1000x);
+ if (status2_1000x & MDIO_SERDES_DIGITAL_A_1000X_STATUS2_AN_DISABLED) {
+ DP(NETIF_MSG_LINK, "1G parallel detect link on port %d\n",
+ params->port);
+ return 1;
+ }
+
+ CL45_RD_OVER_CL22(bp, params->port,
+ params->phy_addr,
+ MDIO_REG_BANK_10G_PARALLEL_DETECT,
+ MDIO_10G_PARALLEL_DETECT_PAR_DET_10G_STATUS,
+ &pd_10g);
+
+ if (pd_10g & MDIO_10G_PARALLEL_DETECT_PAR_DET_10G_STATUS_PD_LINK) {
+ DP(NETIF_MSG_LINK, "10G parallel detect link on port %d\n",
+ params->port);
+ return 1;
+ }
+ return 0;
+}
static void bnx2x_flow_ctrl_resolve(struct link_params *params,
struct link_vars *vars,
@@ -1639,6 +1672,10 @@ static void bnx2x_flow_ctrl_resolve(struct link_params *params,
(!(vars->phy_flags & PHY_SGMII_FLAG)) &&
(XGXS_EXT_PHY_TYPE(params->ext_phy_config) ==
PORT_HW_CFG_XGXS_EXT_PHY_TYPE_DIRECT)) {
+ if (bnx2x_direct_parallel_detect_used(params)) {
+ vars->flow_ctrl = params->req_fc_auto_adv;
+ return;
+ }
if ((gp_status &
(MDIO_GP_STATUS_TOP_AN_STATUS1_CL73_AUTONEG_COMPLETE |
MDIO_GP_STATUS_TOP_AN_STATUS1_CL73_MR_LP_NP_AN_ABLE)) ==