aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/broadcom
diff options
context:
space:
mode:
authorMichael Chan <michael.chan@broadcom.com>2016-06-13 02:25:36 -0400
committerDavid S. Miller <davem@davemloft.net>2016-06-14 19:16:14 -0400
commitb24eb6ae7058ca1a42b0532489e5f5796c107d65 (patch)
tree20c82410b935b5b75e44463f3595d49248672387 /drivers/net/ethernet/broadcom
parentbnxt_en: Add GRO logic for BCM5731X chips. (diff)
downloadlinux-dev-b24eb6ae7058ca1a42b0532489e5f5796c107d65.tar.xz
linux-dev-b24eb6ae7058ca1a42b0532489e5f5796c107d65.zip
bnxt_en: Add BCM5731X and BCM5741X device IDs.
Signed-off-by: Michael Chan <michael.chan@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet/broadcom')
-rw-r--r--drivers/net/ethernet/broadcom/bnxt/bnxt.c30
1 files changed, 29 insertions, 1 deletions
diff --git a/drivers/net/ethernet/broadcom/bnxt/bnxt.c b/drivers/net/ethernet/broadcom/bnxt/bnxt.c
index 5f9285c2bad9..c2753296e75e 100644
--- a/drivers/net/ethernet/broadcom/bnxt/bnxt.c
+++ b/drivers/net/ethernet/broadcom/bnxt/bnxt.c
@@ -75,13 +75,22 @@ enum board_idx {
BCM57301,
BCM57302,
BCM57304,
+ BCM57311,
+ BCM57312,
BCM57402,
BCM57404,
BCM57406,
BCM57404_NPAR,
+ BCM57412,
+ BCM57414,
+ BCM57416,
+ BCM57417,
+ BCM57414_NPAR,
BCM57314,
BCM57304_VF,
BCM57404_VF,
+ BCM57414_VF,
+ BCM57314_VF,
};
/* indexed by enum above */
@@ -91,27 +100,45 @@ static const struct {
{ "Broadcom BCM57301 NetXtreme-C Single-port 10Gb Ethernet" },
{ "Broadcom BCM57302 NetXtreme-C Dual-port 10Gb/25Gb Ethernet" },
{ "Broadcom BCM57304 NetXtreme-C Dual-port 10Gb/25Gb/40Gb/50Gb Ethernet" },
+ { "Broadcom BCM57311 NetXtreme-C Single-port 10Gb Ethernet" },
+ { "Broadcom BCM57312 NetXtreme-C Dual-port 10Gb/25Gb Ethernet" },
{ "Broadcom BCM57402 NetXtreme-E Dual-port 10Gb Ethernet" },
{ "Broadcom BCM57404 NetXtreme-E Dual-port 10Gb/25Gb Ethernet" },
{ "Broadcom BCM57406 NetXtreme-E Dual-port 10GBase-T Ethernet" },
{ "Broadcom BCM57404 NetXtreme-E Ethernet Partition" },
+ { "Broadcom BCM57412 NetXtreme-E Dual-port 10Gb Ethernet" },
+ { "Broadcom BCM57414 NetXtreme-E Dual-port 10Gb/25Gb Ethernet" },
+ { "Broadcom BCM57416 NetXtreme-E Dual-port 10GBase-T Ethernet" },
+ { "Broadcom BCM57417 NetXtreme-E Dual-port 10GBase-T Ethernet" },
+ { "Broadcom BCM57414 NetXtreme-E Ethernet Partition" },
{ "Broadcom BCM57314 NetXtreme-C Dual-port 10Gb/25Gb/40Gb/50Gb Ethernet" },
{ "Broadcom BCM57304 NetXtreme-C Ethernet Virtual Function" },
{ "Broadcom BCM57404 NetXtreme-E Ethernet Virtual Function" },
+ { "Broadcom BCM57414 NetXtreme-E Ethernet Virtual Function" },
+ { "Broadcom BCM57314 NetXtreme-E Ethernet Virtual Function" },
};
static const struct pci_device_id bnxt_pci_tbl[] = {
{ PCI_VDEVICE(BROADCOM, 0x16c8), .driver_data = BCM57301 },
{ PCI_VDEVICE(BROADCOM, 0x16c9), .driver_data = BCM57302 },
{ PCI_VDEVICE(BROADCOM, 0x16ca), .driver_data = BCM57304 },
+ { PCI_VDEVICE(BROADCOM, 0x16ce), .driver_data = BCM57311 },
+ { PCI_VDEVICE(BROADCOM, 0x16cf), .driver_data = BCM57312 },
{ PCI_VDEVICE(BROADCOM, 0x16d0), .driver_data = BCM57402 },
{ PCI_VDEVICE(BROADCOM, 0x16d1), .driver_data = BCM57404 },
{ PCI_VDEVICE(BROADCOM, 0x16d2), .driver_data = BCM57406 },
{ PCI_VDEVICE(BROADCOM, 0x16d4), .driver_data = BCM57404_NPAR },
+ { PCI_VDEVICE(BROADCOM, 0x16d6), .driver_data = BCM57412 },
+ { PCI_VDEVICE(BROADCOM, 0x16d7), .driver_data = BCM57414 },
+ { PCI_VDEVICE(BROADCOM, 0x16d8), .driver_data = BCM57416 },
+ { PCI_VDEVICE(BROADCOM, 0x16d9), .driver_data = BCM57417 },
+ { PCI_VDEVICE(BROADCOM, 0x16de), .driver_data = BCM57414_NPAR },
{ PCI_VDEVICE(BROADCOM, 0x16df), .driver_data = BCM57314 },
#ifdef CONFIG_BNXT_SRIOV
{ PCI_VDEVICE(BROADCOM, 0x16cb), .driver_data = BCM57304_VF },
{ PCI_VDEVICE(BROADCOM, 0x16d3), .driver_data = BCM57404_VF },
+ { PCI_VDEVICE(BROADCOM, 0x16dc), .driver_data = BCM57414_VF },
+ { PCI_VDEVICE(BROADCOM, 0x16e1), .driver_data = BCM57314_VF },
#endif
{ 0 }
};
@@ -134,7 +161,8 @@ static const u16 bnxt_async_events_arr[] = {
static bool bnxt_vf_pciid(enum board_idx idx)
{
- return (idx == BCM57304_VF || idx == BCM57404_VF);
+ return (idx == BCM57304_VF || idx == BCM57404_VF ||
+ idx == BCM57314_VF || idx == BCM57414_VF);
}
#define DB_CP_REARM_FLAGS (DB_KEY_CP | DB_IDX_VALID)