diff options
author | David S. Miller <davem@davemloft.net> | 2019-08-08 18:44:31 -0700 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2019-08-08 18:44:31 -0700 |
commit | 2339ef1cf32744713ba56cd44ab75b0969fd79e1 (patch) | |
tree | b822e2d85a81320c74e07d2d8bf41455817dabae /drivers/net/ethernet | |
parent | Merge branch 'net-batched-receive-in-GRO-path' (diff) | |
parent | netfilter: nf_tables_offload: support indr block call (diff) | |
download | linux-dev-2339ef1cf32744713ba56cd44ab75b0969fd79e1.tar.xz linux-dev-2339ef1cf32744713ba56cd44ab75b0969fd79e1.zip |
Merge branch 'flow_offload-add-indr-block-in-nf_table_offload'
wenxu says:
====================
flow_offload: add indr-block in nf_table_offload
This series patch make nftables offload support the vlan and
tunnel device offload through indr-block architecture.
The first four patches mv tc indr block to flow offload and
rename to flow-indr-block.
Because the new flow-indr-block can't get the tcf_block
directly. The fifth patch provide a callback list to get
flow_block of each subsystem immediately when the device
register and contain a block.
The last patch make nf_tables_offload support flow-indr-block.
This version add a mutex lock for add/del flow_indr_block_ing_cb
====================
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet')
-rw-r--r-- | drivers/net/ethernet/mellanox/mlx5/core/en_rep.c | 10 | ||||
-rw-r--r-- | drivers/net/ethernet/netronome/nfp/flower/offload.c | 11 |
2 files changed, 11 insertions, 10 deletions
diff --git a/drivers/net/ethernet/mellanox/mlx5/core/en_rep.c b/drivers/net/ethernet/mellanox/mlx5/core/en_rep.c index fbb9de633578..b7f113e996e5 100644 --- a/drivers/net/ethernet/mellanox/mlx5/core/en_rep.c +++ b/drivers/net/ethernet/mellanox/mlx5/core/en_rep.c @@ -781,9 +781,9 @@ static int mlx5e_rep_indr_register_block(struct mlx5e_rep_priv *rpriv, { int err; - err = __tc_indr_block_cb_register(netdev, rpriv, - mlx5e_rep_indr_setup_tc_cb, - rpriv); + err = __flow_indr_block_cb_register(netdev, rpriv, + mlx5e_rep_indr_setup_tc_cb, + rpriv); if (err) { struct mlx5e_priv *priv = netdev_priv(rpriv->netdev); @@ -796,8 +796,8 @@ static int mlx5e_rep_indr_register_block(struct mlx5e_rep_priv *rpriv, static void mlx5e_rep_indr_unregister_block(struct mlx5e_rep_priv *rpriv, struct net_device *netdev) { - __tc_indr_block_cb_unregister(netdev, mlx5e_rep_indr_setup_tc_cb, - rpriv); + __flow_indr_block_cb_unregister(netdev, mlx5e_rep_indr_setup_tc_cb, + rpriv); } static int mlx5e_nic_rep_netdevice_event(struct notifier_block *nb, diff --git a/drivers/net/ethernet/netronome/nfp/flower/offload.c b/drivers/net/ethernet/netronome/nfp/flower/offload.c index ff8a9f1a38f8..3a4f4f042ae7 100644 --- a/drivers/net/ethernet/netronome/nfp/flower/offload.c +++ b/drivers/net/ethernet/netronome/nfp/flower/offload.c @@ -1649,16 +1649,17 @@ int nfp_flower_reg_indir_block_handler(struct nfp_app *app, return NOTIFY_OK; if (event == NETDEV_REGISTER) { - err = __tc_indr_block_cb_register(netdev, app, - nfp_flower_indr_setup_tc_cb, - app); + err = __flow_indr_block_cb_register(netdev, app, + nfp_flower_indr_setup_tc_cb, + app); if (err) nfp_flower_cmsg_warn(app, "Indirect block reg failed - %s\n", netdev->name); } else if (event == NETDEV_UNREGISTER) { - __tc_indr_block_cb_unregister(netdev, - nfp_flower_indr_setup_tc_cb, app); + __flow_indr_block_cb_unregister(netdev, + nfp_flower_indr_setup_tc_cb, + app); } return NOTIFY_OK; |