be2net: ignore get/set profile FW cmd failures
Old versions of BE3 FW may not support cmds to re-provision (and hence optimize) resources/queues in SR-IOV config. Do not treat this FW cmd failure as fatal and fail the function initialization. Instead, just enable SR-IOV with the resources provided by the FW. Prior to the "create optimal number of queues on SR-IOV config" patch such failures were ignored. Fixes: bec84e6b2 ("create optimal number of queues on SR-IOV config") Reported-by: Eduardo Habkost <ehabkost@redhat.com> Signed-off-by: Sathya Perla <sathya.perla@emulex.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net')
-rw-r--r--drivers/net/ethernet/emulex/benet/be_main.c67
1 files changed, 37 insertions, 30 deletions
diff --git a/drivers/net/ethernet/emulex/benet/be_main.c b/drivers/net/ethernet/emulex/benet/be_main.c
index 9c50814f1e95..da4d3863bd18 100644
--- a/drivers/net/ethernet/emulex/benet/be_main.c
+++ b/drivers/net/ethernet/emulex/benet/be_main.c
@@ -3342,22 +3342,17 @@ static int be_get_sriov_config(struct be_adapter *adapter)
{
struct device *dev = &adapter->pdev->dev;
struct be_resources res = {0};
- int status, max_vfs, old_vfs;
-
- status = be_cmd_get_profile_config(adapter, &res, 0);
- if (status)
- return status;
-
- adapter->pool_res = res;
+ int max_vfs, old_vfs;
/* Some old versions of BE3 FW don't report max_vfs value */
+ be_cmd_get_profile_config(adapter, &res, 0);
+
if (BE3_chip(adapter) && !res.max_vfs) {
max_vfs = pci_sriov_get_totalvfs(adapter->pdev);
res.max_vfs = max_vfs > 0 ? min(MAX_VFS, max_vfs) : 0;
}
- adapter->pool_res.max_vfs = res.max_vfs;
- pci_sriov_set_totalvfs(adapter->pdev, be_max_vfs(adapter));
+ adapter->pool_res = res;
if (!be_max_vfs(adapter)) {
if (num_vfs)
@@ -3366,6 +3361,8 @@ static int be_get_sriov_config(struct be_adapter *adapter)
return 0;
}
+ pci_sriov_set_totalvfs(adapter->pdev, be_max_vfs(adapter));
+
/* validate num_vfs module param */
old_vfs = pci_num_vf(adapter->pdev);
if (old_vfs) {
@@ -3423,6 +3420,35 @@ static int be_get_resources(struct be_adapter *adapter)
return 0;
}
+static void be_sriov_config(struct be_adapter *adapter)
+{
+ struct device *dev = &adapter->pdev->dev;
+ int status;
+
+ status = be_get_sriov_config(adapter);
+ if (status) {
+ dev_err(dev, "Failed to query SR-IOV configuration\n");
+ dev_err(dev, "SR-IOV cannot be enabled\n");
+ return;
+ }
+
+ /* When the HW is in SRIOV capable configuration, the PF-pool
+ * resources are equally distributed across the max-number of
+ * VFs. The user may request only a subset of the max-vfs to be
+ * enabled. Based on num_vfs, redistribute the resources across
+ * num_vfs so that each VF will have access to more number of
+ * resources. This facility is not available in BE3 FW.
+ * Also, this is done by FW in Lancer chip.
+ */
+ if (be_max_vfs(adapter) && !pci_num_vf(adapter->pdev)) {
+ status = be_cmd_set_sriov_config(adapter,
+ adapter->pool_res,
+ adapter->num_vfs);
+ if (status)
+ dev_err(dev, "Failed to optimize SR-IOV resources\n");
+ }
+}
+
static int be_get_config(struct be_adapter *adapter)
{
u16 profile_id;
@@ -3439,27 +3465,8 @@ static int be_get_config(struct be_adapter *adapter)
"Using profile 0x%x\n", profile_id);
}
- if (!BE2_chip(adapter) && be_physfn(adapter)) {
- status = be_get_sriov_config(adapter);
- if (status)
- return status;
-
- /* When the HW is in SRIOV capable configuration, the PF-pool
- * resources are equally distributed across the max-number of
- * VFs. The user may request only a subset of the max-vfs to be
- * enabled. Based on num_vfs, redistribute the resources across
- * num_vfs so that each VF will have access to more number of
- * resources. This facility is not available in BE3 FW.
- * Also, this is done by FW in Lancer chip.
- */
- if (!pci_num_vf(adapter->pdev)) {
- status = be_cmd_set_sriov_config(adapter,
- adapter->pool_res,
- adapter->num_vfs);
- if (status)
- return status;
- }
- }
+ if (!BE2_chip(adapter) && be_physfn(adapter))
+ be_sriov_config(adapter);
status = be_get_resources(adapter);
if (status)