aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/platform/x86
diff options
context:
space:
mode:
authorJan Kiszka <jan.kiszka@siemens.com>2019-09-04 08:42:30 +0200
committerAndy Shevchenko <andriy.shevchenko@linux.intel.com>2019-09-07 21:16:09 +0300
commitad0d315b4d4e7138f43acf03308192ec00e9614d (patch)
tree0393bc838290e7f081cfe8f525ca6ebca4dc793b /drivers/platform/x86
parentplatform/x86: intel_pmc_core_pltdrv: Module removal warning fix (diff)
downloadlinux-dev-ad0d315b4d4e7138f43acf03308192ec00e9614d.tar.xz
linux-dev-ad0d315b4d4e7138f43acf03308192ec00e9614d.zip
platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table
The SIMATIC IPC227E uses the PMC clock for on-board components and gets stuck during boot if the clock is disabled. Therefore, add this device to the critical systems list. Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Diffstat (limited to 'drivers/platform/x86')
-rw-r--r--drivers/platform/x86/pmc_atom.c7
1 files changed, 7 insertions, 0 deletions
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index aa53648a2214..9aca5e7ce6d0 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -415,6 +415,13 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
},
},
+ {
+ .ident = "SIMATIC IPC227E",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+ DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
+ },
+ },
{ /*sentinel*/ }
};