aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/power
diff options
context:
space:
mode:
authorYuanjiang Yu <yuanjiang.yu@unisoc.com>2019-07-31 18:00:26 +0800
committerSebastian Reichel <sre@kernel.org>2019-09-02 22:59:50 +0200
commit580665279fb6a16eb119ec80a5be1b3ec7a641a0 (patch)
treebe9a721e6da270f8237e336c612a4998a74b658e /drivers/power
parentpower: supply: sc27xx: Make sure the alarm capacity is larger than 0 (diff)
downloadlinux-dev-580665279fb6a16eb119ec80a5be1b3ec7a641a0.tar.xz
linux-dev-580665279fb6a16eb119ec80a5be1b3ec7a641a0.zip
power: supply: sc27xx: Optimize the battery capacity calibration
This patch factors out the capacity calibration into one single function to calibrate the battery capacity, and adding more abnormal cases to calibrate the capacity when the OCV value is not matchable with current capacity. Moreover we also allow to calibrate the capacity when charger magager tries to get current capacity to make sure we give a correct capacity for userspace. Signed-off-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com> Signed-off-by: Baolin Wang <baolin.wang@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/supply/sc27xx_fuel_gauge.c127
1 files changed, 92 insertions, 35 deletions
diff --git a/drivers/power/supply/sc27xx_fuel_gauge.c b/drivers/power/supply/sc27xx_fuel_gauge.c
index 096da951f465..6071671caaa9 100644
--- a/drivers/power/supply/sc27xx_fuel_gauge.c
+++ b/drivers/power/supply/sc27xx_fuel_gauge.c
@@ -109,6 +109,8 @@ struct sc27xx_fgu_data {
};
static int sc27xx_fgu_cap_to_clbcnt(struct sc27xx_fgu_data *data, int capacity);
+static void sc27xx_fgu_capacity_calibration(struct sc27xx_fgu_data *data,
+ int cap, bool int_mode);
static const char * const sc27xx_charger_supply_name[] = {
"sc2731_charger",
@@ -389,6 +391,9 @@ static int sc27xx_fgu_get_capacity(struct sc27xx_fgu_data *data, int *cap)
delta_cap = DIV_ROUND_CLOSEST(temp * 100, data->total_cap);
*cap = delta_cap + data->init_cap;
+ /* Calibrate the battery capacity in a normal range. */
+ sc27xx_fgu_capacity_calibration(data, *cap, false);
+
return 0;
}
@@ -661,50 +666,62 @@ static const struct power_supply_desc sc27xx_fgu_desc = {
static void sc27xx_fgu_adjust_cap(struct sc27xx_fgu_data *data, int cap)
{
+ int ret;
+
data->init_cap = cap;
- data->init_clbcnt = sc27xx_fgu_cap_to_clbcnt(data, data->init_cap);
+ ret = sc27xx_fgu_get_clbcnt(data, &data->init_clbcnt);
+ if (ret)
+ dev_err(data->dev, "failed to get init coulomb counter\n");
}
-static irqreturn_t sc27xx_fgu_interrupt(int irq, void *dev_id)
+static void sc27xx_fgu_capacity_calibration(struct sc27xx_fgu_data *data,
+ int cap, bool int_mode)
{
- struct sc27xx_fgu_data *data = dev_id;
- int ret, cap, ocv, adc;
- u32 status;
-
- mutex_lock(&data->lock);
+ int ret, ocv, chg_sts, adc;
- ret = regmap_read(data->regmap, data->base + SC27XX_FGU_INT_STS,
- &status);
- if (ret)
- goto out;
+ ret = sc27xx_fgu_get_vbat_ocv(data, &ocv);
+ if (ret) {
+ dev_err(data->dev, "get battery ocv error.\n");
+ return;
+ }
- ret = regmap_update_bits(data->regmap, data->base + SC27XX_FGU_INT_CLR,
- status, status);
- if (ret)
- goto out;
+ ret = sc27xx_fgu_get_status(data, &chg_sts);
+ if (ret) {
+ dev_err(data->dev, "get charger status error.\n");
+ return;
+ }
/*
- * When low overload voltage interrupt happens, we should calibrate the
- * battery capacity in lower voltage stage.
+ * If we are in charging mode, then we do not need to calibrate the
+ * lower capacity.
*/
- if (!(status & SC27XX_FGU_LOW_OVERLOAD_INT))
- goto out;
+ if (chg_sts == POWER_SUPPLY_STATUS_CHARGING)
+ return;
- ret = sc27xx_fgu_get_capacity(data, &cap);
- if (ret)
- goto out;
-
- ret = sc27xx_fgu_get_vbat_ocv(data, &ocv);
- if (ret)
- goto out;
-
- /*
- * If current OCV value is less than the minimum OCV value in OCV table,
- * which means now battery capacity is 0%, and we should adjust the
- * inititial capacity to 0.
- */
- if (ocv <= data->cap_table[data->table_len - 1].ocv) {
+ if ((ocv > data->cap_table[0].ocv && cap < 100) || cap > 100) {
+ /*
+ * If current OCV value is larger than the max OCV value in
+ * OCV table, or the current capacity is larger than 100,
+ * we should force the inititial capacity to 100.
+ */
+ sc27xx_fgu_adjust_cap(data, 100);
+ } else if (ocv <= data->cap_table[data->table_len - 1].ocv) {
+ /*
+ * If current OCV value is leass than the minimum OCV value in
+ * OCV table, we should force the inititial capacity to 0.
+ */
sc27xx_fgu_adjust_cap(data, 0);
+ } else if ((ocv > data->cap_table[data->table_len - 1].ocv && cap <= 0) ||
+ (ocv > data->min_volt && cap <= data->alarm_cap)) {
+ /*
+ * If current OCV value is not matchable with current capacity,
+ * we should re-calculate current capacity by looking up the
+ * OCV table.
+ */
+ int cur_cap = power_supply_ocv2cap_simple(data->cap_table,
+ data->table_len, ocv);
+
+ sc27xx_fgu_adjust_cap(data, cur_cap);
} else if (ocv <= data->min_volt) {
/*
* If current OCV value is less than the low alarm voltage, but
@@ -713,7 +730,7 @@ static irqreturn_t sc27xx_fgu_interrupt(int irq, void *dev_id)
*/
if (cap > data->alarm_cap) {
sc27xx_fgu_adjust_cap(data, data->alarm_cap);
- } else if (cap <= 0) {
+ } else {
int cur_cap;
/*
@@ -728,15 +745,55 @@ static irqreturn_t sc27xx_fgu_interrupt(int irq, void *dev_id)
sc27xx_fgu_adjust_cap(data, cur_cap);
}
+ if (!int_mode)
+ return;
+
/*
* After adjusting the battery capacity, we should set the
* lowest alarm voltage instead.
*/
data->min_volt = data->cap_table[data->table_len - 1].ocv;
+ data->alarm_cap = power_supply_ocv2cap_simple(data->cap_table,
+ data->table_len,
+ data->min_volt);
+
adc = sc27xx_fgu_voltage_to_adc(data, data->min_volt / 1000);
- regmap_update_bits(data->regmap, data->base + SC27XX_FGU_LOW_OVERLOAD,
+ regmap_update_bits(data->regmap,
+ data->base + SC27XX_FGU_LOW_OVERLOAD,
SC27XX_FGU_LOW_OVERLOAD_MASK, adc);
}
+}
+
+static irqreturn_t sc27xx_fgu_interrupt(int irq, void *dev_id)
+{
+ struct sc27xx_fgu_data *data = dev_id;
+ int ret, cap;
+ u32 status;
+
+ mutex_lock(&data->lock);
+
+ ret = regmap_read(data->regmap, data->base + SC27XX_FGU_INT_STS,
+ &status);
+ if (ret)
+ goto out;
+
+ ret = regmap_update_bits(data->regmap, data->base + SC27XX_FGU_INT_CLR,
+ status, status);
+ if (ret)
+ goto out;
+
+ /*
+ * When low overload voltage interrupt happens, we should calibrate the
+ * battery capacity in lower voltage stage.
+ */
+ if (!(status & SC27XX_FGU_LOW_OVERLOAD_INT))
+ goto out;
+
+ ret = sc27xx_fgu_get_capacity(data, &cap);
+ if (ret)
+ goto out;
+
+ sc27xx_fgu_capacity_calibration(data, cap, true);
out:
mutex_unlock(&data->lock);