authorPavel Machek <pavel@ucw.cz>2014-10-29 14:50:42 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2014-10-29 16:33:14 -0700
commit5a6e7599d3f8000496068b12276492311efad5ea (patch)
treefcc773f9e12207ae748d26d10ae661f2ba0f6564 /drivers/rtc
parentmemory-hotplug: clear pgdat which is allocated by bootmem in try_offline_node() (diff)
downloadlinux-dev-5a6e7599d3f8000496068b12276492311efad5ea.tar.xz
linux-dev-5a6e7599d3f8000496068b12276492311efad5ea.zip
drivers/rtc/rtc-bq32k.c: fix register value
Fix register value in bq32000 trickle charging. Mike reported that I'm using wrong value in one trickle-charging case, and after checking docs, I must admit he's right. Signed-off-by: Pavel Machek <pavel@denx.de> Reported-by: Mike Bremford <mike@bfo.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'drivers/rtc')
-rw-r--r--drivers/rtc/rtc-bq32k.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/rtc/rtc-bq32k.c b/drivers/rtc/rtc-bq32k.c
index 314129e66d6e..92679df6d6e2 100644
--- a/drivers/rtc/rtc-bq32k.c
+++ b/drivers/rtc/rtc-bq32k.c
@@ -160,7 +160,7 @@ static int trickle_charger_of_init(struct device *dev, struct device_node *node)
dev_err(dev, "bq32k: diode and resistor mismatch\n");
return -EINVAL;
}
- reg = 0x25;
+ reg = 0x45;
break;
default: