aboutsummaryrefslogtreecommitdiffstats
path: root/drivers/scsi/storvsc_drv.c
diff options
context:
space:
mode:
authorK. Y. Srinivasan <kys@microsoft.com>2016-01-27 18:22:44 -0800
committerMartin K. Petersen <martin.petersen@oracle.com>2016-01-28 22:25:36 -0500
commitd791a8c60e9cbd1c4fecbc5c86ff59c7ffe137e8 (patch)
treeab2180748dc7b685aff22c0816e35631ac5f4106 /drivers/scsi/storvsc_drv.c
parenthisi_sas: fix v1 hw check for slot error (diff)
downloadlinux-dev-d791a8c60e9cbd1c4fecbc5c86ff59c7ffe137e8.tar.xz
linux-dev-d791a8c60e9cbd1c4fecbc5c86ff59c7ffe137e8.zip
storvsc: Install the storvsc specific timeout handler for FC devices
The default timeout routine used for FC transport is not suitable for FC devices managed by storvsc since FC devices managed by storvsc driver do not have an rport associated with them. Use the time out handler used for SCSI devices for FC devices as well. Signed-off-by: K. Y. Srinivasan <kys@microsoft.com> Reviewed-by: Alex Ng <alexng@microsoft.com> Tested-by: Vivek Yadav <vyadav@microsoft.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi/storvsc_drv.c')
-rw-r--r--drivers/scsi/storvsc_drv.c6
1 files changed, 6 insertions, 0 deletions
diff --git a/drivers/scsi/storvsc_drv.c b/drivers/scsi/storvsc_drv.c
index 41c115c230d9..622f64a98a9e 100644
--- a/drivers/scsi/storvsc_drv.c
+++ b/drivers/scsi/storvsc_drv.c
@@ -42,6 +42,7 @@
#include <scsi/scsi_devinfo.h>
#include <scsi/scsi_dbg.h>
#include <scsi/scsi_transport_fc.h>
+#include <scsi/scsi_transport.h>
/*
* All wire protocol details (storage protocol between the guest and the host)
@@ -1770,6 +1771,11 @@ static int __init storvsc_drv_init(void)
fc_transport_template = fc_attach_transport(&fc_transport_functions);
if (!fc_transport_template)
return -ENODEV;
+
+ /*
+ * Install Hyper-V specific timeout handler.
+ */
+ fc_transport_template->eh_timed_out = storvsc_eh_timed_out;
#endif
ret = vmbus_driver_register(&storvsc_drv);