authorCrt Mori <cmo@melexis.com>2019-05-23 14:07:22 +0200
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2019-05-27 10:52:30 +0100
commit389fc70b60f534d679aea9a3f05146040ce20d77 (patch)
treec2206a09fd6106beb7edec256b24d3b6a76440c6 /drivers/staging/iio
parentiio: imu: st_lsm6dsx: fix PM support for st_lsm6dsx i2c controller (diff)
downloadlinux-dev-389fc70b60f534d679aea9a3f05146040ce20d77.tar.xz
linux-dev-389fc70b60f534d679aea9a3f05146040ce20d77.zip
iio: temperature: mlx90632 Relax the compatibility check
Register EE_VERSION contains mixture of calibration information and DSP version. So far, because calibrations were definite, the driver compatibility depended on whole contents, but in the newer production process the calibration part changes. Because of that, value in EE_VERSION will be changed and to avoid that calibration value is same as DSP version the MSB in calibration part was fixed to 1. That means existing calibrations (medical and consumer) will now have hex values (bits 8 to 15) of 83 and 84 respectively. Driver compatibility should be based only on DSP version part of the EE_VERSION (bits 0 to 7) register. Signed-off-by: Crt Mori <cmo@melexis.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'drivers/staging/iio')
0 files changed, 0 insertions, 0 deletions