thermal: power allocator: change the 'k_*' always in estimate_pid_constants()
The PID coefficients should be estimated again when there was a change to sustainable power value made by user. This change removes unused argument 'force' and makes the function ready for such updates. Signed-off-by: Lukasz Luba <lukasz.luba@arm.com> Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20201124161025.27694-4-lukasz.luba@arm.com
Diffstat (limited to 'drivers/thermal/gov_power_allocator.c')
-rw-r--r--drivers/thermal/gov_power_allocator.c28
1 files changed, 9 insertions, 19 deletions
diff --git a/drivers/thermal/gov_power_allocator.c b/drivers/thermal/gov_power_allocator.c
index d7e4b9f6af60..7a4170a0b51f 100644
--- a/drivers/thermal/gov_power_allocator.c
+++ b/drivers/thermal/gov_power_allocator.c
@@ -117,18 +117,13 @@ static u32 estimate_sustainable_power(struct thermal_zone_device *tz)
* @sustainable_power: sustainable power for the thermal zone
* @trip_switch_on: trip point number for the switch on temperature
* @control_temp: target temperature for the power allocator governor
- * @force: whether to force the update of the constants
*
* This function is used to update the estimation of the PID
* controller constants in struct thermal_zone_parameters.
- *
- * If @force is not set, the values in the thermal zone's parameters
- * are preserved if they are not zero. If @force is set, the values
- * in thermal zone's parameters are overwritten.
*/
static void estimate_pid_constants(struct thermal_zone_device *tz,
u32 sustainable_power, int trip_switch_on,
- int control_temp, bool force)
+ int control_temp)
{
int ret;
int switch_on_temp;
@@ -151,18 +146,14 @@ static void estimate_pid_constants(struct thermal_zone_device *tz,
if (!temperature_threshold)
return;
- if (!tz->tzp->k_po || force)
- tz->tzp->k_po = int_to_frac(sustainable_power) /
- temperature_threshold;
+ tz->tzp->k_po = int_to_frac(sustainable_power) /
+ temperature_threshold;
- if (!tz->tzp->k_pu || force)
- tz->tzp->k_pu = int_to_frac(2 * sustainable_power) /
- temperature_threshold;
+ tz->tzp->k_pu = int_to_frac(2 * sustainable_power) /
+ temperature_threshold;
- if (!tz->tzp->k_i || force) {
- k_i = tz->tzp->k_pu / 10;
- tz->tzp->k_i = k_i > 0 ? k_i : 1;
- }
+ k_i = tz->tzp->k_pu / 10;
+ tz->tzp->k_i = k_i > 0 ? k_i : 1;
/*
* The default for k_d and integral_cutoff is 0, so we can
@@ -195,8 +186,7 @@ static u32 get_sustainable_power(struct thermal_zone_device *tz,
/* Check if it's init value 0 or there was update via sysfs */
if (sustainable_power != params->sustainable_power) {
estimate_pid_constants(tz, sustainable_power,
- params->trip_switch_on, control_temp,
- true);
+ params->trip_switch_on, control_temp);
/* Do the estimation only once and make available in sysfs */
tz->tzp->sustainable_power = sustainable_power;
@@ -640,7 +630,7 @@ static int power_allocator_bind(struct thermal_zone_device *tz)
if (!ret)
estimate_pid_constants(tz, tz->tzp->sustainable_power,
params->trip_switch_on,
- control_temp, false);
+ control_temp);
}
reset_pid_controller(params);