regulator: bd71837: Disable voltage monitoring for LDO3/4
There is a HW quirk in BD71837. The shutdown sequence timings for bucks/LDOs which are enabled via register interface are changed. At PMIC poweroff the voltage for BUCK6/7 is cut immediately at the beginning of shut-down sequence. This causes LDO5/6 voltage monitoring to detect under voltage and force PMIC to emergency state instead of poweroff. Disable voltage monitoring for LDO5 and LDO6 at probe to avoid this. Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Mark Brown <broonie@kernel.org> Cc: stable@vger.kernel.org
Diffstat (limited to 'include')
-rw-r--r--include/linux/mfd/rohm-bd718x7.h33
1 files changed, 30 insertions, 3 deletions
diff --git a/include/linux/mfd/rohm-bd718x7.h b/include/linux/mfd/rohm-bd718x7.h
index a528747f8aed..e8338e5dc10b 100644
--- a/include/linux/mfd/rohm-bd718x7.h
+++ b/include/linux/mfd/rohm-bd718x7.h
@@ -78,9 +78,9 @@ enum {
BD71837_REG_TRANS_COND0 = 0x1F,
BD71837_REG_TRANS_COND1 = 0x20,
BD71837_REG_VRFAULTEN = 0x21,
- BD71837_REG_MVRFLTMASK0 = 0x22,
- BD71837_REG_MVRFLTMASK1 = 0x23,
- BD71837_REG_MVRFLTMASK2 = 0x24,
+ BD718XX_REG_MVRFLTMASK0 = 0x22,
+ BD718XX_REG_MVRFLTMASK1 = 0x23,
+ BD718XX_REG_MVRFLTMASK2 = 0x24,
BD71837_REG_RCVCFG = 0x25,
BD71837_REG_RCVNUM = 0x26,
BD71837_REG_PWRONCONFIG0 = 0x27,
@@ -159,6 +159,33 @@ enum {
#define BUCK8_MASK 0x3F
#define BUCK8_DEFAULT 0x1E
+/* BD718XX Voltage monitoring masks */
+#define BD718XX_BUCK1_VRMON80 0x1
+#define BD718XX_BUCK1_VRMON130 0x2
+#define BD718XX_BUCK2_VRMON80 0x4
+#define BD718XX_BUCK2_VRMON130 0x8
+#define BD718XX_1ST_NODVS_BUCK_VRMON80 0x1
+#define BD718XX_1ST_NODVS_BUCK_VRMON130 0x2
+#define BD718XX_2ND_NODVS_BUCK_VRMON80 0x4
+#define BD718XX_2ND_NODVS_BUCK_VRMON130 0x8
+#define BD718XX_3RD_NODVS_BUCK_VRMON80 0x10
+#define BD718XX_3RD_NODVS_BUCK_VRMON130 0x20
+#define BD718XX_4TH_NODVS_BUCK_VRMON80 0x40
+#define BD718XX_4TH_NODVS_BUCK_VRMON130 0x80
+#define BD718XX_LDO1_VRMON80 0x1
+#define BD718XX_LDO2_VRMON80 0x2
+#define BD718XX_LDO3_VRMON80 0x4
+#define BD718XX_LDO4_VRMON80 0x8
+#define BD718XX_LDO5_VRMON80 0x10
+#define BD718XX_LDO6_VRMON80 0x20
+
+/* BD71837 specific voltage monitoring masks */
+#define BD71837_BUCK3_VRMON80 0x10
+#define BD71837_BUCK3_VRMON130 0x20
+#define BD71837_BUCK4_VRMON80 0x40
+#define BD71837_BUCK4_VRMON130 0x80
+#define BD71837_LDO7_VRMON80 0x40
+
/* BD71837_REG_IRQ bits */
#define IRQ_SWRST 0x40
#define IRQ_PWRON_S 0x20