aboutsummaryrefslogtreecommitdiffstats
path: root/net/ipv4
diff options
context:
space:
mode:
authorDavid Ahern <dsahern@gmail.com>2019-04-05 16:30:31 -0700
committerDavid S. Miller <davem@davemloft.net>2019-04-08 15:22:41 -0700
commit448d7248191706cbbd7761e3bc72c2985c4d38a7 (patch)
tree30cf5625d5b433cce8f8b1bca1369249a2c9954b /net/ipv4
parentipv4: Add support to fib_config for IPv6 gateway (diff)
downloadlinux-dev-448d7248191706cbbd7761e3bc72c2985c4d38a7.tar.xz
linux-dev-448d7248191706cbbd7761e3bc72c2985c4d38a7.zip
ipv4: Refactor fib_check_nh
fib_check_nh is currently huge covering multiple uses cases - device only, device + gateway, and device + gateway with ONLINK. The next patch adds validation checks for IPv6 which only further complicates it. So, break fib_check_nh into 2 helpers - one for gateway validation and one for device only. Signed-off-by: David Ahern <dsahern@gmail.com> Reviewed-by: Ido Schimmel <idosch@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'net/ipv4')
-rw-r--r--net/ipv4/fib_semantics.c234
1 files changed, 125 insertions, 109 deletions
diff --git a/net/ipv4/fib_semantics.c b/net/ipv4/fib_semantics.c
index 680b5a9a911a..32ce6e6202d2 100644
--- a/net/ipv4/fib_semantics.c
+++ b/net/ipv4/fib_semantics.c
@@ -885,134 +885,150 @@ bool fib_metrics_match(struct fib_config *cfg, struct fib_info *fi)
* |
* |-> {local prefix} (terminal node)
*/
-static int fib_check_nh(struct fib_config *cfg, struct fib_nh *nh,
- struct netlink_ext_ack *extack)
+static int fib_check_nh_v4_gw(struct net *net, struct fib_nh *nh, u32 table,
+ u8 scope, struct netlink_ext_ack *extack)
{
- int err = 0;
- struct net *net;
struct net_device *dev;
+ struct fib_result res;
+ int err;
- net = cfg->fc_nlinfo.nl_net;
- if (nh->fib_nh_gw4) {
- struct fib_result res;
-
- if (nh->fib_nh_flags & RTNH_F_ONLINK) {
- unsigned int addr_type;
+ if (nh->fib_nh_flags & RTNH_F_ONLINK) {
+ unsigned int addr_type;
- if (cfg->fc_scope >= RT_SCOPE_LINK) {
- NL_SET_ERR_MSG(extack,
- "Nexthop has invalid scope");
- return -EINVAL;
- }
- dev = __dev_get_by_index(net, nh->fib_nh_oif);
- if (!dev) {
- NL_SET_ERR_MSG(extack, "Nexthop device required for onlink");
- return -ENODEV;
- }
- if (!(dev->flags & IFF_UP)) {
- NL_SET_ERR_MSG(extack,
- "Nexthop device is not up");
- return -ENETDOWN;
- }
- addr_type = inet_addr_type_dev_table(net, dev,
- nh->fib_nh_gw4);
- if (addr_type != RTN_UNICAST) {
- NL_SET_ERR_MSG(extack,
- "Nexthop has invalid gateway");
- return -EINVAL;
- }
- if (!netif_carrier_ok(dev))
- nh->fib_nh_flags |= RTNH_F_LINKDOWN;
- nh->fib_nh_dev = dev;
- dev_hold(dev);
- nh->fib_nh_scope = RT_SCOPE_LINK;
- return 0;
+ if (scope >= RT_SCOPE_LINK) {
+ NL_SET_ERR_MSG(extack, "Nexthop has invalid scope");
+ return -EINVAL;
}
- rcu_read_lock();
- {
- struct fib_table *tbl = NULL;
- struct flowi4 fl4 = {
- .daddr = nh->fib_nh_gw4,
- .flowi4_scope = cfg->fc_scope + 1,
- .flowi4_oif = nh->fib_nh_oif,
- .flowi4_iif = LOOPBACK_IFINDEX,
- };
-
- /* It is not necessary, but requires a bit of thinking */
- if (fl4.flowi4_scope < RT_SCOPE_LINK)
- fl4.flowi4_scope = RT_SCOPE_LINK;
-
- if (cfg->fc_table)
- tbl = fib_get_table(net, cfg->fc_table);
-
- if (tbl)
- err = fib_table_lookup(tbl, &fl4, &res,
- FIB_LOOKUP_IGNORE_LINKSTATE |
- FIB_LOOKUP_NOREF);
-
- /* on error or if no table given do full lookup. This
- * is needed for example when nexthops are in the local
- * table rather than the given table
- */
- if (!tbl || err) {
- err = fib_lookup(net, &fl4, &res,
- FIB_LOOKUP_IGNORE_LINKSTATE);
- }
-
- if (err) {
- NL_SET_ERR_MSG(extack,
- "Nexthop has invalid gateway");
- rcu_read_unlock();
- return err;
- }
+ dev = __dev_get_by_index(net, nh->fib_nh_oif);
+ if (!dev) {
+ NL_SET_ERR_MSG(extack, "Nexthop device required for onlink");
+ return -ENODEV;
}
- err = -EINVAL;
- if (res.type != RTN_UNICAST && res.type != RTN_LOCAL) {
- NL_SET_ERR_MSG(extack, "Nexthop has invalid gateway");
- goto out;
+ if (!(dev->flags & IFF_UP)) {
+ NL_SET_ERR_MSG(extack, "Nexthop device is not up");
+ return -ENETDOWN;
}
- nh->fib_nh_scope = res.scope;
- nh->fib_nh_oif = FIB_RES_OIF(res);
- nh->fib_nh_dev = dev = FIB_RES_DEV(res);
- if (!dev) {
- NL_SET_ERR_MSG(extack,
- "No egress device for nexthop gateway");
- goto out;
+ addr_type = inet_addr_type_dev_table(net, dev, nh->fib_nh_gw4);
+ if (addr_type != RTN_UNICAST) {
+ NL_SET_ERR_MSG(extack, "Nexthop has invalid gateway");
+ return -EINVAL;
}
- dev_hold(dev);
if (!netif_carrier_ok(dev))
nh->fib_nh_flags |= RTNH_F_LINKDOWN;
- err = (dev->flags & IFF_UP) ? 0 : -ENETDOWN;
- } else {
- struct in_device *in_dev;
-
- if (nh->fib_nh_flags & (RTNH_F_PERVASIVE | RTNH_F_ONLINK)) {
- NL_SET_ERR_MSG(extack,
- "Invalid flags for nexthop - PERVASIVE and ONLINK can not be set");
- return -EINVAL;
+ nh->fib_nh_dev = dev;
+ dev_hold(dev);
+ nh->fib_nh_scope = RT_SCOPE_LINK;
+ return 0;
+ }
+ rcu_read_lock();
+ {
+ struct fib_table *tbl = NULL;
+ struct flowi4 fl4 = {
+ .daddr = nh->fib_nh_gw4,
+ .flowi4_scope = scope + 1,
+ .flowi4_oif = nh->fib_nh_oif,
+ .flowi4_iif = LOOPBACK_IFINDEX,
+ };
+
+ /* It is not necessary, but requires a bit of thinking */
+ if (fl4.flowi4_scope < RT_SCOPE_LINK)
+ fl4.flowi4_scope = RT_SCOPE_LINK;
+
+ if (table)
+ tbl = fib_get_table(net, table);
+
+ if (tbl)
+ err = fib_table_lookup(tbl, &fl4, &res,
+ FIB_LOOKUP_IGNORE_LINKSTATE |
+ FIB_LOOKUP_NOREF);
+
+ /* on error or if no table given do full lookup. This
+ * is needed for example when nexthops are in the local
+ * table rather than the given table
+ */
+ if (!tbl || err) {
+ err = fib_lookup(net, &fl4, &res,
+ FIB_LOOKUP_IGNORE_LINKSTATE);
}
- rcu_read_lock();
- err = -ENODEV;
- in_dev = inetdev_by_index(net, nh->fib_nh_oif);
- if (!in_dev)
- goto out;
- err = -ENETDOWN;
- if (!(in_dev->dev->flags & IFF_UP)) {
- NL_SET_ERR_MSG(extack, "Device for nexthop is not up");
+
+ if (err) {
+ NL_SET_ERR_MSG(extack, "Nexthop has invalid gateway");
goto out;
}
- nh->fib_nh_dev = in_dev->dev;
- dev_hold(nh->fib_nh_dev);
- nh->fib_nh_scope = RT_SCOPE_HOST;
- if (!netif_carrier_ok(nh->fib_nh_dev))
- nh->fib_nh_flags |= RTNH_F_LINKDOWN;
- err = 0;
}
+
+ err = -EINVAL;
+ if (res.type != RTN_UNICAST && res.type != RTN_LOCAL) {
+ NL_SET_ERR_MSG(extack, "Nexthop has invalid gateway");
+ goto out;
+ }
+ nh->fib_nh_scope = res.scope;
+ nh->fib_nh_oif = FIB_RES_OIF(res);
+ nh->fib_nh_dev = dev = FIB_RES_DEV(res);
+ if (!dev) {
+ NL_SET_ERR_MSG(extack,
+ "No egress device for nexthop gateway");
+ goto out;
+ }
+ dev_hold(dev);
+ if (!netif_carrier_ok(dev))
+ nh->fib_nh_flags |= RTNH_F_LINKDOWN;
+ err = (dev->flags & IFF_UP) ? 0 : -ENETDOWN;
out:
rcu_read_unlock();
return err;
}
+static int fib_check_nh_nongw(struct net *net, struct fib_nh *nh,
+ struct netlink_ext_ack *extack)
+{
+ struct in_device *in_dev;
+ int err;
+
+ if (nh->fib_nh_flags & (RTNH_F_PERVASIVE | RTNH_F_ONLINK)) {
+ NL_SET_ERR_MSG(extack,
+ "Invalid flags for nexthop - PERVASIVE and ONLINK can not be set");
+ return -EINVAL;
+ }
+
+ rcu_read_lock();
+
+ err = -ENODEV;
+ in_dev = inetdev_by_index(net, nh->fib_nh_oif);
+ if (!in_dev)
+ goto out;
+ err = -ENETDOWN;
+ if (!(in_dev->dev->flags & IFF_UP)) {
+ NL_SET_ERR_MSG(extack, "Device for nexthop is not up");
+ goto out;
+ }
+
+ nh->fib_nh_dev = in_dev->dev;
+ dev_hold(nh->fib_nh_dev);
+ nh->fib_nh_scope = RT_SCOPE_HOST;
+ if (!netif_carrier_ok(nh->fib_nh_dev))
+ nh->fib_nh_flags |= RTNH_F_LINKDOWN;
+ err = 0;
+out:
+ rcu_read_unlock();
+ return err;
+}
+
+static int fib_check_nh(struct fib_config *cfg, struct fib_nh *nh,
+ struct netlink_ext_ack *extack)
+{
+ struct net *net = cfg->fc_nlinfo.nl_net;
+ u32 table = cfg->fc_table;
+ int err;
+
+ if (nh->fib_nh_gw_family == AF_INET)
+ err = fib_check_nh_v4_gw(net, nh, table, cfg->fc_scope, extack);
+ else
+ err = fib_check_nh_nongw(net, nh, extack);
+
+ return err;
+}
+
static inline unsigned int fib_laddr_hashfn(__be32 val)
{
unsigned int mask = (fib_info_hash_size - 1);