diff options
| author | 2015-06-05 14:03:14 +0300 | |
|---|---|---|
| committer | 2015-06-07 16:33:22 +0100 | |
| commit | 6b90da4b58b39a80f490479953aa2563c3c41a6d (patch) | |
| tree | ad7f2d810aef666ee41e37a7cc878cae70053e80 /scripts/patch-kernel | |
| parent | iio: magnetometer: mmc35240: Use a smaller sleep value (diff) | |
iio: magnetometer: mmc35240: Fix sensitivity on z-axis
Datasheet says (Page 2) that typical value for sensitivity
for 16 bits mode on Z-axis is 770. Anyhow, looking at the
input driver provided by Memsic the value for MMC35240 is
1024.
Also, testing shows that using 1024 for Z-axis senzitivity
offers better results.
Fixes: abeb6b1e7b ("iio: magnetometer: Add support for MEMSIC MMC35240")
Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Diffstat (limited to 'scripts/patch-kernel')
0 files changed, 0 insertions, 0 deletions