net: hns3: fix wrong size of mailbox responding data
According to user manual, the maximum size of mailbox responding
data is 8 bytes, the macro HCLGE_MBX_MAX_RESP_DATA_SIZE
should be defined as 8 instead of 16.
Fixes: 9194d18b0577 ("net: hns3: fix the problem that the supported port is empty")