aboutsummaryrefslogtreecommitdiffstats
path: root/tools/power/x86/intel-speed-select
diff options
context:
space:
mode:
authorSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>2020-01-30 21:45:17 -0800
committerAndy Shevchenko <andriy.shevchenko@linux.intel.com>2020-02-10 17:47:38 +0200
commit14a8aa4964e01aafcd684499315d3d4ea1de428f (patch)
tree46ffcc785527410e6b6973eaa95c3e7c7cb1305c /tools/power/x86/intel-speed-select
parentplatform/x86: dell_rbu: Unify format of the printed messages (diff)
downloadlinux-dev-14a8aa4964e01aafcd684499315d3d4ea1de428f.tar.xz
linux-dev-14a8aa4964e01aafcd684499315d3d4ea1de428f.zip
tools/power/x86/intel-speed-select: Fix display for turbo-freq auto mode
When mailbox command for the turbo-freq enable fails, then don't display result for auto-mode. When turbo-freq enable fails, there is no point to set CPU priorities. Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Diffstat (limited to 'tools/power/x86/intel-speed-select')
-rw-r--r--tools/power/x86/intel-speed-select/isst-config.c5
1 files changed, 4 insertions, 1 deletions
diff --git a/tools/power/x86/intel-speed-select/isst-config.c b/tools/power/x86/intel-speed-select/isst-config.c
index 2b2b8167c65b..0cf3548681f8 100644
--- a/tools/power/x86/intel-speed-select/isst-config.c
+++ b/tools/power/x86/intel-speed-select/isst-config.c
@@ -42,6 +42,7 @@ static int out_format_json;
static int cmd_help;
static int force_online_offline;
static int auto_mode;
+static int fact_enable_fail;
/* clos related */
static int current_clos = -1;
@@ -1527,6 +1528,8 @@ static void set_fact_for_cpu(int cpu, void *arg1, void *arg2, void *arg3,
disp_results:
if (status) {
isst_display_result(cpu, outf, "turbo-freq", "enable", ret);
+ if (ret)
+ fact_enable_fail = ret;
} else {
/* Since we modified TRL during Fact enable, restore it */
isst_set_trl_from_current_tdp(cpu, fact_trl);
@@ -1568,7 +1571,7 @@ static void set_fact_enable(int arg)
NULL, &enable);
isst_ctdp_display_information_end(outf);
- if (enable && auto_mode) {
+ if (!fact_enable_fail && enable && auto_mode) {
/*
* When we adjust CLOS param, we have to set for siblings also.
* So for the each user specified CPU, also add the sibling